Schneider Electric ATV650U75N4EU Altivar Process Variable Speed Drive, 7.5kW, 400…480V, IP55


Schneider Electric ATV650U75N4EU Altivar Process Variable Speed Drive, 7.5kW, 400…480V, IP55
- MPN: ATV650U75N4EU
- PPN: SCH-ATV650U75N4EU
- UNSPSC: 39122001
Spec sheet
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
CAD$3042.20/ EA
Description
Altivar Process Variable Speed Drive, 7.5kW, 400…480V, IP55
Specifications
Conformance Attributes
- Standards
- environment 1 category C2 environment 2 category C3 IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, IEC 61800-3
Complementary Attributes
- Maximum Horse Power Rating
- 7.5 hp heavy duty, 10 hp normal duty
- Maximum THDI
- <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
- UE Rated Operational Voltage
- 380...480 V 7.5 kW 10 hp normal duty, 380...480 V 5.5 kW 7.5 hp heavy duty
- Maximum Associated Fuse Rating
- 25.0 A
- Maximum Output Voltage
- 480.0 V
- US Rated Supply Voltage
- 380...480 V - 15...10 %
- Maximum Acceleration Under Shock Load During Storage
- 150 m/s² at 11 ms
- Maximum Acceleration Under Vibrational Stress During Operation
- 10 m/s² at 13...200 Hz
- Maximum Acceleration Under Vibratory Load During Transport
- 10 m/s² at 13...200 Hz
- Maximum Deflection Under Vibratory Load During Storage
- 1.5 mm at 2...13 Hz
Maximum Switching Currentrelay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Maximum Transient Current19.1 A 60 s heavy duty), 18.2 A 60 s normal duty)
Brake Chopper Integratedfalse
Maximum Input Current Per Phase13.8 A
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Maximum Acceleration Under Shock Impact During Operation150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation1.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport1.5 mm at 2...13 Hz
Important Information Attributes
- Persona Type Ids
- EU, OM, OM8, SI
- Apparent Power
- 7.6 kVA 480 V heavy duty), 9.9 kVA 480 V normal duty)
- Connector Type
- RJ45 on the remote graphic terminal)Modbus serial, RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
- Electromagnetic Compatibility
- radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
- Frequency Resolution
- analog input 0.012/50 Hz, display unit 0.1 Hz
- Line Current
- 11.9 A 480 V normal duty), 10.5 A 380 V heavy duty), 9.2 A 480 V heavy duty), 13.8 A 380 V normal duty)
- Local Signalling
- 3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage, 3 LEDs for local diagnostic
- Motor Slip Compensation
- adjustable, can be suppressed, not available in permanent magnet motor law, automatic whatever the load
- Permissible Temporary Current Boost
- 1.5 x In 60 s heavy duty), 1.1 x In 60 s normal duty)
- Sampling Duration
- 5 ms +/- 1 ms DI5, DI6) - discrete input, 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input, 10 ms +/- 1 ms AO1) - analog output, 2 ms +/- 0.5 ms DI1...DI4) - discrete input
- Switching Frequency
- 4...12 kHz with derating factor, 2...12 kHz adjustable
- Vibration Resistance
- 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
- Environmental Class During Transport
- class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
- Carbon Footprint Of The End Of Life Phase C1 To C4
- 3.4514551845, 3 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase A1 To A3
- 213 kg CO2 eq., 213.022056239
- Local Data Status
- Publishable
- Device Type
- Variable speed drive - VSD Compacts
- Traceability
- Yes
- Average Life Duration
- 10 year(s)
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI1508009EN
- Reach Full Compliance Status Id
- CONTAINS_SVHC
- ROHS EUR In Scope
- No
- ROHS EUR Full Compliance Status
- Pro-active compliance (Product out of EU RoHS legal scope)
- China ROHS In Scope
- Yes
- With Recycled Cardboard
- Yes
- Product Contributes To Saved And Avoided Emissions
- No
- WD Status
- 5 - INITIALIZED WITH DataSCAN OK (Migration)
- Function Option Id
- ADVANCED
- Market Segmentation Id
- INDUSTRIAL
- 1 Phase Low Current Possible
- false
- Application In Domestic And Commercial Area Permitted
- false
- Base Load Current At Low Overload
- 16.5 A
- Capacity Of Dc Link
- 1000.0 µF
- Design Of Frequency Changer
- U converter
- Enclosure Mounting
- wall mounted
- Housing Material
- plastic
- Maximum Associated Fuse Rating
- 25.0 A
- Method Of Access
- slave Modbus TCP
- Nominal Switching Frequency
- 4 kHz
- Operating Element Present
- true
- Package Weight Lbs
- 23.0 kg
- Power Loss Static Current Independent
- 17.0 W
- Product Or Component Type
- variable speed drive
- Range Of Product
- Altivar Process ATV600
- Relative Symmetric Mains Voltage Tolerance
- 10 %
- Returnability
- Yes
- Shock Resistance
- 15 gn 11 ms IEC 60068-2-27
- Supporting Protocol For As Interface Safety At Work
- false
- Supporting Protocol For Bacnet
- false
- Supporting Protocol For Data Highway
- false
- Supporting Protocol For Devicenet Safety
- false
- Supporting Protocol For Foundation Fieldbus
- false
- Supporting Protocol For Knx
- false
- Supporting Protocol For Modbus
- true
- Supporting Protocol For Profibus
- true
- Supporting Protocol For Profinet Io
- true
- Supporting Protocol For Safetybus P
- false
- Supporting Protocol For Suconet
- false
- Sustainable Packaging
- No
- Variant
- with disconnect switch
- With Safety Function Safe Programmable Logic
- false
- Permitted Relative Humidity During Transport
- class 2K5 according to EN 60721-3
- With Safety Function Safe Direction SDI
- false
- With Safety Function Safe Position Sp
- false
- With Safety Function Safe Stop 1 SS1
- false
- With Safety Function Safely Limited Position Slp
- false
- With Sft Fct Safe Stop 2 Ss2
- false
- Application In Industrial Area Permitted
- true
- Pep Code
- ENVPEP1508009EN
- PCR Version
- PCR-ed3-EN-2015 04 02
- Functional Unit Description
- To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 5,5 kW electric motors for fluid management and industrial applications in IP55 conditions, at 380V to 480V rated 3-phase voltage supply. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
- Product Kit Identifier
- N
Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
Asynchronous Motor Control Profileconstant torque standard, optimized torque mode, variable torque standard
Electrical Connectionmotor screw terminal 6...10 mm², line side screw terminal 4...6 mm², control removable screw terminals 0.5...1.5 mm²
EMC Filterintegrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Insulation Resistance> 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
Linearity ErrorAO1, AO2 +/- 0.2 % analog output, AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Motor Power KW5.5 kW heavy duty), 7.5 kW normal duty)
Option Cardslot A communication module, PROFINET, slot A communication module, DeviceNet, slot A communication module, Modbus TCP/EtherNet/IP, slot A communication module, CANopen daisy chain RJ45, slot A communication module, CANopen SUB-D 9, slot A communication module, CANopen screw terminals, slot A/slot B digital and analog I/O extension module, slot A/slot B output relay extension module, slot A communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink, slot A communication module, Profibus DP V1
Protection Typesafe torque off motor, motor phase break motor, thermal protection drive, safe torque off drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, motor phase break drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive, thermal protection motor
Supplyinternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection, external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
Synchronous Motor Control Profilesynchronous reluctance motor, permanent magnet motor
Environmental Class During Storageclass 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
Carbon Footprint Of The Distribution Phase A43.3777091388, 3 kg CO2 eq.
