Description
variable speed drive, Altivar Process ATV600, ATV650, 75kW, 100hp, 380...480V, IP55, UL type 12
Specifications
Communications & Management Attributes
Communication Port Protocol
Modbus serial, Ethernet
Complementary Attributes
Maximum Horse Power Rating
75 hp heavy duty, 100 hp normal duty
Maximum Thdi
<48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
Ue Rated Operational Voltage
380...480 V 75 kW 100 hp normal duty, 380...480 V 55 kW 75 hp heavy duty
Brake Chopper Integrated
false
Maximum Input Current Per Phase
131.3 A
Maximum Output Voltage
480.0 V
Maximum Acceleration Under Shock Impact During Operation
150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport
150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage
10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation
1.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport
1.5 mm at 2...13 Hz
Maximum Switching Currentrelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V ACrelay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Maximum Transient Current159 A 60 s heavy duty), 159.5 A 60 s normal duty)
Us Rated Supply Voltage380...480 V, 380...480 V - 15...10 %
Maximum Associated Fuse Rating250.0 A
Maximum Output Frequency500 kHz
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Maximum Acceleration Under Shock Load During Storage150 m/s² at 11 ms
Maximum Acceleration Under Vibrational Stress During Operation10 m/s² at 13...200 Hz
Maximum Acceleration Under Vibratory Load During Transport10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Storage1.5 mm at 2...13 Hz
Important Information Attributes
Product Contributes To Saved And Avoided Emissions
YES_SSI2, Yes
Persona Type Names
End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
Asynchronous Motor Control Profile
constant torque standard, optimized torque mode, variable torque standard
Electrical Connection
line side screw terminal 95 mm², motor screw terminal 95...120 mm², control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Frequency Resolution
analog input 0.012/50 Hz, display unit 0.1 Hz
Line Current
112.7 A 480 V normal duty), 98.9 A 380 V heavy duty), 86.9 A 480 V heavy duty), 131.3 A 380 V normal duty)
Local Signalling
3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage, 3 LEDs for local diagnostic
Motor Slip Compensation
adjustable, can be suppressed, not available in permanent magnet motor law, automatic whatever the load
Option Card
slot A communication module, PROFINET, slot A communication module, DeviceNet, slot A communication module, Modbus TCP/EtherNet/IP, slot A communication module, CANopen daisy chain RJ45, slot A communication module, CANopen SUB-D 9, slot A communication module, CANopen screw terminals, slot A/slot B digital and analog I/O extension module, slot A/slot B output relay extension module, slot A communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink, slot A communication module, Profibus DP V1
Product Destination
asynchronous motors, synchronous motors
Sampling Duration
5 ms +/- 1 ms DI5, DI6) - discrete input, 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input, 10 ms +/- 1 ms AO1) - analog output, 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Switching Frequency
2...8 kHz adjustable, 2.5...8 kHz with derating factor
class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
Carbon Footprint Of The Distribution Phase A4
13.9985280374, 14 kg CO2 eq.
