Telemecanique Sensors

Telemecanique Sensors XMLR250M0T25 Electronic pressure sensors, Pressure sensors XM, XMLR 250 bar, G 1/4, 24 VDC, 4...20 mA, M12

  • MPN: XMLR250M0T25
  • PPN: TES-XMLR250M0T25
  • UNSPSC: 41111927

CAD

$602.32

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

This product is part of the XM range, an offer of pressure sensors and switches. This electronic pressure sensor is used to control and measure pressure or vacuum levels in hydraulic or pneumatic systems. It supports 4mA to 20mA analogue output. It has 4 digits 7 segments display. It supports a pressure setting range of 0bar to 250bar and maximum permissible accidental pressure of 750bar. It is furnished with 4-pin M12 male connector for electrical connection and G 1/4inch (female) for fluid connection. It is an electronic pressure sensor with a rated supply voltage of 24V DC (voltage limits 17V to 33V) and a current consumption of ≤50mA. It offers mechanical durability of about 10 million cycles. It is an IP65 and IP67 rated product. The electronic pressure sensor is made of fibreglass impregnated polyacrylamide body with 316L stainless steel fluid entry. Its dimensions are 41mm (width) x 42mm (depth) x 88mm (height) and weighs 0.186kg. This pressure switch is suitable for controlling fluids such as fresh water (0°C to 80°C), air (-20°C to 80°C), hydraulic oil (-20°C to 80°C) and refrigeration fluid (-20°C to 80°C). It is used for pressure control or monitoring on pumps. This product is certified by EAC, CULus and CE. It complies with UL 61010-1 and EN/IEC 61326-2-3 standards. One of the most comprehensive catalogues of industrial and power pressure sensors on the market, including a user-friendly electronic transmitter sensor which can be configured in complete simplicity, with unrivalled flexibility. The high precision and performance of OsiSense XMLR pressure sensors make them suitable for numerous industrial applications requiring display, control or regulation of pressure/vacuum levels.

Documentation & Downloads

Specifications

Key Specifications

Pressure Sensor Typepressure transmitter
Pressure Switch Type Of Operationpressure transmitter
Fluid Connection TypeG 1/4 (female) DIN 3852-Y
Controlled Fluidfresh water 0-80 °C) || air -20-80 °C) || hydraulic oil -20-80 °C) || refrigeration fluid -20-80 °C)
[Us] Rated Supply Voltage24 V DC SELV 17-33 V)
Device Short NameXMLR
Range Of ProductTelemecanique Pressure sensors XM
Product Or Component Typeelectronic pressure sensors
Pressure Sensor Size3620 psi || 250 bar
Maximum Permissible Accidental Pressure10875 psi || 750 bar || 75 MPa
Destruction Pressure150 MPa || 21750 psi || 1500 bar

Complementary

Display Accuracy<= 1 % of the measuring range
Height88 mm
Linearity Error<= 0.5 % of the measuring range
Display Response Time Typefast 50 ms || normal 200 ms || slow 600 ms
Drift Of The Zero Point+/- 0.1 % of measuring range/°C
Operating Positionany position, but disposals can falsified the measurement in case of upside down mounting
Net Weight0.186 kg
Maximum Delay First Up300 ms
Scale Typefixed differential
Housing Material316L stainless steel || polyacrylamide
Protection Typereverse polarity || overload protection || overvoltage protection || short-circuit protection
Width41 mm
Front Materialpolyester
Hysteresis<= 0.2 % of the measuring range
Response Time On Output<= 10 ms analog output
Electrical Connectionmale connector M12, 4 pins
Accuracy<= 1 % of the measuring range
Type Of Output Signalanalogue
Repeat Accuracy<= 0.2 % of the measuring range
Electromagnetic Compatibilitysusceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 || immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 || surge immunity test 1 kV EN/IEC 61000-4-5 || electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 || electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
Materials In Contact With Fluid316L stainless steel
Current Consumption<= 50 mA
Analogue Output Function4...20 mA
Mechanical Durability10000000 cycles
Measurement Accuracy<= 0.6 % of the measuring range
Drift Of The Sensitivity+/- 0.03 % of measuring range/°C
Display Type4 digits 7 segments
[Uimp] Rated Impulse Withstand Voltage0.5 kV DC
Depth42 mm

Environment

Product CertificationscULus || EAC
StandardsEN/IEC 61326-2-3 || UL 61010-1
MarkingCE
Ip Degree Of ProtectionIP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529
Ambient Air Temperature For Operation-20-80 °C
Shock Resistance50 gn EN/IEC 60068-2-27
Vibration Resistance20 gn 10-2000 Hz)EN/IEC 60068-2-6
Ambient Air Temperature For Storage-40-80 °C

Offer Sustainability

Rohs Exemption InformationYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Reach Free Of SvhcYes
Mercury FreeYes
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Electronic pressure sensors, Pressure sensors XM, XMLR 250 bar, G 1/4, 24 VDC, 4...20 mA, M12
Electronic pressure sensors, Pressure sensors XM, XMLR 250 bar, G 1/4, 24 VDC, 4...20 mA, M12
Electronic pressure sensors, Pressure sensors XM, XMLR 250 bar, G 1/4, 24 VDC, 4...20 mA, M12
Electronic pressure sensors, Pressure sensors XM, XMLR 250 bar, G 1/4, 24 VDC, 4...20 mA, M12
Electronic pressure sensors, Pressure sensors XM, XMLR 250 bar, G 1/4, 24 VDC, 4...20 mA, M12

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$602.32/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!