Tripp Lite SVT20KX SmartOnline 20kVA On-Line Double-Conversion UPS, 3-Phase, Tower, Pure Sine Wave






Tripp Lite SVT20KX SmartOnline 20kVA On-Line Double-Conversion UPS, 3-Phase, Tower, Pure Sine Wave
- MPN: SVT20KX
- UPC: 037332195890
- PPN: TRP-SVT20KX
Spec sheet
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
Description
Economical, entry-level 3-phase UPS system protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise.
Features
- On-line double-conversion topology, VFI operation
- Automatic and Manual Bypass for enhanced reliability
- Optional ECO mode for high-efficiency operation
- Internal batteries and expandable runtime options
- Paralleling for capacity up to 3 units
- 2-year limited warranty
- VFI True On-Line Double-Conversion 3-Phase UPS System
- Reliable Battery Backup with Expandable Runtime
- IGBT Inverter Technology
- Paralleling Capability
- Automatic and Manual Bypass
- ECO Mode
- SNMP/Web Capability
- Communications Ports
- Small-Footprint Tower Design
Specifications
Battery
- Full Load Runtime (min.)
- 4 min (18kW)
- Expandable Battery Runtime
- Supports extended runtime optional external battery packs
- DC System Voltage (VDC)
- 240
- Expandable Runtime
- Yes
Half Load Runtime (min.)11 min. (9kW)
External Battery Pack CompatibilityBP240V135
Battery Recharge Rate (Included Batteries)4 hours to 90% (Internal batteries)
Certifications
- UPS Certifications
- CE
UPS Certification DetailsEN 62040-1-1 (Safety); EN 62040-2 (Category C3)
Physical
- Cooling Method
- Fans
- Primary Form Factor
- Tower
- Primary UPS Height (mm)
- 861
- Shipping Dimensions (hwd / in.)
- 41.74 x 14.96 x 36.22
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 33.9 x 9.8 x 32
- UPS Power Module Weight (lbs.)
- 392
Installation Form Factors Supported with Included AccessoriesTower
Primary UPS Depth (mm)813
Primary UPS Width (mm)249
Shipping Weight (lbs.)427.00
UPS Power Module Dimensions (Height x Width x Depth, mm)862 x 250 x 813
UPS Power Module Weight (kg)177.81
User Interface, Alerts & Controls
- Front Panel LCD Display
- LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing)
- Audible Alarm
- Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions
SwitchesON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information)
LED Indicators4 LEDs report BYPASS / LINE / BATTERY / FAULT modes
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode
- Undervoltage Correction
- Corrects brownout conditions to 110V (50% load) / 305V (100% load)
Overvoltage CorrectionCorrects overvoltage conditions to 520V (50% load) and 478V (100% load)
Input
- Rated input current (Maximum Load)
- 34.4A
- Nominal Input Voltage Description
- 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)
- Input Circuit Breakers
- 63A (3 pole)
- Power Factor (Input)
- .99PF (100% load)
Nominal Input Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
UPS Input Connection TypeHardwire
Input Phase3-Phase
THDi<6% (100% load)
Output
- Output Volt Amp Capacity (VA)
- 20000
- Output Watt Capacity (Watts)
- 18000
- Power Factor
- 0.9
- Frequency Compatibility
- 50 / 60 Hz
- Output Voltage Regulation (Line Mode)
- +/- 1%
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Nominal Output Voltage(s) Supported
- 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
- Individually Controllable Load Banks
- No
Output kVA Capacity (kVA)20
Output kW Capacity (kW)18
Crest Factor3:1
Frequency Compatibility DetailsAutomatic frequency selection
Output Voltage Regulation (Economy Line Mode)+/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V)
Output AC Waveform (AC Mode)Pure Sine wave
Output Capacity DetailsSupports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less; Configuration options support up to 3 SVT20KX systems wired in parallel for increased capacity.
Output ReceptaclesHardwire
Communications
- Network Management Cards
- WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV
- Communications Cable
- DB9 cabling included
Network Monitoring Port DescriptionCard accessory slot also supports network interface and relay card options
Communications InterfaceDB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Environmental
- Operating Temperature Range
- 0 to +40C (32-104F)
- Relative Humidity
- 5 to 95%, non-condensing
- Audible Noise
- <65dBA front side 1M
Storage Temperature Range0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery
Operating Elevation (ft.)< 3000ft (Capacity de-rates by 1% for every 330ft over 3000)
Operating Elevation (m)< 1000m (Capacity de-rates by 1% for every 100m over 1000)
Overview
- UPC Code
- 037332195890
UPS TypeOn-Line
Special Features
- Grounding Lug
- Yes
- High Availability UPS Features
- Automatic inverter bypass; Manual bypass switch
Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
Green Energy-Saving FeaturesHigh efficiency economy mode operation
Warranty
- Product Warranty Period (International)
- 2-year limited warranty
Line / Battery Transfer
- Transfer Time
- Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode
- High Voltage Transfer to Battery Power (Setpoint)
- 520V (50% load) / 478V (100% load)
Low Voltage Transfer to Battery Power (Setpoint)110V (50% load) / 305V (100% load)