Carbon Footprint Of The Installation Phase A5
14 kg CO2 eq., 13.5341074766
Carbon Footprint Of The Use Phase B2 B3 B4 B6
53 124 kg CO2 eq., 53123.748195434
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
2
Serviceability
Yes
Field Service Division
IDIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1506002EN
Reach Full Compliance Status Id
CONTAINS_SVHC
Rohs Eur In Scope
No
Rohs Eur Conformity Date
1923
China Rohs In Scope
Yes
With Recycled Cardboard
Yes
Dangerous Goods Code
LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
Tier
2
Function Option
Advanced
Market Segmentation
Industrial
1 Phase Low Current Possible
false
Application In Domestic And Commercial Area Permitted
false
Base Load Current At Low Overload
145.0 A
Capacity Of Dc Link
5600.0 µF
Data Format
8 bits, configurable odd, even or no parity
Device Short Name
ATV650
Enclosure Mounting
wall mounted
Housing Material
sheet steel
Marking
CE
Maximum Input Current Per Phase
131.3 A
Mounting Mode
wall mount
Nominal Switching Frequency
2.5 kHz
Number Of Hw Interfaces Industrial Ethernet
1
Number Of Output Phases
3
Operating Position
vertical +/- 10 degree
Overvoltage Category
III
Power Loss Per Device Current Dependent
1785.0 W
Product Availability
Non-Stock - Not normally stocked in distribution facility
Product Specific Application
process and utilities
Quantity Per Set
1
Refresh Time
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Relative Symmetric Mains Voltage Tolerance
10 %
Returnability
Yes
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Supply Frequency
50...60 Hz - 5...5 %
Supporting Protocol For Asi
false
Supporting Protocol For Can
true
Supporting Protocol For Devicenet
false
Supporting Protocol For Ethernet Ip
true
Supporting Protocol For Interbus
false
Supporting Protocol For Lon
false
Supporting Protocol For Other Bus Systems
false
Supporting Protocol For Profinet Cba
true
Supporting Protocol For Profisafe
false
Supporting Protocol For Sercos
false
Supporting Protocol For Tcp Ip
true
Total Lifecycle Carbon Footprint
54 017 kg CO2 eq.
Type Of Cooling
forced convection
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Application In Industrial Area Permitted
true
Emc Limit Value Complied
true
With Safety Function Safe Brake Management Sbc Sbt
false
With Safety Function Safe Operating Stop Sos
false
With Safety Function Safe Speed Monitor Ssm
false
With Safety Function Safe Torque Off Sto
true
With Safety Function Safely Limited Speed Sls
false
Warranty In Months
18
Database Version
2016-11
Pcr Version
PCR-ed3-EN-2015 04 02
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime, In Y
10
Energy Model - Manufacturing [A1-a3]
Energy model used: China
Energy Model - Use [B6]
Electricity Mix; AC; < 1kV; EU-27
Offer Owner Code
190786
Height Nominal
1250 mm
Persona Type IdsEU, OM, OM8, SI
Apparent Power72.2 kVA 480 V heavy duty), 93.7 kVA 480 V normal duty)
Connector TypeRJ45 on the remote graphic terminal)Modbus serial, RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Electromagnetic Compatibilityradiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Insulation Resistance> 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth> 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
Linearity ErrorAO1, AO2 +/- 0.2 % analog output, AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Motor Power Kw55 kW heavy duty), 75 kW normal duty)
Noise Level69.9 dB 86/188/EEC, 69.9 dB
Permissible Temporary Current Boost1.5 x In 60 s heavy duty), 1.1 x In 60 s normal duty)
Protection Typesafe torque off drive, motor phase break drive, thermal protection motorsafe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
Supplyinternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection, external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
Synchronous Motor Control Profilesynchronous reluctance motor, permanent magnet motor
Vibration Resistance1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
Environmental Class During Transportclass 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
Carbon Footprint Of The End Of Life Phase C1 To C417.4725560748, 17 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A3848 kg CO2 eq., 848.2671962617
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
China Rohs Label5
Without Single Use PlasticNo
Tier Id2
Function Option IdADVANCED
Market Segmentation IdINDUSTRIAL
Product Kit IdentifierN
4 Quadrant Operation Possiblefalse
Base Load Current At High Overload106.0 A
