TeSys Ultra Control Unit 3-12A, 690V AC, IP20, Class 10 Protection
Schneider Electric

Schneider Electric LUCA12FU TeSys Ultra Control Unit 3-12A, 690V AC, IP20, Class 10 Protection

  • MPN: LUCA12FU
  • PPN: SCH-LUCA12FU

CAD

$227.22

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys U standard control unit to be inserted in power bases LUB12, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 5.5kW@400V. It provides full protection to motors with a rated current Ir 3-12A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine).

Features

  • Featuring a versatile current setting range of 3 to 12 Amps, this LUCA standard control unit allows for fine-tuned thermal protection tailored to your specific motor s nameplate. This precision prevents motor burnout caused by subtle overloads while avoiding the productivity-killing nuisance trips common with fixed-rating protection devices.
  • Designed with a wide-range "FU" coil compatible with both AC and DC voltages from 110V to 240V, this unit offers maximum flexibility for industrial automation upgrades. This broad compatibility simplifies your inventory by replacing multiple voltage-specific parts and ensures seamless integration with standard PLC outputs or manual push-button stations.
  • As a core component of the TeSys Ultra (U) innovative motor starter system, this unit snaps directly onto a power base without the need for complex control wiring. This modular architecture allows industrial maintenance teams to perform rapid hot-swaps and system reconfigurations, slashing MTTR (Mean Time To Repair) and keeping your production line moving.
  • Beyond standard thermal protection, this unit provides critical "Class 10" tripping performance, including sensitivity to phase failure and phase imbalance. By instantly detecting a lost phase or unbalanced load, the LUCA12FU prevents catastrophic motor winding damage and expensive downtime in critical pumping, conveyor, or fan applications.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
France, United States
Depth60 mm

Complementary Attributes

Control Circuit Voltage Limits
55 V DC 110...220 V drop-out, 88...264 V AC 110...240 V in operation, 88...242 V DC 110...220 V in operation55 V AC 110...240 V drop-out

