TeSys Deca Contactor 3P 115A 230V AC Coil 120mm Width
TeSys Deca Contactor 3P 115A 230V AC Coil 120mm Width
Schneider Electric

Schneider Electric LC1D115P7 TeSys Deca Contactor 3P 115A 230V AC Coil 120mm Width

  • MPN: LC1D115P7
  • PPN: SCH-LC1D115P7

CAD

$1054.02

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 115A/1000V AC-3 (55kW@400V). They can be used to create motor starters for almost any type of application. It provides a 230V 50/60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirrror certified), power connection by screw connectors 2 inputs, control connection by screw clamp terminals. For operating rates until 2400 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (120mm width), mounting on 2 DIN-rails or screw fixing. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, Czechia, France, Indonesia
Depth136 mm

Complementary Attributes

Control Circuit Type
AC 50/60 Hz standard
Irms Rated Making Capacity
1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Operating Rate
2400 cyc/h at 60 °C
Minimum Switching Voltage
17 V for signalling circuit
Control Circuit Voltage Limits0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz1...1.15 Uc (55-70 °C):operational AC 50/60 Hz
Maximum Horse Power Rating30 hp at 200/208 V AC 50/60 Hz for 3 phase motors40 hp at 230/240 V AC 50/60 Hz for 3 phase motors75 hp at 460/480 V AC 50/60 Hz for 3 phase motors100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947

