Carlo Gavazzi SH2DUG24 Dupline Generator 10-30 VDC, 2-DIN Housing, Max 7 Connections


Carlo Gavazzi SH2DUG24 Dupline Generator 10-30 VDC, 2-DIN Housing, Max 7 Connections
- MPN: SH2DUG24
- PPN: CLG-SH2DUG24
Spec sheet
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
CAD$484.29/ EA
Description
The master channel generator SH2DUG24 provides the channel generator output drive for a "traditional" Dupline® network in a smartDupline® system, which is controlled by the Sx2WEB24. Together with a Sx2WEB24, it substitutes a BH8-CTRLX- 230, a BH8-CTRLZ-230 or a G38x0xx master generator. Each Sx2WEB24 can be connected up to 7 master channel generators (the sum of SH2MCG24, SH2DUG24 and SH2WBU230 is 7) in order to have 7 Dupline® and smart Dupline® networks. All the devices are connected via an internal bus if they are in the same cabinet, or via terminals if they are mounted on different cabinets. Each SH2DUG24 must have an address that has to be programmed using the Sx tool.
Specifications
Dupline Specifications
- Voltage
- 8.2 V
- Minimum Dupline® voltage
- 4.5 V
- Terminal
- D+ and D (Note: The Dupline® bus is located on the upper connector and also on the local bus connector on the right side of the module.)
Maximum Dupline® voltage10 V
Maximum Dupline® current450 mA @ 25° 350 mA @ 40°
Yellow LEDs Dupline bus
- ON
- The Dupline® bus is working properly
- OFF
- The Dupline® bus is OFF or not connected.
FlashingThere is a fault on the Dupline® bus
LEDs Indication
- ON
- Supply ON
- OFF
- No communication is present on the HS bus
- Flashing
- Communication OK on HS bus
OFFSupply OFF
ONCommunication error on HS bus
HS Bus Specifications
- Bus type
- RS485 high speed bus
- Number of slave
- Max 7
- Addressing method
- The address of the SH2DUG24 is defined in the Sx tool, and then assigned to it by the Sx2WEB24 according to the SIN.
ProtocolInternal proprietary protocol
ConnectionBy local bus (left and right connectors) or terminals GND, A(-), B(+). T1, T2: termination inputs. They have to be short-circuited on the last module of the network. See wiring diagrams.
Supply Specifications
- Power supply
- Overvoltage cat. II (IEC 60664-1, par. 4.3.3.2)
- Operational voltage range
- 10 to 30 VDC (ripple included)
- Protection for reverse polarity
- Yes
- Power on delay
- Typ. 4 s
Rated operational voltage15 to 24 VDC ± 20%
Rated operational power6.5 W
Connection2xA1 (+) and 2xA2 (-)- (2 pairs of terminals internally connected)
Power off delay1 s
Downloads
CAD$484.29/ EA