Schneider Electric LC1F225M7 TeSys F Contactor 3 Pole 225A <= 440V 220V AC Coil


Schneider Electric LC1F225M7 TeSys F Contactor 3 Pole 225A <= 440V 220V AC Coil
- MPN: LC1F225M7
- PPN: SCH-LC1F225M7
Spec sheet
Loading compare button...
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
CAD$2500.77/ EA
Description
TeSys F contactor, 3 poles (3NO), 225A/690V AC-3, for motor applications up to 110kW@400V. It provides a low sealed consumption 220V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications
Environment
- Ambient Air Temperature For Operation
- -5-55 °C
- Net Weight
- 4.75 kg
- Protective Treatment
- TH
- Operating Altitude
- 3000 m without derating
- Depth
- 181 mm
Height197 mm
Ambient Air Temperature For Storage-60-80 °C
Ip Degree Of ProtectionIP20 front face with shrouds IEC 60529 || IP20 front face with shrouds VDE 0106
Width168.5 mm
Permissible Ambient Air Temperature Around The Device-40-70 °C
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Environmental Disclosure
- ENVPEP080208EN
- Pvc Free
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
- Circularity Profile
- ENVEOLI100418
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information
Eu Rohs DirectiveCompliant with Exemptions
Complementary
- Product Certifications
- RINA || BV || CSA || UL || LROS (Lloyds register of shipping) || DNV || RMRoS || ABS || CB || UKCA
- Average Impedance
- 0.32 mOhm - Ith 315 A 50 Hz
- Control Circuit Voltage Limits
- operational 0.85...1.1 Uc 40...400 Hz 55 °C) || drop-out 0.2...0.55 Uc 40...400 Hz 55 °C)
- Mounting Support
- plate
- Contactor Coil Voltage
- 220 V AC standard
- Power Range
- 55-100 kW 200-240 V 3 phases || 110-220 kW 480-500 V 3 phases || 110-220 kW 380-440 V 3 phases
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Connections - Terminals
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit bar 2 32 x 4 mm || power circuit lugs-ring terminals 1 185-185 mm² || power circuit connector 1 185-185 mm² || power circuit bolted connection
- Motor Starter Type
- direct on-line contactor
- Maximum Operating Rate
- 2400 cyc/h 55 °C
- Tightening Torque
- control circuit 1.2 N.m || power circuit 35 N.m
- Hold-In Power Consumption In Va
- 9.9-9.9 VA, 40...400 Hz 0.9 20 °C)
- Motor Power Kw
- 110 kW at 380...400 V AC 50/60 Hz (AC-3) || 110 kW at 415 V AC 50/60 Hz (AC-3) || 110 kW at 440 V AC 50/60 Hz (AC-3) || 129 kW at 500 V AC 50/60 Hz (AC-3) || 129 kW at 660...690 V AC 50/60 Hz (AC-3) || 63 kW at 220...230 V AC 50/60 Hz (AC-3) || 40 kW at 400 V AC 50/60 Hz (AC-4)
- [Icw] Rated Short-Time Withstand Current
- 1800 A 40 °C - 10 s || 1000 A 40 °C - 30 s || 850 A 40 °C - 1 min || 560 A 40 °C - 3 min || 440 A 40 °C - 10 min
Power Dissipation Per Pole32 W AC-1 || 16 W AC-3
[Ith] Conventional Free Air Thermal Current315 A (at 40 °C)
StandardsIEC 60947-1 || JIS C8201-4-1 || EN 60947-1 || IEC 60947-4-1 || EN 60947-4-1
Control Circuit TypeAC 40...400 Hz
Rated Breaking Capacity1800 A conforming to IEC 60947-4-1
Associated Fuse Rating315 A gG at <= 440 V || 250 A aM at <= 440 V
Inrush Power In Va1070-1070 VA, 40...400 Hz 0.9 20 °C)
Pole Contact Composition3 NO
Operating Time35 ms closing at Uc) || 130 ms opening at Uc)
Mechanical Durability10 Mcycles
Compatibility CodeLC1F
Overvoltage CategoryIII
[Ui] Rated Insulation Voltage1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
Heat Dissipation8-9.8 W
Specifications
- [Uc] Control Circuit Voltage
- 220 V AC 40...400 Hz
- [Ue] Rated Operational Voltage
- <= 460 V DC || <= 690 V AC 50/60 Hz
- Product Or Component Type
- contactor
- Utilisation Category
- AC-1 || AC-4 || AC-3
- Poles Description
- 3P
Range Of ProductTeSys F
Contactor Applicationmotor control || resistive load
RangeTeSys
[Ie] Rated Operational Current315 A (at <40 °C) at <= 440 V AC-1 || 225 A (at <55 °C) at <= 440 V AC-3
Device Short NameLC1F
Downloads