Important Information Attributes

Persona Type Ids
EU, OM, OM8, PB
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Contactor Application
motor control, resistive load
Inrush Power In Va
280-350 VA 60 Hz cos phi 0.8 (at 20 °C), 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 6 Gn for 11 ms)
Mounting Support
rail, plate
Tightening Torque
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Certificate Agency
UL, CSA, CCC, UKCA, CE, EAC, Marine
[Ui] Rated Insulation Voltage
signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
Hold-in Power Consumption In Va
2-18 VA 60 Hz cos phi 0.3 (at 20 °C), 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
Carbon Footprint Of The Distribution Phase [A4]
0.71114, 0.7 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]
0.3 kg CO2 eq., 0.25139
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
81 kg CO2 eq., 81.355
Local Publishable Date
2026-07-12
Stocking Flag
N
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Use Carbon Footprint
81.355
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI100405EN
Reach Full Compliance Status Id
CONTAINS_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
1904
China Rohs In Scope
No
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Average Impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Compatibility Code
LC1D
Device Short Name
LC1D
Flame Retardance
V1 conforming to UL 94
Mechanical Durability
8 Mcycles
Operating Time
6...20 ms opening20...50 ms closing
Pole Contact Composition
3 NO
Product Or Component Type
contactor
Range
TeSys
Returnability
Yes
Signalling Circuit Frequency
25...400 Hz
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep Code
ENVPEP0603001EN
Pep Verification Date
2025-11-10
Psr Version
PSR-0005-ed2-2016 03 29
Data Source
referent product
Functional-unit Quantity
1
Reference Lifetime In Y
20
Energy Model - Installation [A5]
Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]
Electricity Mix; Production mix; Low voltage; FR
Height Nominal
158 mm
[Icw] Rated Short-time Withstand Current
250 A 40 °C - 10 min for power circuit550 A 40 °C - 1 min for power circuit950 A 40 °C - 10 s for power circuit1100 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Uc] Control Circuit Voltage
230 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947
Package Weight(Lbs)
2.537 kg
Warranty (In Months)
18
Climate Change - Biogenics ( Kg Co2 Eq.) Manufacturing [A1-a3]
2.7717
Climate Change - Fossil Fuels ( Kg Co2 Eq.) Manufacturing [A1-a3]
18.28
Climate Change - Fossil Fuels ( Kg Co2 Eq.) End Of Life [C1-c4]
4.1309
Climate Change - Total ( Kg Co2 Eq.) Manufacturing [A1-a3]
21.052
Climate Change - Total ( Kg Co2 Eq.) End Of Life [C1-c4]
4.1915
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3]
379.16
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Installation [A5]
2.6167
Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4]
199.36
Ecotoxicity (Fresh Water) (Ctue) Manufacturing [A1-a3]
2873.1
Ecotoxicity (Fresh Water) (Ctue) Installation [A5]
1.7156
Ecotoxicity (Fresh Water) (Ctue) End Of Life [C1-c4]
221.51
Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3]
193.93
Hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D]
-1171
Impacts Related To Land Use/Soil Quality (-) Operational Energy Use [B6]
2.5934
Ionizing Radiation Human Health (Kbq Of U235 Equiv.) Manufacturing [A1-a3]
27507
Ionizing Radiation Human Health (Kbq Of U235 Equiv.) Benefits/Loads Beyond System Boundaries [D]
-1495.2
Net Use Of Fresh Water (M3) Benefits/Loads Beyond System Boundaries [D]
-1.1882
Non-hazardous Waste Disposed Of (Kg) Installation [A5]
0.8178
Non-hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D]
-21.547
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3]
25.501
Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3]
394.45
Total Use Of Primary Energy During The Life Cycle (Mj) Installation [A5]
2.8045
Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4]
200.82
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3]
15.286
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4]
1.4624
Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
25.501
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]
353.66
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Installation [A5]
2.6167
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4]
199.36
Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
2.7395
Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D]
-2.4402
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6]
1444.3
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D]
-24.473
Water Use (M3 Eq) Operational Energy Use [B6]
5.8924
Water Use (M3 Eq) Benefits/Loads Beyond System Boundaries [D]
-51.034
Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
Market SegmentationCommercial, Industrial
Electrical Durability0.8 Mcycles 200 A AC-1 <= 440 V, 0.95 Mcycles 115 A AC-3 <= 440 V, 0.95 Mcycles 115 A AC-3e <= 440 V
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw55 kW at 380/400 V AC 50/60 Hz (AC-3e), 59 kW at 415/440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 660/690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e), 30 kW at 220/230 V AC 50/60 Hz (AC-3)55 kW at 380/400 V AC 50/60 Hz (AC-3)59 kW at 415/440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660/690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3), 30 kW at 220/230 V AC 50/60 Hz (AC-3e), 18.5 kW at 400 V AC 50/60 Hz (AC-4)
Power Dissipation Per Pole24 W AC-17.9 W AC-3, 7.9 W AC-3e
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
[Ie] Rated Operational Current200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Connections - Terminalscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable endpower circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable endpower circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable endpower circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable endpower circuit: connector 1 10-120 mm² - cable stiffness: solid without cable endpower circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]4.1915, 4 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]21 kg CO2 eq., 21.052
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Manufacturing Carbon Footprint21.052
End Of Life Carbon Footprint4.1915
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Associated Fuse Rating250 A gG at <= 690 V coordination type 1 for power circuit200 A gG at <= 690 V coordination type 2 for power circuit10 A gG for signalling circuit
Coil Technologybuilt-in bidirectional peak limiting diode suppressor
Contact CompatibilityM13
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation3-8 W at 50/60 Hz
Number Of Poles3P
Overvoltage CategoryIII
Product AvailabilityStock - Normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 684932 cycles contactor with nominal load EN/ISO 13849-1B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv5.9.4
Total Lifecycle Carbon Footprint108 kg CO2 eq.
Control Circuit Voltage 18 Control Circuit Voltage230 V
Database Version2022-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionSwitch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3NO, a control circuit voltage 230V AC, a power circuit voltage 1000V and a rated operational current 150 A.
Functional-unit Unitunit
Energy Model - Manufacturing [A1-a3]Electricity Mix; Production mix; Low voltage; CN
Energy Model - Use [B6]Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential In %54
Width Nominal120 mm
[Ith] Conventional Free Air Thermal Current200 A (at 60 °C) for power circuit
[Ue] Rated Operational Voltagepower circuit <= 1000 V AC 25...400 Hzpower circuit <= 300 V DC
Nbr. Of Units In Pkg.1
Take-backNo
Acidification (Ap) (Mole Of H+ Equiv) Benefits/Loads Beyond System Boundaries [D]-1.0159
Climate Change - Biogenics ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D]-1.0864
Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6]81.145
Climate Change - Fossil Fuels ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D]-33.289
Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6]81.355
Climate Change - Total ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D]-34.376
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4]8.635
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6]15622
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Benefits/Loads Beyond System Boundaries [D]-686.16
Ecotoxicity (Fresh Water) (Ctue) Distribution [A4]2.9164
Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6]574.56
Ecotoxicity (Fresh Water) (Ctue) Benefits/Loads Beyond System Boundaries [D]-770.61
Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4]2.3664
Impacts Related To Land Use/Soil Quality (-) Manufacturing [A1-a3]-14.274
Impacts Related To Land Use/Soil Quality (-) End Of Life [C1-c4]5.5746
Ionizing Radiation Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6]2108.8
Materials For Recycling (Kg) End Of Life [C1-c4]1.1987
Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3]9.8388
Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6]7.8228
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle25.501
Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle17673.7096
Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4]8.6351
Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6]17067
Total Use Of Primary Energy During The Life Cycle (Mj) Benefits/Loads Beyond System Boundaries [D]-713.07
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6]1444.3
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Benefits/Loads Beyond System Boundaries [D]-26.913
Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]25.501
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4]8.635
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6]15622
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D]-686.16
Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]2.7395
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]12.546
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4]1.4624
Water Use (M3 Eq) Manufacturing [A1-a3]5.0366
Water Use (M3 Eq) End Of Life [C1-c4]3.0383
Customs Code8536490065

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Take Back
No
Mercury Free
Yes
Circularity Profile
ENVEOLI100405EN
Eu Rohs Directive
Compliant By Exemption
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Verification Date
2025-11-10
Psr Version
PSR-0005-ed2-2016 03 29
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Recycled Metal Content At Cr Level0 %
Carbon Footprint107.56103
Environmental DisclosureENVPEP0603001EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
Pep CodeENVPEP0603001EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$1054.02/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!