Schneider Electric ATV650D22N4U Altivar Process Variable Speed Drive 22kW 30hp 380-480V IP55
Schneider Electric
ATV650D22N4U
Altivar Process Variable Speed Drive 22kW 30hp 380-480V IP55
MPN: ATV650D22N4U
PPN: SCH-ATV650D22N4U
UNSPSC: 39122001
Spec sheet
Loading compare button...
If you can't find the product or are unsure which one you need, please use the Product Selector tool below
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Description
The Altivar Process ATV600 variable speed drive from Schneider Electric is engineered to deliver precise control and efficiency for various industrial applications. With a robust power rating of 22 kW (30 hp) and compatibility with 380 to 480V power supplies, this drive is designed to operate seamlessly in demanding environments, boasting an IP55 rating for protection against dust and water ingress. Its advanced features include an integrated EMC filter, multiple communication protocols such as Modbus TCP, and programmable relay outputs, making it an ideal choice for automation and control systems. Additionally, the device supports a wide range of motor types, ensuring optimal performance across various applications while maintaining compliance with stringent safety and environmental standards.
<48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
Brake Chopper Integrated
false
Maximum Input Current Per Phase
39.6 A
Maximum Output Voltage
480.0 V
Maximum Switching Currentrelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Maximum Transient Current58.8 A 60 s heavy duty), 50.9 A 60 s normal duty)
Maximum Associated Fuse Rating80.0 A
Maximum Output Frequency500 kHz
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Important Information Attributes
Product Contributes To Saved And Avoided Emissions
YES_SSI2, Yes
Persona Type Names
End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
Asynchronous Motor Control Profile
constant torque standard, optimized torque mode, variable torque standard
Electrical Connection
line side screw terminal 10...16 mm², motor screw terminal 16 mm², control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
EMC Filter
integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Insulation Resistance
> 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
Linearity Error
AO1, AO2 +/- 0.2 % analog output, AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Motor Power KW
18.5 kW heavy duty), 22 kW normal duty)
Noise Level
53.7 dB 86/188/EEC, 53.7 dB
Permissible Temporary Current Boost
1.5 x In 60 s heavy duty), 1.1 x In 60 s normal duty)
Protection Type
safe torque off drive, motor phase break drive, thermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
Supply
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection, external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
Synchronous Motor Control Profile
synchronous reluctance motor, permanent magnet motor
Vibration Resistance
1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
Us Rated Supply Voltage2
380...480 V, 380...480 V - 15...10 %
Environmental Class During Storage2
class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
Carbon Footprint Of The Distribution Phase A4
4.1157695915, 4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A5
7 kg CO2 eq., 7.4225612083
Carbon Footprint Of The Use Phase B2 B3 B4 B6
19 436 kg CO2 eq., 19435.5047572401
Environmental Class During Storage3
class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
Ue Rated Operational Voltage5
380...480 V 22 kW 30 hp normal duty, 380...480 V 18.5 kW 20 hp heavy duty
Local Publishable Date
2026-01-12
Serviceability
Yes
Field Service Division
IDIBS
Legacy WEEE Scope
In
EOLI Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
ROHS EUR Status
Compliant with Exemptions
ROHS EUR Full Compliance Status Id
PRO_ACTIVE_COMPLIANCE
Green Premium Status For Reporting
Green Premium product
Without Single Use Plastic
No
Dangerous Goods Code
LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
Function Option
Advanced
Market Segmentation
Industrial
4 Quadrant Operation Possible
false
Base Load Current At High Overload
39.2 A
Braking To Standstill
by DC injection
Computer Port
true
Design Of Frequency Changer
U converter
Enclosure Mounting
wall mounted
Housing Material
plastic
Marking
CE
Maximum Input Current Per Phase
39.6 A
Mounting Mode
wall mount
Nominal Switching Frequency
4 kHz
Operating Element Present
true
Optical Interface Present
false
Package Weight Lbs
25.0 kg
Power Loss Per Device Current Dependent
670.0 W
Product Availability
Non-Stock - Not normally stocked in distribution facility
Product Specific Application
process and utilities
Range Of Product
Altivar Process ATV600
Regulation Loop
adjustable PID regulator
Relative Symmetric Network Frequency Tolerance
5 %
Safety Function
STO (safe torque off) SIL 3
Supply Frequency
50...60 Hz - 5...5 %
Supporting Protocol For Asi
false
Supporting Protocol For Can
true
Supporting Protocol For Devicenet
false
Supporting Protocol For Ethernet Ip
true
Supporting Protocol For Interbus
false
Supporting Protocol For Lon
false
Supporting Protocol For Other Bus Systems
false
Supporting Protocol For Profinet Cba
true
Supporting Protocol For Profisafe
false
Supporting Protocol For Sercos
false
Supporting Protocol For TCP IP
true
Total Lifecycle Carbon Footprint
19 676 kg CO2 eq.