Braking To Standstillby DC injection
Computer Porttrue
Design Of Frequency ChangerU converter
Emc Filterintegrated 150 m IEC 61800-3 category C3
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Isolationbetween power and control terminals
Maximum Associated Fuse Rating250.0 A
Method Of Accessslave Modbus TCP
Network Frequency50-60 Hz
Number Of Addresses1-247 Modbus serial
Number Of Hw Interfaces Serial Rs4851
Operating Element Presenttrue
Optical Interface Presentfalse
Phase3 phase
Power Loss Static Current Independent32.0 W
Product Or Component Typevariable speed drive
Prospective Line Isc50 kA
Range Of ProductAltivar Process ATV600
Regulation Loopadjustable PID regulator
Relative Symmetric Network Frequency Tolerance5 %
Safety FunctionSTO (safe torque off) SIL 3
Software VersionEIME v5.9.1
Supporting Protocol For As Interface Safety At Workfalse
Supporting Protocol For Bacnetfalse
Supporting Protocol For Data Highwayfalse
Supporting Protocol For Devicenet Safetyfalse
Supporting Protocol For Foundation Fieldbusfalse
Supporting Protocol For Knxfalse
Supporting Protocol For Modbustrue
Supporting Protocol For Profibustrue
Supporting Protocol For Profinet Iotrue
Supporting Protocol For Safetybus Pfalse
Supporting Protocol For Suconetfalse
Sustainable PackagingNo
Transmission FrameRTU
Type Of Polarizationno impedance
With Safety Function Safe Programmable Logicfalse
Supporting Protocol For Interbus Safetyfalse
Permitted Relative Humidity During Transportclass 2K5 according to EN 60721-3
With Safety Function Safe Direction Sdifalse
With Safety Function Safe Position Spfalse
With Safety Function Safe Stop 1 Ss1false
With Safety Function Safely Limited Position Slpfalse
With Sft Fct Safe Stop 2 Ssfalse
Pep CodeENVPEP1506002EN
Pep Verification Date2021-11-01
Type Of Verification For The PepIndependent external review
Functional-unit DescriptionTo adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 90 kW electric motors for fluid management and industrial applications in IP55 conditions, at 380V to 480V rated 3-phase voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
Functional-unit Unitunit
Energy Consumption On Product Lifetime, In Kwh89977.49
Energy Model - Installation [A5]Electricity Mix; AC; < 1kV; EU-27
Energy Model - End Of Life [C1-c4]Electricity Mix; AC; < 1kV; EU-27
Pn1
Width Nominal345 mm
Environment Attributes Main
Ambient Air Temperature For Operation
-15-40 °C (without derating), -15-40 °C (without derating), -15-50 °C, -15-50 °C, 40-50 °C (with derating factor), -15-40 °C (without derating), -15-40 °C (without derating)
Ambient Air Transport Temperature
-40-70 °C, -40-70 °C
Operating Altitude
<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating1000...4800 m with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
Take Back
No
China Rohs Regulation
X
Carbon Footprint
54017.0205832844
Environmental Disclosure
ENVPEP1506002EN
Nema Degree Of Protection
NEMA 12
Packaging Without Single Use Plastic
No
Relative Humidity
5-95 % without condensation IEC 60068-2-3
Permitted Relative Humidity During Storage
class 1K5 according to EN 60721-3
Pep Verification Date
2021-11-01
Type Of Verification For The Pep
Independent external review
Ambient Air Temperature For Storage-40-70 °C, -40-70 °C
Ip Degree Of ProtectionIP55, IP55IEC 60529, IP55IEC 61800-5-1
Environmental Class During Operationclass 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Circularity ProfileENVEOLI1506002EN
Eu Rohs DirectiveCompliant By Exemption
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Permitted Relative Humidity During Operationclass 3K5 according to EN 60721-3
Pep CodeENVPEP1506002EN
Pcr VersionPCR-ed3-EN-2015 04 02
General Attributes
Phase
3 phase
Range Of Product
Altivar Process ATV600
Product Or Component Typevariable speed drive
ETIM
ETIM 8
EC001857
ETIM 9EC001857
Output Attributes
Analogue Output Type
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
Discrete Output Type
relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mArelay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA
Continuous Output Current106 A 2.5 kHz heavy duty, 145 A 2.5 kHz normal duty
Output Voltage<= power supply voltage, <= power supply voltage
Analogue Output Number2
Maximum Output Frequency500 kHz
Nominal Output Current145.0 A
Relay Output Number3
Surge Protection And Filtering Attributes
Emc Filter
integrated 150 m IEC 61800-3 category C3
Input Attributes
Analogue Input Type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits