Weidmuller

Weidmuller 1469540000 PRO ECO3 240W 24V 10A

  • MPN: 1469540000
  • PPN: WDM-1469540000

CAD

$448.09

/ EA

Available to Order from Manufacturer

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

Power supply, switch-mode power supply unit, 24 V

Documentation & Downloads

Specifications

General Data

AC failure bridging time @ I> 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC
Earth leakage current, max.3.5 mA
IndicationGreen LED (Uoutput > 21.6 V DC), Yellow LED (loutput > 90 % IRated typ. ), red LED (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Max. perm. air humidity (operational)5 %…95 % RH
Operating temperature-25 °C...70 °C
Power loss, idling8 W
Protection against over-heatingYes
Protection degreeIP20
Degree of efficiency88%
Housing versionMetal, corrosion resistant
MTBF> 500,000 h in accordance with IEC 61709 (SN29500)
Mounting position, installation noticeon terminal rail TS 35
Power factor (approx.)> 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC
Power loss, nominal load26 W
Protection against reverse voltages from the load30…35 V DC
Short-circuit protectionYes

Signalling

Contact load (NO contact)max. 30 V DC / 1 A
Relay on/offOutput voltage >21.6 V DC/ <20.4 V DC, overload
Floating contactYes

Connection Data (Input)

Conductor cross-section, AWG/kcmil , max.12
Conductor cross-section, flexible , min.0.5 mm²
Conductor cross-section, rigid , min.0.5 mm²
Number of terminals4 for L1/L2/L3/PE
Tightening torque, min.0.5 Nm
Conductor cross-section, AWG/kcmil , min.26
Conductor cross-section, rigid , max.6 mm²
Connection systemScrew connection
Tightening torque, max.0.6 Nm
Wire connection cross section, flexible (input), max.2.5 mm²

Approvals

ApprovalsCE, CULUS, cURus, EAC, TUEV
UL File Number SearchE258476
ROHSConform

Dimensions And Weights

Width60 mm
Height125 mm
Depth100 mm
Net weight962 g
Width (inches)2.362 inch
Height (inches)4.921 inch
Depth (inches)3.937 inch

Electrical Safety (Applied Standards)

Electrical machine equipmentAcc. to EN60204
Protection against dangerous shock currentsAcc. to VDE0106-101
Safety extra-low voltageSELV according to EN 60950, PELV according to EN 60204
For use with electronic equipmentAcc. to EN50178 / VDE0160
Protective separation / protection against electrical shockVDE0100-410 / acc. to DIN57100-410
Safety transformers for switch-mode power suppliesAccording to EN 61558-2-16

Rated Data Ul

Certificate No. (cURus)E255651

Emc / Shock / Vibration

Limiting of mains voltage harmonic currentsAccording to EN 61000-3-2
Vibration resistance IEC 60068-2-61 g according to EN 50178
Shock resistance IEC 60068-2-2715 g In all directions
Noise emission in accordance with EN55032Class B
Interference immunity test acc. toEN 61000-4-2 (ESD), EN 61000-4-3 (RS), EN 61000-4-4 (burst), EN 61000-4-5 (surge), EN 61000-4-6 (conducted), EN61000-4-8 (Fields), EN61000-4-11 (Dips)

Input

AC current consumption0.6 A @ 3 x 500 V AC / 0.8 A @ 3 x 400 V AC
Connection systemScrew connection
DC input voltage range450...800 V DC (max. 500 V DC acc. to UL508)
Input frequency47...63 Hz
Inrush currentmax. 50 A
Recommended back-up fuse2 A / DI, safety fuse2...3 A, Char. C, circuit breaker
AC input voltage range3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
DC current consumption0.4 A @ 800 V DC / 0.7 A @ 450 V DC
Frequency range AC47...63 Hz
Input fuse (internal)Yes
Rated input voltage3 x 400...3 x 500 V AC (wide-range input)
Surge protectionVaristor

Classifications

ETIM 6.0EC002540
eClass 9.027-04-07-01
eClass 10.027-04-07-01
ETIM 7.0EC002540
eClass 9.127-04-07-01

Output

Capacitive loadunrestricted
Continous output current @ U10 A @ 55 °C, 2.5 A @ 70 °C
Output power240 W
Overload protectionYes
Protection against inverse voltageYes
Rated output voltage24 V DC ± 1 %
Connection systemScrew connection
Nominal output current for U10 A @ 55 °C
Output voltage22...28 V (adjustable via potentiometer)
Parallel connection optionyes, max. 5
Ramp-up time≤ 100 ms
Residual ripple, breaking spikes< 50 mVPP @ 24 V DC, IN

Environmental Product Compliance

REACH SVHCLead 7439-92-1

Insulation Coordination

Insulation voltage input / earth2 kV
Insulation voltage, input/output3 kV
Protection classI, with PE connection
Insulation voltage output / earth0.5 kV
Pollution severity2

Connection Data (Output)

Conductor cross-section, AWG/kcmil , max.12
Conductor cross-section, flexible , max.2.5 mm²
Conductor cross-section, rigid , max.6 mm²
Connection systemScrew connection
Tightening torque, max.0.6 Nm
Conductor cross-section, AWG/kcmil , min.26
Conductor cross-section, flexible , min.0.5 mm²
Conductor cross-section, rigid , min.0.5 mm²
Number of terminals6 (++,--,13,14)
Tightening torque, min.0.5 Nm

Temperatures

Operating temperature, max.70 °C
Storage temperature, max.85 °C
Operating temperature-25 °C...70 °C
Operating temperature, min.-25 °C
Storage temperature, min.-40 °C
Storage temperature-40 °C...85 °C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)E258476
PRO ECO3 240W 24V 10A
PRO ECO3 240W 24V 10A
PRO ECO3 240W 24V 10A
PRO ECO3 240W 24V 10A
PRO ECO3 240W 24V 10A
CAD$448.09/EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!