Schneider Electric ATV950U30N4EU Variable Speed Drive 3kW 380-480V IP55 UL Type 12


Schneider Electric ATV950U30N4EU Variable Speed Drive 3kW 380-480V IP55 UL Type 12
- MPN: ATV950U30N4EU
- PPN: SCH-ATV950U30N4EU
Spec sheet
Loading compare button...
Available to Order
Company Stock:
0
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
CAD$2331.29/ EA
Description
The Altivar Process ATV900 variable speed drive from Schneider Electric is engineered for robust industrial applications, offering a powerful 3kW output across a voltage range of 380 to 480V. With an IP55 rating, this drive is designed to withstand harsh environments, featuring chemical and dust pollution resistance, making it ideal for demanding conditions. Its advanced control capabilities, including Modbus TCP communication and configurable relay outputs, allow for precise motor management and integration into various automation systems. Additionally, the drive incorporates essential safety functions such as Safe Torque Off and Safe Stop, ensuring reliable operation while protecting both equipment and personnel.
Specifications
Communications & Management Attributes
- Communication Port Protocol
- Modbus TCP, Modbus serial, EtherNet/IP
Complementary Attributes
- Maximum Switching Current
- relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DCrelay output R1 resistive, cos phi = 1 3 A 250 V AC, relay output R1 resistive, cos phi = 1 3 A 30 V DC, relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
- Maximum Transient Current
- 8.6 A 60 s normal duty), 8.4 A 60 s heavy duty)
- Us Rated Supply Voltage
- 380...480 V, 380...480 V - 15...10 %
- Maximum Associated Fuse Rating
- 12.0 A
- Maximum Output Frequency
- 599 Hz
- Minimum Switching Current
- relay output R1, R2, R3 5 mA 24 V DC
- Maximum Acceleration Under Shock Load During Storage
- 150 m/s² at 11 ms
- Maximum Acceleration Under Vibrational Stress During Operation
- 10 m/s² at 13...200 Hz
- Maximum Acceleration Under Vibratory Load During Transport
- 10 m/s² at 13...200 Hz
- Maximum Deflection Under Vibratory Load During Storage
- 1.5 mm at 2...13 Hz
Maximum Thdi<48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12, <48 % full load IEC 61000-3-12
Ue Rated Operational Voltage380...480 V 3.0 kW normal duty, 380...480 V 2.2 kW heavy duty
Brake Chopper Integratedtrue
Maximum Input Current Per Phase5.8 A
Maximum Output Voltage480.0 V
Maximum Acceleration Under Shock Impact During Operation150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation1.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport1.5 mm at 2...13 Hz
Important Information Attributes
- Persona Type Ids
- EU, OM, OM8, SI
- Apparent Power
- 4.2 kVA 480 V normal duty), 3.3 kVA 480 V heavy duty)
- Connector Type
- 2 RJ45, 1 RJ45
- Electrical Connection
- control screw terminal 0.5...1.5 mm², line side screw terminal 4...6 mm², motor screw terminal 4...6 mm², DC bus screw terminal 2.5...6 mm²
- Emc Filter
- integrated, with EMC plate option
- Line Current
- 5.8 A 380 V normal duty), 4.5 A 380 V heavy duty), 5.1 A 480 V normal duty), 4.0 A 480 V heavy duty)
- Motor Power Kw
- 3.0 kW normal duty, 2.2 kW heavy duty
- Noise Level
- 52 dB 86/188/EEC, 52 dB
- Product Destination
- asynchronous motors, synchronous motors
- Sampling Duration
- 2 ms +/- 0.5 ms DI1...DI8) - discrete input, 5 ms +/- 1 ms DI7, DI8) - pulse input, 1 ms +/- 1 ms AI1, AI2, AI3) - analog input, 5 ms +/- 1 ms AQ1, AQ2) - analog output
- Synchronous Motor Control Profile
- permanent magnet motor, synchronous reluctance motor
- Type Of Polarization
- no impedance, no impedance Modbus serial
- Environmental Class During Transport
- class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
- Carbon Footprint Of The End Of Life Phase C1 To C4
- 3.0492179262, 3 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase A1 To A3
- 188 kg CO2 eq., 188.1961775044
- Certificate Agency
- ATEX INERIS, Bureau Veritas, TÜV, UL, CSA, DNV-GL, ABS
- Local Publishable Date
- 2026-01-12
- Stocking Flag
- Y
- Device Type
- Variable speed drive - VSD Compacts
- Traceability
- Yes
- Average Life Duration
- 10 year(s)
- Weee Product Category
- 4
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Reference contains Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Reference contains Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant By Exemption
- Rohs Eur Full Compliance Status
- Compliant By Exemption
- China Rohs Label
- 5
- Without Single Use Plastic
- No
- Dangerous Goods Code
- LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
- Tier
- 2
- Function Option
- Advanced
- Market Segmentation
- Industrial
- 1 Phase Low Current Possible
- false
- Application In Domestic And Commercial Area Permitted
- false
- Base Load Current At High Overload
- 5.6 A
- Braking To Standstill
- by DC injection
- Design Of Frequency Changer
- U converter
- Exchange Mode
- half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
- Isolation
- between power and control terminals
- Maximum Associated Fuse Rating
- 12.0 A
- Method Of Access
- slave Modbus TCP
- Network Frequency
- 50-60 Hz
- Number Of Hw Interfaces Industrial Ethernet
- 2
- Number Of Output Phases
- 3
- Operating Position
- vertical +/- 10 degree
- Overvoltage Category
- III
- Power Loss Per Device Current Dependent
- 119.0 W
- Product Availability
- Non-Stock - Not normally stocked in distribution facility
- Product Specific Application
- process for industrial
- Quantity Per Set
- 1
- Refresh Time
- relay output R1, R2, R3)5 ms +/- 0.5 ms)
- Relative Symmetric Mains Voltage Tolerance
- 10 %
- Returnability
- Yes
- Supporting Protocol For As Interface Safety At Work
- false
- Supporting Protocol For Bacnet
- false
- Supporting Protocol For Data Highway
- false
- Supporting Protocol For Devicenet Safety
- false
- Supporting Protocol For Foundation Fieldbus
- false
- Supporting Protocol For Knx
- false
- Supporting Protocol For Modbus
- true
- Supporting Protocol For Profibus
- true
- Supporting Protocol For Profinet Io
- true
- Supporting Protocol For Safetybus P
- false
- Supporting Protocol For Suconet
- false
- Sustainable Packaging
- No
- Transmission Frame
- RTU
- With Safety Function Safe Programmable Logic
- false
- Supporting Protocol For Interbus Safety
- false
- Permitted Relative Humidity During Transport
- class 2K5 according to EN 60721-3
- With Safety Function Safe Direction Sdi
- false
- With Safety Function Safe Position Sp
- false
- With Safety Function Safe Stop 1 Ss1
- true
- With Safety Function Safely Limited Position Slp
- false
- With Sft Fct Safe Stop 2 Ss
- false
- Pep Code
- ENVPEP1508009EN
- Pep Verification Date
- 2021-11-01
- Type Of Verification For The Pep
- Independent external review
- Functional-unit Description
- To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 5,5 kW electric motors for fluid management and industrial applications in IP55 conditions, at 380V to 480V rated 3-phase voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime, In Kwh
- 6486.079
- Energy Model - Installation [A5]
- Electricity Mix; AC; < 1kV; EU-27
- Energy Model - End Of Life [C1-c4]
- Electricity Mix; AC; < 1kV; EU-27
- Pn
- 1
- Width Nominal
- 264 mm
Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
Asynchronous Motor Control Profileconstant torque standard, optimized torque mode, variable torque standard
Data Format8 bits, configurable odd, even or no parity Modbus serial, 8 bits, configurable odd, even or no parity
Electromagnetic Compatibilityelectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Encoder Protocol1 Vpp, EnDat 2.2, resolver, RS 422, SSI 24V, SSI 5V, TTL/HTL
Linearity ErrorAI1, AI2, AI3 +/- 0.15 % of maximum value analog input, AQ1, AQ2 +/- 0.2 % analog output
Motor Slip Compensationcan be suppressed, adjustable, not available in permanent magnet motor law, automatic whatever the load
Number Of Addresses1-247, 1-247 Modbus serial
Protection Typesafe torque off drive, motor phase break drivethermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
Switching Frequency2...16 kHz adjustable, 4...16 kHz with derating factor
Transmission Rate10/100 Mbit/s Ethernet IP/Modbus TCP, 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial, 10, 100 Mbits, 4.8 kbps, 9600 bit/s, 19200 bit/s
Environmental Class During Storageclass 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
Carbon Footprint Of The Distribution Phase A42.9840663445, 3 kg CO2 eq.
Carbon Footprint Of The Installation Phase A57 kg CO2 eq., 7.4489630931
Carbon Footprint Of The Use Phase B2 B3 B4 B63 830 kg CO2 eq., 3829.511571697
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionIDIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1508009EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeNo
Rohs Eur Conformity Date1923
China Rohs In ScopeYes
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier Id2
Function Option IdADVANCED
Market Segmentation IdINDUSTRIAL
Product Kit IdentifierN
4 Quadrant Operation Possibletrue
Assembly Styleenclosed
Base Load Current At Low Overload7.2 A
Computer Porttrue
Device ApplicationIndustrial Application
Housing Materialplastic
MarkingCE
Maximum Input Current Per Phase5.8 A
Mounting Modewall mount
Nominal Switching Frequency4 kHz
Number Of Hw Interfaces Serial Rs4851
Operating Element Presenttrue
Optical Interface Presentfalse
Phase3 phase
Power Loss Static Current Independent14.0 W
Product Or Component Typevariable speed drive
Prospective Line Isc50 kA
Range Of ProductAltivar Process ATV900
Regulation Loopadjustable PID regulator
Relative Symmetric Network Frequency Tolerance5 %
Software VersionEIME v5.9.1
Supporting Protocol For Asifalse
Supporting Protocol For Cantrue
Supporting Protocol For Devicenetfalse
Supporting Protocol For Ethernet Iptrue
Supporting Protocol For Interbusfalse
Supporting Protocol For Lonfalse
Supporting Protocol For Other Bus Systemsfalse
Supporting Protocol For Profinet Cbatrue
Supporting Protocol For Profisafefalse
Supporting Protocol For Sercosfalse
Supporting Protocol For Tcp Iptrue
Total Lifecycle Carbon Footprint4 031 kg CO2 eq.
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Application In Industrial Area Permittedtrue
Emc Limit Value Compliedtrue
With Safety Function Safe Brake Management Sbc Sbttrue
With Safety Function Safe Operating Stop Sosfalse
With Safety Function Safe Speed Monitor Ssmfalse
With Safety Function Safe Torque Off Stotrue
With Safety Function Safely Limited Speed Slstrue
Warranty In Months18
Database Version2016-11
Pcr VersionPCR-ed3-EN-2015 04 02
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime, In Y10
Energy Model - Manufacturing [A1-a3]Energy model used: Indonesia
Energy Model - Use [B6]Electricity Mix; AC; < 1kV; EU-27
Offer Owner Code190786
Height Nominal678 mm
Environment Attributes Main
- Ambient Air Temperature For Operation
- -15-40 °C (without derating), -15-40 °C (without derating), -15-50 °C, -15-50 °C, -15-40 °C (without derating), -15-40 °C (without derating), 40-50 °C (with derating factor)
- Ambient Air Transport Temperature
- -40-70 °C, -40-70 °C
- Environmental Class During Operation
- class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
- Recycled Metal Content At Cr Level
- 0 %
- Mercury Free
- Yes
- Circularity Profile
- ENVEOLI1508009EN
- Eu Rohs Directive
- Compliant By Exemption
- Packaging Made With Recycled Cardboard
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Permitted Relative Humidity During Storage
- class 1K5 according to EN 60721-3
- Pep Verification Date
- 2021-11-01
- Type Of Verification For The Pep
- Independent external review
Ambient Air Temperature For Storage-40-70 °C, -40-70 °C
Operating Altitude<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 1000...4800 m with current derating 1 % per 100 m
Take BackNo
China Rohs RegulationX
Carbon Footprint4031.1899965652
Environmental DisclosureENVPEP1508009EN
Ip Degree Of ProtectionIP55
Packaging Without Single Use PlasticNo
Permitted Relative Humidity During Operationclass 3K5 according to EN 60721-3
Pep CodeENVPEP1508009EN
Pcr VersionPCR-ed3-EN-2015 04 02
General Attributes
- Phase
- 3 phase
- Range Of Product
- Altivar Process ATV900
Product Or Component Typevariable speed drive
ETIM
- ETIM 8
- EC001857
ETIM 9EC001857
Output Attributes
- Analogue Output Type
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
- Discrete Output Type
- logic output DQ+ 0-1 kHz <= 30 V DC 100 mA, programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA, logic output DQ- 0-1 kHz <= 30 V DC 100 mA
- Analogue Output Number
- 2
- Maximum Output Frequency
- 599 Hz
- Nominal Output Current
- 7.2 A
- Relay Output Number
- 3
Continuous Output Current7.2 A 4 kHz normal duty, 5.6 A 4 kHz heavy duty
Relay Output Typeconfigurable relay logic R1 fault relay NO/NC 100000 cycles, configurable relay logic R2 sequence relay NO 1000000 cycles, configurable relay logic R3 sequence relay NO 1000000 cycles
Discrete Output Number2
Maximum Output Voltage480.0 V
Nominal Output Power3.0 W
Surge Protection And Filtering Attributes
- Emc Filter
- integrated, with EMC plate option
Input Attributes
- Analogue Input Type
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
- Input Compatibility
- DI1...DI8 discrete input level 1 PLC IEC 61131-2, DI7, DI8 pulse input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2
- Discrete Input Logic
- 16 preset speeds
- Number Of Input Phases
- 3
Discrete Input TypeDI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm, DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V), STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Analogue Input Number3
Discrete Input Number10
Specifications
- Country of Origin
- China
Depth300 mm
Batteries & Runtime Attributes
- Removable Battery
- Yes
Downloads
Similar Products
CAD$2331.29/ EA
Loading add to cart quantity...