Key Specifications
- Country of Origin
- Austria, Brazil, France, Italy
Physical Attributes
- Color
- White
Important Information Attributes
- Persona Type Ids
- EU, OM, OM8
- Common Mode Rejection
- > 95 dB, > 95 dB
- Measurement Error
- < 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C, < 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C, < 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C, < 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C< 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C, < 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C, < 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C, < 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C
- Certificate Agency
- GOST-R, CSA, C-tick, cULus
- Carbon Footprint Of The End-of-life Phase [C1 To C4]
- 0.06540232869642398, 0.1 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase [A1 To A3]
- 1 kg CO2 eq., 1.380133046850267
- Local Data Status
- Publishable
- Return Indicator
- Y
- Stock Policy
- 1
- Serviceability
- No
- Field Service Division
- IDIBS
- Weee Scope
- In
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI1511026EN
- Reach Full Compliance Status Id
- NOT_CONTAINING_SVHC
- Rohs Eur In Scope
- No
- Rohs Eur Conformity Date
- 1901
- China Rohs In Scope
- Yes
- With Recycled Cardboard
- No
- Product Contributes To Saved And Avoided Emissions
- No
- Tier
- 1
- Function Option
- Advanced
- Market Segmentation
- Industrial
- Bearing Track Assembly Possible
- false
- Front Installation Possible
- false
- Isolation Between Channels And Bus
- 500 Vrms AC
- Measurement Resolution
- 0.1 °C
- Power Dissipation In W
- 1.11 W
- Product Or Component Type
- analog input module
- Radio Standard Gprs
- false
- Radio Standard Umts
- false
- Returnability
- Yes
- Software Version
- v6.2.5-6
- Supporting Protocol For Asi
- false
- Supporting Protocol For Devicenet
- false
- Supporting Protocol For Ethercat
- false
- Supporting Protocol For Interbus
- false
- Supporting Protocol For Lon
- false
- Supporting Protocol For Other Bus Systems
- false
- Supporting Protocol For Profinet Cba
- false
- Supporting Protocol For Profisafe
- false
- Supporting Protocol For Sercos
- false
- Sustainable Packaging
- No
- Total Lifecycle Carbon Footprint
- 46 kg CO2 eq.
- Vibration Resistance
- 1 gn 8.4-150 Hz) on DIN rail3.5 mm 5-8.4 Hz) on DIN rail
- Certified For Ul Hazardous Location Class I
- false
- Certified For Ul Hazardous Location Class Iii
- false
- Certified For Ul Hazardous Location Division 2
- false
- Fieldbus Connection Over Separate Bus Coupler Possible
- false
- System Accessory
- false
- Database Version
- 2024-01
- Pcr Version
- PCR-4-ed4-FR-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
- Functional-unit Description
- To manage digital or analog I/O signal 100% of the time for 10 years with dissipation power of 1.51W.
- Functional-unit Unit
- unit
- Energy Model - Manufacturing [A1-a3]
- Electricity Mix; Low voltage; 2020; Austria, AT
- Energy Model - Use [B6]
- Electricity Mix; Low voltage; 2020; Turkey, TR
- Height Nominal
- 99 mm
- [Us] Rated Supply Voltage
- 24 V DC -15...20 %
- Appendant Operation Agent (Ex Ia)
- false
- Certified For Ul Hazardous Location Group A (Acetylene)
- false
- Certified For Ul Hazardous Location Group C (Ethylene))
- false
- Certified For Ul Hazardous Location Group E (Metal Dusts)
- false
- Certified For Ul Hazardous Location Group G (Non Conductive Dust)
- false
- Performance Level According To En Iso 13849-1
- none
- Radio Standard Wi-fi 802.11
- false
- Supporting Protocol For Data-highway
- false
- Supporting Protocol For Interbus-safety
- false
- Wall Mounting/Direct Mounting Possible
- false
- Package Weight(Lbs)
- 41.0 g
- Warranty (In Months)
- 18
Environment Attributes Main
- Ambient Air Temperature For Operation
- 0-55 °C without derating horizontal installation), 0-60 °C with derating factor horizontal installation), 0-50 °C vertical installation)
- Take Back
- No
- Recycled Metal Content At Cr Level
- 0 %
- Toxic Heavy Metal Free
- Yes
- Carbon Footprint
- 46.26380832210159
- Circularity Profile
- ENVEOLI1511026EN
- Eu Rohs Directive
- Compliant
- Operating Altitude
- 0...6561.68 ft (0...2000 m)
- Packaging Without Single Use Plastic
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Pep Code
- ENVPEP1511026EN
- Pcr Version
- PCR-4-ed4-FR-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
General Attributes
- Product Or Component Type
- analog input module
ETIM
- ETIM 8
- EC001596
Output Attributes
- Analogue Output Resolution
- 12 bits
Contractual Warranty Attributes
- Warranty Period
- 18 months
Input Attributes
- Analogue Input Number
- 4
- Analogue Input Type
- temperature probe - 200...850 °C Pt 100/Pt 1000
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$833.91
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$833.91/ EA
Loading add to cart quantity...