TeSys Deca Contactor 3P 150A 415V AC Coil IP20
TeSys Deca Contactor 3P 150A 415V AC Coil IP20
Schneider Electric

Schneider Electric LC1D150N7 TeSys Deca Contactor 3P 150A 415V AC Coil IP20

  • MPN: LC1D150N7
  • PPN: SCH-LC1D150N7

CAD

$1317.52

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys Deca Contactor 3P 150A 415V AC Coil IP20

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Czechia
Depth136 mm

Complementary Attributes

Control Circuit Voltage Limits
0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz, 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz
Maximum Horse Power Rating
40 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Maximum Operating Rate
1200 cyc/h at 60 °C
Minimum Switching Voltage
17 V for signalling circuit
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947
Control Circuit TypeAC 50/60 Hz
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity1400 A at 440 V for power circuit conforming to IEC 60947

Important Information Attributes

Persona Type Ids
EU, OM, OM8, PB
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 315 A gG at <= 690 V coordination type 1 for power circuit, 250 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability
0.85 Mcycles 150 A AC-3 <= 440 V, 1 Mcycles 200 A AC-1 <= 440 V, 0.85 Mcycles 150 A AC-3e <= 440 V
Insulation Resistance
> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw
75 kW at 380/400 V AC 50/60 Hz (AC-3e), 80 kW at 415/440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 100 kW at 660/690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e)40 kW at 220/230 V AC 50/60 Hz (AC-3), 75 kW at 380/400 V AC 50/60 Hz (AC-3), 80 kW at 415/440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 100 kW at 660/690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 40 kW at 220/230 V AC 50/60 Hz (AC-3e), 22 kW at 400 V AC 50/60 Hz (AC-4)
Operating Time
20...35 ms closing, 40...75 ms opening
Safety Reliability Level
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation Category
AC-3, AC-3e, AC-1, AC-4
[Icw] Rated Short-time Withstand Current
250 A 40 °C - 10 min for power circuit, 580 A 40 °C - 1 min for power circuit, 1200 A 40 °C - 10 s for power circuit, 1400 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
[Ue] Rated Operational Voltage
power circuit <= 1000 V AC 25...400 Hz, power circuit <= 300 V DC
Connections - Terminals
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end
Non-overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]
4.425806016866926, 4 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
22 kg CO2 eq., 22.22881266064238
Local Data Status
Publishable
Return Indicator
N
Stock Policy
2
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI100405EN
Reach Full Compliance Status Id
CONTAINS_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
1904
China Rohs In Scope
No
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Coil Technology
built-in bidirectional peak limiting diode suppressor
Contact Compatibility
M13
Fire Resistance
850 °C IEC 60695-2-1
Heat Dissipation
3-4.5 W at 50/60 Hz
Number Of Poles
3P
Pole Contact Composition
3 NO
Product Or Component Type
contactor
Range
TeSys
Returnability
No
Software Version
v5.9.4
Total Lifecycle Carbon Footprint
113 kg CO2 eq.
Control Circuit Voltage 18 Control Circuit Voltage
415 V
Database Version
2022-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3NO, a control circuit voltage 230V AC, a power circuit voltage 1000V and a rated operational current 150 A.
Functional-unit Unit
unit
Energy Consumption On Product Lifetime, In Kwh
1281.15
Energy Model - Installation [A5]
Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]
Electricity Mix; Production mix; Low voltage; FR
Height Nominal
158 mm
[Ith] Conventional Free Air Thermal Current
200 A (at 60 °C) for power circuit
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947
Package Weight(Lbs)
2.470 kg
Warranty (In Months)
18
Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
Market SegmentationCommercial, Industrial
Contactor Applicationresistive load, motor control
Inrush Power In Va280-350 VA 60 Hz cos phi 0.9 (at 20 °C), 280-350 VA 50 Hz cos phi 0.9 (at 20 °C)
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor closed 15 Gn for 11 ms), shocks contactor open 6 Gn for 11 ms)
Mounting Supportplate, rail
Power Dissipation Per Pole24 W AC-1, 13.5 W AC-3, 13.5 W AC-3e
Tightening Torquecontrol circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Certificate AgencyUL, CCC, CSA, CE, UKCA, Marine, EAC
[Ie] Rated Operational Current200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V UL, power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
Hold-in Power Consumption In Va2-18 VA 60 Hz cos phi 0.9 (at 20 °C), 2-18 VA 50 Hz cos phi 0.9 (at 20 °C)
Carbon Footprint Of The Distribution Phase [A4]0.7508929239734572, 0.8 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0.3 kg CO2 eq., 0.2654427709841767
Carbon Footprint Of The Use Phase [B2, B3, B4, B6]86 kg CO2 eq., 85.59833633093525
Local Publishable Date2025-02-26
Stocking FlagY
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
Compatibility CodeLC1D
Device Short NameLC1D
Flame RetardanceV1 conforming to UL 94
Mechanical Durability8 Mcycles
Overvoltage CategoryIII
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
Range Of ProductTeSys Deca
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep CodeENVPEP0603001EN
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime, In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Production mix; Low voltage; CN
Energy Model - Use [B6]Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential, In %54
Width Nominal120 mm
[Uc] Control Circuit Voltage415 V AC 50/60 Hz
Nbr. Of Units In Pkg.1
Take-backNo

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Take Back
No
Mercury Free
Yes
Circularity Profile
ENVEOLI100405EN
Environmental Disclosure
ENVPEP0603001EN
Ip Degree Of Protection
IP20 front face IEC 60529
Packaging Made With Recycled Cardboard
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C, 60-70 °C with derating
Recycled Metal Content At Cr Level0 %
Carbon Footprint113.26929070340219
Climatic WithstandIACS E10 exposure to damp heat
Eu Rohs DirectiveCompliant By Exemption
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Pep CodeENVPEP0603001EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$1317.52/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])