Features
- Featuring a highly precise current adjustment dial ranging from 0.35A to 1.4A, this advanced control unit is custom-engineered for 3-phase fractional horsepower motors up to 0.25 kW at 400V. This wide adjustment range allows industrial technicians to fine-tune thermal settings exactly to the motor s specific nameplate FLA (Full Load Amps), preventing nuisance trips while safeguarding low-current machinery from overheating.
- Designed as an direct plug-and-play component, this control unit seamlessly slides into the front face of standard TeSys Ultra modular power bases, including the LUB120, LUB320, and LUB380 series. The front-mount clip design eliminates the need for complex rewiring or backpanel drilling, allowing automated system builders to complete swap-outs or system retrofits in seconds.
- Engineered to operate on a 24V DC control circuit voltage (with functional operation guaranteed between 20V to 27V DC), this module integrates smoothly with modern industrial PLC outputs and standardized low-voltage DC power supplies. Utilizing standard low-voltage DC control increases control cabinet safety while mitigating electrical noise and inductive feedback on system communication networks.
- This multi-functional control unit features built-in diagnostics that defend against earth faults, phase failure, phase imbalance, short circuits (tripping at 13 x Irmax), and overcurrent. By instantly tripping the circuit breaker before electrical faults propagate, it ensures total equipment protection and isolates localized issues to reduce plant-wide downtime.
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Brazil, France, United States
Complementary Attributes
- Control Circuit Voltage Limits
- 20...27 V DC 24 V in operation14.5 V DC 24 V drop-out
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Device Application
- motor control, motor protection
- Function Available
- earth fault protection, protection against phase failure and phase imbalance, protection against overload and short-circuit, manual reset
- Operating Time
- 70 ms closing with LUB32 control circuit70 ms closing with LUB38 control circuit, 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit70 ms closing with LUB12 control circuit
- Safe Separation Of Circuit
- 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Typical Current Consumption
- 80 mA 24 V DC I rms sealed with LUB38, 130 mA 24 V DC I maximum while closing with LUB12220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB3860 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32
- Certificate Agency
- CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
- Carbon Footprint Of The Distribution Phase [A4]
- 0.0635753468486741, 0.1 kg CO2 eq.
- Carbon Footprint Of The Installation Phase [A5]
- 0 kg CO2 eq., 0.009025600194838203
- Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
- 18 kg CO2 eq., 17.704986872283545
- Local Publishable Date
- 2026-06-27
- Stocking Flag
- N
- Device Type
- Relay, Control & Measurement - measuring, monitoring device
- Traceability
- Yes
- Average Life Duration
- 15 year(s)
- Weee Scope
- In
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI2406038EN
- Reach Full Compliance Status Id
- CONTAINS_SVHC
- Rohs Eur In Scope
- Yes
- Rohs Eur Conformity Date
- 2423
- China Rohs In Scope
- Yes
- With Recycled Cardboard
- Yes
- Product Contributes To Saved And Avoided Emissions
- No
- Tier
- 2
- Function Option
- Standard
- Compatibility Code
- LUCB
- Energy Efficiency Optimized
- False
- Immunity To Microbreaks
- 3 ms
- Immunity To Voltage Dips
- 70 % / 500 ms IEC 61000-4-11
- Motor Power Kw
- 0.25 kW 400...440 V AC 50/60 Hz
- Phase Failure Sensitivity
- yes
- Product Name
- TeSys Ultra
- Product Specific Application
- basic protection and advanced functions, communication
- Range
- TeSys
- Reset
- manual reset
- Resistance To Radiated Fields
- 10 V/m 3 IEC 61000-4-3
- Shock Resistance
- 10 gn power poles open IEC 60068-2-2715 gn power poles closed IEC 60068-2-27
- Sustainable Packaging
- Yes
- Total Lifecycle Carbon Footprint
- 19 kg CO2 eq.
- Vibration Resistance
- 2 gn 5-300 Hz power poles open IEC 60068-2-64 gn 5-300 Hz power poles closed IEC 60068-2-6
- R Thermal Protection Adj Range
- 0.35-1.4 A
- Pep Code
- ENVPEP2406038EN
- Pep Verification Date
- 2024-06-01
- Psr Version
- PSR-0005-ed3.1-EN-2023 12 08
- Data Source
- extrapolated product
- Functional-unit Quantity
- 1
- Reference Lifetime In Y
- 20
- Energy Model - Manufacturing [A1-a3]
- France, FR
- Energy Model - Use [B6]
- Electricity Mix; Low voltage; 2018; France, FR
- Recyclability Potential In %
- 56
- Width Nominal
- 45 mm
- [Ue] Rated Operational Voltage
- 690 V AC
- Halogen-free Status
- Halogen free plastic parts product
- Package Weight(Lbs)
- 119.0 g
- Warranty (In Months)
- 18
Environment Attributes Main
- Ambient Air Temperature For Storage
- -40-85 °C, -40-85 °C
- Product Compatibility
- power base LUB12, power base LUB32, power base LUB38, power base LUB120, power base LUB320, power base LUB380reversing contactor breaker LU2B12BL, reversing contactor breaker LU2B32BL, reversing contactor breaker LU2B38BL
- Halogene Performance
- Halogen free plastic parts product
- China Rohs Regulation
- X
- Carbon Footprint
- 19.179261415041232
- Circularity Profile
- ENVEOLI2406038EN
- Eu Rohs Directive
- Compliant By Exemption
- Operating Altitude
- 6561.68 ft (2000 m)
- Packaging Without Single Use Plastic
- Yes
- Pep Code
- ENVPEP2406038EN
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
General Attributes
- Product Or Component Type
- advanced control unit
ETIM
- ETIM 8
- EC000617
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$284.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$284.98/ EA
Loading add to cart quantity...