Spec sheet

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 40A, 1 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with a C phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Documentation & Downloads

Specifications

Key Specifications

Product Or Component Typecircuit breaker
RangePowerPact
Device Short NameBJ 040
Product NamePowerPact B
Device Applicationdistribution

Complementary

Mounting ModeI-Line
[Ics] Rated Service Breaking Capacity65 kA 220...240 V AC 50/60 Hz IEC 60947-2
Height137 mm
[Ue] Rated Operational Voltage240 V AC 50/60 Hz UL 489
Breaking Capacity CodeJ
Local Signallingpresence of auxiliary contacts flag green)
Mounting Height38.1 mm
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947-2
Circuit Breaker ApplicationHACR rated
Line Rated Current40-40 A
Breaking Capacity100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480Y/277 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 125 V DC UL 489
Mechanical Durability20000 cycles IEC 947-1 Annex K ed 5.2
Electrical Durability10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Quantity Per Setset of 1
ColorGray RAL 7016)
Depth89 mm
Network Frequency50/60 Hz
Trip Unit Technologythermal-magnetic
Connection Pitch27 mm
Tightening Torque3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
9 Mm Pitches3
Electrical ConnectionI-Line connection, line || lugs, load
Net Weight0.6375 kg
Control Typetoggle
Utilisation Categorycategory A
Continuous Current Rating80 %
[Ui] Rated Insulation Voltage800 V IEC 60947-2
Suitability For Isolationyes IEC 60947-2
Poles Description1P
Awg GaugeAWG 14...AWG 2/0 aluminium/copper
Width27 mm
Phase ConnectionC

Environment

Ik Degree Of ProtectionIK07 IEC 62262
StandardsUL 489 || NMX J-266 || GB 14048.2 || EN/IEC 60947-5-1 || CSA C22.2 No 5 || EN/IEC 60947-2 || NEMA AB1
Ip Degree Of Protectionfront cover IP40 IEC 60529
Ambient Air Temperature For Storage-50-85 °C
Ambient Air Temperature For Operation-25-70 °C
Product CertificationsUL || IEC || CCC || EAC || CSA || NOM
Pollution Degree3 IEC 60947-1
Operating Altitude< 6561.68 ft (2000 m) without derating || 5000 m with derating

Offer Sustainability

Rohs Exemption InformationYes
Environmental DisclosureENVPEP1610005EN
Pvc FreeYes
California Proposition 65WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileN/A
Halogen Content PerformanceHalogen free product
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.
Eu Rohs DirectiveCompliant with Exemptions
Circuit breaker, PowerPacT B, 40A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 40A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 40A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 40A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 40A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Loading video…

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$1166.97/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!