Key Specifications
- Country of Origin
- Brazil, Czechia, France, United States
Complementary Attributes
- Control Circuit Voltage Limits
- 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz, 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz
- Maximum Horse Power Rating
- 40 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Maximum Operating Rate
- 1200 cyc/h at 60 °C
- Minimum Switching Voltage
- 17 V for signalling circuit
Important Information Attributes
- Persona Type Ids
- EU, OM, OM8, PB
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Associated Fuse Rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1, 315 A gG at <= 690 V coordination type 1 for power circuit, 250 A gG at <= 690 V coordination type 2 for power circuit
- Electrical Durability
- 0.85 Mcycles 150 A AC-3 <= 440 V, 1 Mcycles 200 A AC-1 <= 440 V, 0.85 Mcycles 150 A AC-3e <= 440 V
- Insulation Resistance
- > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Motor Power Kw
- 75 kW at 380/400 V AC 50/60 Hz (AC-3e), 80 kW at 415/440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 100 kW at 660/690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e)40 kW at 220/230 V AC 50/60 Hz (AC-3), 75 kW at 380/400 V AC 50/60 Hz (AC-3), 80 kW at 415/440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 100 kW at 660/690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 40 kW at 220/230 V AC 50/60 Hz (AC-3e), 22 kW at 400 V AC 50/60 Hz (AC-4)
- Operating Time
- 20...35 ms closing, 40...75 ms opening
- Safety Reliability Level
- B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
- Utilisation Category
- AC-3, AC-3e, AC-1, AC-4
- [Icw] Rated Short-time Withstand Current
- 250 A 40 °C - 10 min for power circuit, 580 A 40 °C - 1 min for power circuit, 1200 A 40 °C - 10 s for power circuit, 1400 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
- [Ue] Rated Operational Voltage
- power circuit <= 1000 V AC 25...400 Hz, power circuit <= 300 V DC
- Connections - Terminals
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end
- Non-overlap Time
- 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
- Carbon Footprint Of The End-of-life Phase [C1 To C4]
- 4.425806016866926, 4 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase [A1 To A3]
- 22 kg CO2 eq., 22.22881266064238
- Local Data Status
- Publishable
- Return Indicator
- Y
- Stock Policy
- 2
- Serviceability
- No
- Field Service Division
- PPIBS
- Weee Scope
- In
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI100405EN
- Reach Full Compliance Status Id
- CONTAINS_SVHC
- Rohs Eur In Scope
- Yes
- Rohs Eur Conformity Date
- 1904
- China Rohs In Scope
- No
- Without Single Use Plastic
- Yes
- Tier Id
- 1
- Function Option Id
- STANDARD
- Product Kit Identifier
- N
- Coil Technology
- built-in bidirectional peak limiting diode suppressor
- Contact Compatibility
- M13
- Fire Resistance
- 850 °C IEC 60695-2-1
- Heat Dissipation
- 3-4.5 W at 50/60 Hz
- Number Of Poles
- 3P
- Pole Contact Composition
- 3 NO
- Product Or Component Type
- contactor
- Range
- TeSys
- Returnability
- Yes
- Software Version
- v5.9.4
- Total Lifecycle Carbon Footprint
- 113 kg CO2 eq.
- Control Circuit Voltage 18 Control Circuit Voltage
- 48 V
- Database Version
- 2022-01
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
- Functional-unit Description
- Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3NO, a control circuit voltage 230V AC, a power circuit voltage 1000V and a rated operational current 150 A.
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime, In Kwh
- 1281.15
- Energy Model - Installation [A5]
- Electricity Mix; Production mix; Low voltage; FR
- Energy Model - End Of Life [C1-c4]
- Electricity Mix; Production mix; Low voltage; FR
- Height Nominal
- 158 mm
- [Ith] Conventional Free Air Thermal Current
- 200 A (at 60 °C) for power circuit
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV IEC 60947
- Package Weight(Lbs)
- 2.531 kg
- Warranty (In Months)
- 18
Environment Attributes Main
- China Rohs Regulation
- Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
- Take Back
- No
- Mercury Free
- Yes
- Circularity Profile
- ENVEOLI100405EN
- Environmental Disclosure
- ENVPEP0603001EN
- Ip Degree Of Protection
- IP20 front face IEC 60529
- Packaging Made With Recycled Cardboard
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Pep Verification Date
- 2025-08-05
- Psr Version
- PSR-0005-ed2-2016 03 29
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$1317.52
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$1317.52/ EA
Loading add to cart quantity...