Tripp Lite S3M80KX SmartOnline 3-Phase 80kVA 72kW On-Line Double-Conversion UPS, Pure Sine Wave Output









Tripp Lite S3M80KX SmartOnline 3-Phase 80kVA 72kW On-Line Double-Conversion UPS, Pure Sine Wave Output
- MPN: S3M80KX
- UPC: 037332225412
- PPN: TRP-S3M80KX
Spec sheet
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
Features
- Best-in-class footprint and power density minimize space requirements for up to 80kVA
- Intuitive LCD interface offers key performance, configuration and diagnostics info
- High efficiency (94% on-line, 98% ECO mode) helps reduce operating costs
- Optional WEBCARDLX network management card allows cost-effective remote management
- Parallel capability provides increased capacity and redundancy up to 3 units
- 2-year limited warranty
- Battery Backup and VFI Operation Protect Critical Loads
- Best-in-Class Footprint for Easy Integration into Your Network Application
- Efficient Operation and Design Reduces Cost of Ownership
- External Batteries Supply Reliable Backup with Expandable Runtime Options
- Intuitive LCD Interface Delivers Important Performance Information at a Glance
- Network Management Card Offers Remote Monitoring and Control
- Parallel Capability Provides Additional Capacity and Redundancy up to 3 Units
Specifications
- Output Volt Amp Capacity
- 80,000 VA
- Power Factor
- 0.9
- Output Voltage Regulation (Line Mode)
- +/- 1%
- Output Voltage Regulation (Battery Mode)
- +/- 1%
- Nominal Output Voltage(s) Supported
- 220/380V; 230/400V; 240/415V 3-Phase Wye
- Nominal Input Voltage(s) Supported
- 220/380V; 230/400V; 240/415V 3-Phase Wye
- Input Circuit Breakers
- 6 x 30A fuses/Phase
- THDi
- <3% (100% load)
- Battery Recharge Rate
- 9 hours to 90% (Internal batteries)
- UPS Type
- On-Line Double-Conversion
- Form Factor
- Tower
- Weight
- 112.94 kg (249 lbs)
- Storage Temperature Range
- 0 to +35°C (32 to 95°F) with battery; -15 to +60°C (5 to 140°F) without battery
- Operating Elevation
- < 1000 m (< 3280 ft); capacity de-rates 1% per 100m above 1000m
- Communications Interface
- DB9 Serial; EPO; Slot for SNMP/Web card
- Cold Start
- Supported
- Warranty
- 2-year limited warranty
- High Voltage Transfer to Battery Power (Setpoint)
- 276V (Ph-N); 478V (Ph-Ph) @ 50% or 100% load
- High Availability UPS Features
- Automatic inverter bypass; Manual bypass switch
- Grounding Lug
- Yes
- Output Receptacles
- Hardwire
- Nominal Input Voltage Description
- 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)
- LED Indicators
- 4 LEDs: BYPASS / LINE / BATTERY / FAULT modes
- Network Management Cards
- WEBCARDLX; MODBUSCARDSV; RELAYCARDSV
- External Battery Pack Compatibility
- BP480V100; BP480V100-NIB; BP480V40; BP480V40-NIB; BP480V65
- Primary UPS Height
- 1010 mm
- Primary UPS Depth
- 790 mm
Output kW Capacity72 kW
Frequency Compatibility50/60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Output Voltage Regulation (Economy Mode)+/- 11V of nominal
Output AC WaveformPure Sine Wave
Input Current (Max Load)122.2 A
Input Phase3-Phase
Power Factor (Input)0.99 PF (100% load)
Battery System Voltage+/- 240 VDC
Expandable RuntimeYes, with external battery packs
Cooling MethodFans
Dimensions (H x W x D)1010 x 360 x 790 mm (39.76 x 14.17 x 31.10 in.)
Operating Temperature Range0 to +40°C (32 to 104°F)
Relative Humidity5 to 95%, non-condensing
Audible Noise<75 dBA at 1 meter
Transfer TimeZero ms (Online to Battery, Inverter to Bypass); < 10 ms to ECO mode
CertificationsCE; IEC/EN 62040-1:2008+A1; IEC/EN 62040-2:2006 (Category C3)
Low Voltage Transfer to Battery Power (Setpoint)120V (Ph-N), 208V (Ph-Ph) @ 50% load; 176V (Ph-N), 305V (Ph-Ph) @ 100% load
SwitchesON/ENTER, OFF/ESC, TEST/UP, MUTE/DOWN buttons with multifunction controls
Communications CableDB9/RS-232 cable included
Green Energy-Saving FeaturesHigh efficiency economy mode operation
Output Capacity DetailsSupports 100% continuous load; 100-110% load for 10 min; 110-130% for 1 min; >130% for 1 sec before bypass; supports up to 3 units in parallel
Voltage Regulation DescriptionOnline double-conversion maintains output within 1% of nominal
Network Monitoring Port DescriptionSlot supports network management interface or programmable I/O relay cards
Audible AlarmMultiple audible alarms for various modes; silencing except overload & warnings
Individually Controllable Load BanksNo
Primary UPS Width360 mm
UPS Input Connection TypeHardwire