Type Of Cooling
forced convection
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Emc Limit Value Complied2
true
Maximum Acceleration Under Shock Load During Storage2
150 m/s² at 11 ms
Maximum Acceleration Under Vibrational Stress During Operation2
10 m/s² at 13...200 Hz
Maximum Acceleration Under Vibratory Load During Transport2
10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Storage2
1.5 mm at 2...13 Hz
Permitted Relative Humidity During Operation2
class 3K5 according to EN 60721-3
Permitted Relative Humidity During Transport2
class 2K5 according to EN 60721-3
With Safety Function Safe Direction Sdi2
false
With Safety Function Safe Position Sp2
false
With Safety Function Safe Stop 1 SS1
false
With Safety Function Safely Limited Position Slp2
false
With Sft Fct Safe Stop 2 Ss
false
Supporting Protocol For Interbus Safety
false
Stocking Flag
Y
Emc Limit Value Complied3
true
Maximum Acceleration Under Shock Load During Storage3
150 m/s² at 11 ms
Maximum Acceleration Under Vibrational Stress During Operation3
10 m/s² at 13...200 Hz
Maximum Acceleration Under Vibratory Load During Transport3
10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Storage3
1.5 mm at 2...13 Hz
Permitted Relative Humidity During Operation3
class 3K5 according to EN 60721-3
Permitted Relative Humidity During Transport3
class 2K5 according to EN 60721-3
With Safety Function Safe Direction Sdi3
false
With Safety Function Safe Position Sp3
false
With Safety Function Safe Torque Off Sto3
true
With Safety Function Safely Limited Speed Sls3
false
Pep Code
ENVPEP1406001EN
Pep Verification Date
2021-11-01
Type Of Verification For The Pep
Independent external review
Functional Unit Description
To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 22 kW electric motors for fluid management and industrial applications in IP55/UL type 1 conditions, at 380V to 480V rated 3-phase voltage supply, with disconnect switch. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
Energy Model Manufacturing A1 A3 2
Energy model used: China
Energy Model Use B6 2
Electricity Mix; AC; < 1kV; EU-27
Global Commercial Status
Commercialised
With Safety Function Safe Stop 1 Ss1 5
false
Persona Type IdsEU, OM, OM8, SI
Apparent Power24.9 kVA 480 V heavy duty), 28.6 kVA 480 V normal duty)
Connector TypeRJ45 on the remote graphic terminal)Modbus serial, RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Electromagnetic Compatibilityradiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Frequency Resolutionanalog input 0.012/50 Hz, display unit 0.1 Hz
Line Current34.4 A 480 V normal duty), 34.1 A 380 V heavy duty), 29.9 A 480 V heavy duty), 39.6 A 380 V normal duty)
Local Signalling3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage, 3 LEDs for local diagnostic
Motor Slip Compensationadjustable, can be suppressed, not available in permanent magnet motor law, automatic whatever the load
Option Cardslot A communication module, PROFINET, slot A communication module, DeviceNet, slot A communication module, Modbus TCP/EtherNet/IP, slot A communication module, CANopen daisy chain RJ45, slot A communication module, CANopen SUB-D 9, slot A communication module, CANopen screw terminals, slot A/slot B digital and analog I/O extension module, slot A/slot B output relay extension module, slot A communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink, slot A communication module, Profibus DP V1
Sampling Duration5 ms +/- 1 ms DI5, DI6) - discrete input, 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input, 10 ms +/- 1 ms AO1) - analog output, 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Switching Frequency4...12 kHz with derating factor, 2...12 kHz adjustable
Ue Rated Operational Voltage2380...480 V 22 kW 30 hp normal duty, 380...480 V 18.5 kW 20 hp heavy duty
Environmental Class During Operation2class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
Environmental Class During Transport2class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
Carbon Footprint Of The End Of Life Phase C1 To C45.641489052, 6 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A3223 kg CO2 eq., 223.008020958
Environmental Class During Operation3class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
Environmental Class During Transport3class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
Local Data StatusPublishable
Device TypeVariable speed drive - VSD Compacts
TraceabilityYes
Average Life Duration10 year(s)
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1406001EN
Reach Full Compliance Status IdCONTAINS_SVHC
ROHS EUR In ScopeNo
ROHS EUR Full Compliance StatusPro-active compliance (Product out of EU RoHS legal scope)
China ROHS In ScopeYes
With Recycled CardboardYes
Return IndicatorY
Function Option IdADVANCED
Market Segmentation IdINDUSTRIAL
1 Phase Low Current Possiblefalse
Application In Domestic And Commercial Area Permittedfalse
Base Load Current At Low Overload46.3 A