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Device Application
motor control, motor protection
Function Available
protection against overload and short-circuit, manual reset, earth fault protection, protection against phase failure and phase imbalance
Motor Power Kw
5.5 kW 400...440 V AC 50/60 Hz, 5.5 kW 500 V AC 50/60 Hz9 kW 690 V AC 50/60 Hz
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Thermal Overload Class
class 10 40-60 Hz -25-70 °C IEC 60947-6-2, class 10 40-60 Hz -25-70 °C UL 508
Utilisation Category
AC-41, AC-43, AC-44
[Ui] Rated Insulation Voltage
690 V IEC 60947-6-2600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Carbon Footprint Of The End-of-life Phase [C1 To C4]
0.31296898800484324, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
1 kg CO2 eq., 1.1947135351162859
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
1
Serviceability
No
Field Service Division
PPIBS
Weee Applicability
Finished product
Weee Product Category
5
Eoli Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant By Exemption
Rohs Eur Full Compliance Status
Compliant By Exemption
China Rohs Label
7
Without Single Use Plastic
Yes
Tier Id
2
Function Option Id
STANDARD
Product Kit Identifier
N
Device Short Name
LUCA
Fixing Mode
plug-in (front face)
Immunity To Radioelectric Fields
10 V IEC 61000-4-6
Load Type
3-phase motor self-cooled
Phase Failure Sensitivity
yes
Product Name
TeSys Ultra
Product Specific Application
basic protection requirements for motor starters: overload and short-circuit
Range
TeSys
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-28 kV 4 on contact IEC 61000-4-2
Returnability
Yes
Software Version
v6.1
Thermal Protection Adjustment Range
3-12 A
Tripping Threshold
14.2 x Ir +/- 20 %
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
R Thermal Protection Adj Range
3-12 A
Control Circuit Voltage 3 Control Circuit Type
DC
Pep Code
ENVPEP2406038EN
Pep Verification Date
2024-06-01
Psr Version
PSR-0005-ed3.1-EN-2023 12 08
Data Source
referent product
Functional-unit Quantity
1
Reference Lifetime In Y
20
Energy Model - Manufacturing [A1-a3]
France, FR
Energy Model - Use [B6]
Electricity Mix; Low voltage; 2018; France, FR
Recyclability Potential In %
56
Width Nominal
45 mm
[Ue] Rated Operational Voltage
690 V AC
Non-dissipating Shock Wave
1 kV serial mode IEC 60947-6-22 kV common mode IEC 60947-6-2
Nbr. Of Units In Pkg.
1
Take-back
No
Customs Code
8536308000
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
Market SegmentationCommercial, Industrial
Fire Resistance960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
Heat Dissipation2-2 W control circuit with LUB123-3 W control circuit with LUB32, 3-3 W control circuit with LUB38
Operating Time50 ms closing with LUB32 control circuit50 ms closing with LUB38 control circuit, 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit50 ms closing with LUB12 control circuit
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Typical Current Consumption280 mA 110...220 V DC I maximum while closing with LUB32, 280 mA 110...220 V DC I maximum while closing with LUB38, 25 mA 110...240 V AC I rms sealed with LUB38, 35 mA 110...220 V DC I rms sealed with LUB12, 25 mA 110...220 V DC I rms sealed with LUB32, 25 mA 110...220 V DC I rms sealed with LUB38, 280 mA 110...240 V AC I maximum while closing with LUB12, 280 mA 110...240 V AC I maximum while closing with LUB32, 280 mA 110...240 V AC I maximum while closing with LUB38280 mA 110...220 V DC I maximum while closing with LUB1235 mA 110...240 V AC I rms sealed with LUB12, 25 mA 110...240 V AC I rms sealed with LUB32
Certificate AgencyCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Carbon Footprint Of The Distribution Phase [A4]0.06838356635823767, 0.1 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0 kg CO2 eq., 0.009708208612935209
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]15 kg CO2 eq., 14.924864966718356
Local Publishable Date2026-06-27
Stocking FlagY
Device TypeRelay, Control & Measurement - measuring, monitoring device
TraceabilityYes
Average Life Duration15 year(s)
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI2406038EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1927
China Rohs In ScopeYes
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier2
Function OptionStandard
Compatibility CodeLUCA
Energy Efficiency OptimizedFalse
Immunity To Microbreaks3 ms
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Network Frequency40...60 Hz
Product AvailabilityStock - Normally stocked in distribution facility
Product Or Component Typestandard control unit
Protective TreatmentTH IEC 60068
Range Of ProductTeSys Ultra
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Shock Resistance10 gn power poles open IEC 60068-2-2715 gn power poles closed IEC 60068-2-27
Sustainable PackagingYes
Total Lifecycle Carbon Footprint17 kg CO2 eq.
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-64 gn 5-300 Hz power poles closed IEC 60068-2-6
Pop DirectiveNo POPs
Control Circuit Voltage 3 Control Circuit Voltage110...220 V
Load Type 6 Load Type3-phase motor
Database Version2023-02
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent external review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh223.38
Energy Model - Installation [A5]Electricity Mix; Low voltage; 2018; France, FR
Energy Model - End Of Life [C1-c4]Electricity Mix; Low voltage; 2018; France, FR
Height Nominal66 mm
[Uc] Control Circuit Voltage110...240 V AC110...220 V DC
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Halogen-free StatusHalogen free plastic parts product
Package Weight(Lbs)128.000 g
Warranty (In Months)18

Environment Attributes Main

Ambient Air Temperature For Storage
-40-85 °C, -40-85 °C
Product Compatibility
power base LUB12, power base LUB32, power base LUB38, power base LUB120, power base LUB320, power base LUB380reversing contactor breaker LU2B12FU, reversing contactor breaker LU2B32FU, reversing contactor breaker LU2B38FU
Halogene Performance
Halogen free plastic parts product
China Rohs Regulation
X
Carbon Footprint
16.51063926481066
Circularity Profile
ENVEOLI2406038EN
Eu Rohs Directive
Compliant By Exemption
Operating Altitude
6561.68 ft (2000 m)
Packaging Without Single Use Plastic
Yes
Pep Code
ENVPEP2406038EN
Pcr Version
PCR-4-ed4-EN-2021 09 06
Type Of Verification For The Pep
Independent external review
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1IP40 front panel outside connection zone IEC 60947-1
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Temperature For Operation-25-70 °C-25-70 °C
Environmental DisclosureENVPEP2406038EN
Halogen Content PerformanceHalogen free plastic parts product
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2024-06-01
Psr VersionPSR-0005-ed3.1-EN-2023 12 08

General Attributes

Product Or Component Type
standard control unit
Range Of ProductTeSys Ultra

ETIM

ETIM 8
EC000617
ETIM 9EC000617

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months