Carbon Footprint Of The Installation Phase A58 kg CO2 eq., 8.4315922671
Carbon Footprint Of The Use Phase B2 B3 B4 B67 916 kg CO2 eq., 7916.4894184123
Local Publishable Date2026-01-12
ServiceabilityNo
Field Service DivisionIDIBS
Legacy WEEE ScopeIn
EOLI Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
ROHS EUR StatusCompliant with Exemptions
ROHS EUR Full Compliance Status IdPRO_ACTIVE_COMPLIANCE
Green Premium Status For ReportingGreen Premium product
Without Single Use PlasticNo
Return IndicatorY
Dangerous Goods CodeLITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
Function OptionAdvanced
Market SegmentationIndustrial
4 Quadrant Operation Possiblefalse
Base Load Current At High Overload12.7 A
Braking To Standstillby DC injection
Computer Porttrue
Device Short NameATV650
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Isolationbetween power and control terminals
Maximum Input Current Per Phase13.8 A
Noise Level52 dB 86/188/EEC
Number Of Addresses1-247 Modbus serial
Optical Interface Presentfalse
Power Loss Per Device Current Dependent259.0 W
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Product Specific Applicationprocess and utilities
Refresh Timerelay output R1, R2, R3)5 ms +/- 0.5 ms)
Relative Symmetric Network Frequency Tolerance5 %
Safety FunctionSTO (safe torque off) SIL 3
Supply Frequency50...60 Hz - 5...5 %
Supporting Protocol For Asifalse
Supporting Protocol For Cantrue
Supporting Protocol For Devicenetfalse
Supporting Protocol For Ethernet Iptrue
Supporting Protocol For Interbusfalse
Supporting Protocol For Lonfalse
Supporting Protocol For Other Bus Systemsfalse
Supporting Protocol For Profinet Cbatrue
Supporting Protocol For Profisafefalse
Supporting Protocol For Sercosfalse
Supporting Protocol For TCP IPtrue
Total Lifecycle Carbon Footprint8 145 kg CO2 eq.
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
EMC Limit Value Compliedtrue
With Safety Function Safe Brake Management Sbc Sbtfalse
With Safety Function Safe Operating Stop Sosfalse
With Safety Function Safe Speed Monitor Ssmfalse
With Safety Function Safe Torque Off Stotrue
With Safety Function Safely Limited Speed Slsfalse
Relationship Typecross-selling relationship
Supporting Protocol For Interbus Safetyfalse
Pep Verification Date2021-11-01
Type Of Verification For The PepIndependent external review
Functional Unit Unitunit
Product ManagerLEONARDO LAZZARO
Environment Attributes Main
- Ambient Air Temperature For Operation
- 40-50 °C (with derating factor), -15-40 °C (without derating), -15-40 °C (without derating)
- IP Degree Of Protection
- IP55IEC 60529, IP55IEC 61800-5-1
- Environmental Class During Operation
- class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
- Take Back
- No
- China ROHS Regulation
- X
- Carbon Footprint
- 8144.7722312419
- Circularity Profile
- ENVEOLI1508009EN
- Packaging Made With Recycled Cardboard
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Permitted Relative Humidity During Operation
- class 3K5 according to EN 60721-3
- Pep Code
- ENVPEP1508009EN
- PCR Version
- PCR-ed3-EN-2015 04 02
EU ROHS DirectiveCompliant By Exemption, Pro-active compliance (Product out of EU RoHS legal scope)
Operating Altitude1000...4800 m with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
ROHS Exemption InformationYes
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Transport Temperature-40-70 °C
Environmental DisclosureENVPEP1508009EN
Packaging Without Single Use PlasticNo
Relative Humidity5-95 % without condensation IEC 60068-2-3
Permitted Relative Humidity During Storageclass 1K5 according to EN 60721-3
Pep Verification Date2021-11-01
Type Of Verification For The PepIndependent external review
General Attributes
- Product Or Component Type
- variable speed drive
Range Of ProductAltivar Process ATV600
Output Attributes
- Analogue Output Type
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
- Discrete Output Type
- relay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mA
- Maximum Output Voltage
- 480.0 V
- Speed Drive Output Frequency
- 0.1-500 Hz
Continuous Output Current12.7 A 4 kHz heavy duty, 16.5 A 4 kHz normal duty
Relay Output Typeconfigurable relay logic R2 sequence relay NO 100000 cycles, configurable relay logic R3 sequence relay NO 100000 cycles, configurable relay logic R1 fault relay NO/NC 100000 cycles
Relay Output Number3
Surge Protection And Filtering Attributes
- EMC Filter
- integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Input Attributes
- Analogue Input Type
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
- Input Compatibility
- DI5, DI6 discrete input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2, DI1...DI6 discrete input level 1 PLC IEC 61131-2
- Number Of Input Phases
- 3
Discrete Input Logicpositive logic (source) DI1...DI8), < 5 V, > 11 V, negative logic (sink) DI1...DI8), > 16 V, < 10 V
Discrete Input TypeDI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Batteries & Runtime Attributes
- Removable Battery
- YES
Downloads
Video
Similar Products
CAD$3042.20/ EA
Loading add to cart quantity...