Capacity Of Dc Link1500.0 µF
Data Format8 bits, configurable odd, even or no parity
Device Short NameATV650
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Isolationbetween power and control terminals
Maximum Associated Fuse Rating80.0 A
Method Of Accessslave Modbus TCP
Network Frequency50-60 Hz
Number Of Addresses1-247 Modbus serial
Operating Positionvertical +/- 10 degree
Overvoltage CategoryIII
Phase3 phase
Power Loss Static Current Independent23.0 W
Product Or Component Typevariable speed drive
Prospective Line Isc50 kA
Refresh Timerelay output R1, R2, R3)5 ms +/- 0.5 ms)
Relative Symmetric Mains Voltage Tolerance10 %
ReturnabilityYes
Shock Resistance15 gn 11 ms IEC 60068-2-27
Supporting Protocol For As Interface Safety At Workfalse
Supporting Protocol For Bacnetfalse
Supporting Protocol For Data Highwayfalse
Supporting Protocol For Devicenet Safetyfalse
Supporting Protocol For Foundation Fieldbusfalse
Supporting Protocol For Knxfalse
Supporting Protocol For Modbustrue
Supporting Protocol For Profibustrue
Supporting Protocol For Profinet Iotrue
Supporting Protocol For Safetybus Pfalse
Supporting Protocol For Suconetfalse
Sustainable PackagingNo
Transmission FrameRTU
Type Of Polarizationno impedance
With Safety Function Safe Programmable Logicfalse
Maximum Acceleration Under Shock Impact During Operation2150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport2150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage210 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation21.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport21.5 mm at 2...13 Hz
Permitted Relative Humidity During Storage2class 1K5 according to EN 60721-3
With Safety Function Safe Brake Management Sbc Sbt2false
With Safety Function Safe Operating Stop Sos2false
With Safety Function Safe Speed Monitor Ssm2false
With Safety Function Safe Torque Off Sto2true
With Safety Function Safely Limited Speed Sls2false
Application In Industrial Area Permittedtrue
Medium Descvariable speed drive, Altivar Process ATV600, ATV650, 22kW, 30hp, 380...480V, IP55, UL type 12
Product Kit IdentifierN
Maximum Acceleration Under Shock Impact During Operation3150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport3150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage310 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation31.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport31.5 mm at 2...13 Hz
Permitted Relative Humidity During Storage3class 1K5 according to EN 60721-3
With Safety Function Safe Brake Management Sbc Sbt3false
With Safety Function Safe Operating Stop Sos3false
With Safety Function Safe Speed Monitor Ssm3false
With Safety Function Safely Limited Position Slp3false
With Sft Fct Safe Stop 2 Ss4false
Database Version2016-11
Pcr VersionPCR-ed3-EN-2015 04 02
Data Sourceextrapolated product
Functional Unit UnitUnit
Energy Model Installation A5 2Electricity Mix; AC; < 1kV; EU-27
Energy Model End Of Life C1 C4 2Electricity Mix; AC; < 1kV; EU-27
Us Rated Supply Voltage5380...480 V - 15...10 %
Environment Attributes Main
Take Back
Nej, No
Ambient Air Transport Temperature
-40-70 °C, -40-70 °C
IP Degree Of Protection
IP55, IP55IEC 60529, IP55IEC 61800-5-1
ROHS Exemption Information
Yes
China ROHS Regulation
X
Carbon Footprint
19675.69259805
Circularity Profile
ENVEOLI1406001EN
Nema Degree Of Protection
NEMA 12
Packaging Without Single Use Plastic
No
Relative Humidity
5-95 % without condensation IEC 60068-2-3
Pep Verification Date
2021-11-01
Type Of Verification For The Pep
Independent external review
Ambient Air Temperature For Operation-15-40 °C (without derating), -15-40 °C (without derating), -15-50 °C, 40-50 °C (with derating factor), -15-40 °C (without derating), -15-40 °C (without derating)
EU ROHS DirectiveCompliant By Exemption , Pro-active compliance (Product out of EU RoHS legal scope)
Operating Altitude<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 1000...4800 m with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Temperature For Storage-40-70 °C
Environmental DisclosureENVPEP1406001EN
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep CodeENVPEP1406001EN
Pcr VersionPCR-ed3-EN-2015 04 02
General Attributes
Phase
3 phase
Range Of Product
Altivar Process ATV600
Product Or Component Typevariable speed drive
Output Attributes
Analogue Output Type
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
Discrete Output Type
relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mA, relay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA
Analogue Output Number
2
Maximum Output Frequency
500 kHz
Nominal Output Current
46.3 A
Output Voltage
<= power supply voltage
Speed Drive Output Frequency
0.1-500 Hz
Continuous Output Current39.2 A 4 kHz heavy duty, 46.3 A 4 kHz normal duty
integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Input Attributes
Analogue Input Type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits