Schneider Electric ATV650D18N4EU Altivar Process VFD Variable Speed Drive 18.5kW 400-480V IP55
Schneider Electric
ATV650D18N4EU
Altivar Process VFD Variable Speed Drive 18.5kW 400-480V IP55
MPN: ATV650D18N4EU
PPN: SCH-ATV650D18N4EU
Spec sheet
Loading compare button...
If you can't find the product or are unsure which one you need, please use the Product Selector tool below
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Description
Altivar Process VFD Variable Speed Drive 18.5kW 400-480V IP55
Specifications
Communications & Management Attributes
Communication Port Protocol
Ethernet, Modbus TCP
Complementary Attributes
Maximum Horse Power Rating
20 hp heavy duty, 25 hp normal duty
Maximum Thdi
<48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
Ue Rated Operational Voltage
380...480 V 18.5 kW 25 hp normal duty, 380...480 V 15 kW 20 hp heavy duty
Brake Chopper Integrated
false
Maximum Input Current Per Phase
33.4 A
Maximum Output Voltage
480.0 V
Maximum Acceleration Under Shock Impact During Operation
150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport
150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage
10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation
1.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport
1.5 mm at 2...13 Hz
Maximum Switching Currentrelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Maximum Transient Current47.6 A 60 s heavy duty), 43.1 A 60 s normal duty)
Us Rated Supply Voltage380...480 V, 380...480 V - 15...10 %
Maximum Associated Fuse Rating63.0 A
Maximum Output Frequency500 kHz
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Maximum Acceleration Under Shock Load During Storage150 m/s² at 11 ms
Maximum Acceleration Under Vibrational Stress During Operation10 m/s² at 13...200 Hz
Maximum Acceleration Under Vibratory Load During Transport10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Storage1.5 mm at 2...13 Hz
Important Information Attributes
Product Contributes To Saved And Avoided Emissions
YES_SSI2, Yes
Persona Type Names
End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
Asynchronous Motor Control Profile
constant torque standard, optimized torque mode, variable torque standard
Electrical Connection
line side screw terminal 10...16 mm², motor screw terminal 10...16 mm², control removable screw terminals 0.5...1.5 mm²
Emc Filter
integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Insulation Resistance
> 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
Linearity Error
AO1, AO2 +/- 0.2 % analog output, AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Motor Power Kw
15 kW heavy duty), 18.5 kW normal duty)
Noise Level
53.7 dB 86/188/EEC, 53.7 dB
Permissible Temporary Current Boost
1.5 x In 60 s heavy duty), 1.1 x In 60 s normal duty)
Protection Type
safe torque off drive, motor phase break drive, thermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
Supply
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection, external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
Synchronous Motor Control Profile
synchronous reluctance motor, permanent magnet motor
Vibration Resistance
1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
Environmental Class During Transport
class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
Carbon Footprint Of The End Of Life Phase C1 To C4
5.6326465927, 6 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A3
223 kg CO2 eq., 222.6584786054
Certificate Agency
CSA, DNV-GL, TÜV, ATEX INERIS, ATEX zone 2/22
Local Publishable Date
2026-01-12
Stocking Flag
Y
Device Type
Variable speed drive - VSD Compacts
Traceability
Yes
Average Life Duration
10 year(s)
Weee Product Category
4
Eoli Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant By Exemption
Rohs Eur Full Compliance Status
Compliant By Exemption
China Rohs Label
5
Without Single Use Plastic
No
Tier Id
2
Function Option Id
ADVANCED
Market Segmentation Id
INDUSTRIAL
Product Kit Identifier
N
4 Quadrant Operation Possible
false
Base Load Current At High Overload
31.7 A
Braking To Standstill
by DC injection
Computer Port
true
Design Of Frequency Changer
U converter
Enclosure Mounting
wall mounted
Housing Material
plastic
Marking
CE
Maximum Input Current Per Phase
33.4 A
Mounting Mode
wall mount
Nominal Switching Frequency
4 kHz
Number Of Hw Interfaces Industrial Ethernet
1
Number Of Output Phases
3
Operating Position
vertical +/- 10 degree
Overvoltage Category
III
Power Loss Per Device Current Dependent
616.0 W
Product Availability
Stock - Normally stocked in distribution facility
Product Specific Application
process and utilities
Quantity Per Set
1
Refresh Time
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Relative Symmetric Mains Voltage Tolerance
10 %
Returnability
Yes
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Supply Frequency
50...60 Hz - 5...5 %
Supporting Protocol For Asi
false
Supporting Protocol For Can
true
Supporting Protocol For Devicenet
false
Supporting Protocol For Ethernet Ip
true
Supporting Protocol For Interbus
false
Supporting Protocol For Lon
false
Supporting Protocol For Other Bus Systems
false
Supporting Protocol For Profinet Cba
true
Supporting Protocol For Profisafe
false
Supporting Protocol For Sercos
false
Supporting Protocol For Tcp Ip
true
Total Lifecycle Carbon Footprint
18 351 kg CO2 eq.
Type Of Cooling
forced convection
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Application In Industrial Area Permitted
true
Emc Limit Value Complied
true
With Safety Function Safe Brake Management Sbc Sbt
false
With Safety Function Safe Operating Stop Sos
false
With Safety Function Safe Speed Monitor Ssm
false
With Safety Function Safe Torque Off Sto
true
With Safety Function Safely Limited Speed Sls
false
Warranty In Months
18
Database Version
2016-11
Pcr Version
PCR-ed3-EN-2015 04 02
Data Source
extrapolated product
Functional Unit Quantity
1
Reference Lifetime In Y2
10
Energy Model Manufacturing A1 A3 2
Energy model used: China
Energy Model Use B6 2
Electricity Mix; AC; < 1kV; EU-27
Offer Owner Code
190786
Height Nominal
678 mm
Persona Type IdsEU, OM, OM8, SI
Apparent Power20.3 kVA 480 V heavy duty), 24 kVA 480 V normal duty)
Connector TypeRJ45 on the remote graphic terminal)Modbus serial, RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Electromagnetic Compatibilityradiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Frequency Resolutionanalog input 0.012/50 Hz, display unit 0.1 Hz
Line Current28.9 A 480 V normal duty), 27.7 A 380 V heavy duty), 24.4 A 480 V heavy duty), 33.4 A 380 V normal duty)
Local Signalling3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage, 3 LEDs for local diagnostic
Motor Slip Compensationadjustable, can be suppressed, not available in permanent magnet motor law, automatic whatever the load
Option Cardslot A communication module, PROFINET, slot A communication module, DeviceNet, slot A communication module, Modbus TCP/EtherNet/IP, slot A communication module, CANopen daisy chain RJ45, slot A communication module, CANopen SUB-D 9, slot A communication module, CANopen screw terminals, slot A/slot B digital and analog I/O extension module, slot A/slot B output relay extension module, slot A communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink, slot A communication module, Profibus DP V1
Sampling Duration5 ms +/- 1 ms DI5, DI6) - discrete input, 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input, 10 ms +/- 1 ms AO1) - analog output, 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Switching Frequency4...12 kHz with derating factor, 2...12 kHz adjustable
Environmental Class During Storageclass 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
Carbon Footprint Of The Distribution Phase A44.109318542, 4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A57 kg CO2 eq., 7.4109270998
Carbon Footprint Of The Use Phase B2 B3 B4 B618 111 kg CO2 eq., 18111.4681307913
Local Data StatusPublishable
Return IndicatorY
Stock Policy1
ServiceabilityYes
Field Service DivisionIDIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1406001EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeNo
Rohs Eur Conformity Date1921
China Rohs In ScopeYes
With Recycled CardboardYes
Dangerous Goods CodeLITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
Tier2
Function OptionAdvanced
Market SegmentationIndustrial
1 Phase Low Current Possiblefalse
Application In Domestic And Commercial Area Permittedfalse
Base Load Current At Low Overload39.2 A
Capacity Of Dc Link1500.0 µF
Data Format8 bits, configurable odd, even or no parity
Device Short NameATV650
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Isolationbetween power and control terminals
Maximum Associated Fuse Rating63.0 A
Method Of Accessslave Modbus TCP
Network Frequency50-60 Hz
Number Of Addresses1-247 Modbus serial
Number Of Hw Interfaces Serial Rs4851
Operating Element Presenttrue
Optical Interface Presentfalse
Phase3 phase
Power Loss Static Current Independent23.0 W
Product Or Component Typevariable speed drive
Prospective Line Isc50 kA
Range Of ProductAltivar Process ATV600
Regulation Loopadjustable PID regulator
Relative Symmetric Network Frequency Tolerance5 %
Safety FunctionSTO (safe torque off) SIL 3
Software VersionEIME v5.9.1
Supporting Protocol For As Interface Safety At Workfalse
Supporting Protocol For Bacnetfalse
Supporting Protocol For Data Highwayfalse
Supporting Protocol For Devicenet Safetyfalse
Supporting Protocol For Foundation Fieldbusfalse
Supporting Protocol For Knxfalse
Supporting Protocol For Modbustrue
Supporting Protocol For Profibustrue
Supporting Protocol For Profinet Iotrue
Supporting Protocol For Safetybus Pfalse
Supporting Protocol For Suconetfalse
Sustainable PackagingNo
Transmission FrameRTU
Type Of Polarizationno impedance
With Safety Function Safe Programmable Logicfalse
Supporting Protocol For Interbus Safetyfalse
Permitted Relative Humidity During Transportclass 2K5 according to EN 60721-3
With Safety Function Safe Direction Sdifalse
With Safety Function Safe Position Spfalse
With Safety Function Safe Stop 1 Ss1false
With Safety Function Safely Limited Position Slpfalse
With Sft Fct Safe Stop 2 Ssfalse
Pep CodeENVPEP1406001EN
Pep Verification Date2021-11-01
Type Of Verification For The PepIndependent external review
Functional Unit DescriptionTo adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 22 kW electric motors for fluid management and industrial applications in IP55/UL type 1 conditions, at 380V to 480V rated 3-phase voltage supply, with disconnect switch. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
Functional Unit UnitUnit
Energy Consumption On Product Lifetime In Kwh30675.943
Energy Model Installation A5 2Electricity Mix; AC; < 1kV; EU-27
Energy Model End Of Life C1 C4 2Electricity Mix; AC; < 1kV; EU-27
Pn1
Width Nominal264 mm
Environment Attributes Main
Ambient Air Temperature For Operation
-15-40 °C (without derating), -15-40 °C (without derating), -15-50 °C, 40-50 °C (with derating factor), -15-40 °C (without derating), -15-40 °C (without derating)
Ip Degree Of Protection
IP55, IP55IEC 60529, IP55IEC 61800-5-1
Environmental Class During Operation
class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Ambient Air Temperature For Storage
-40-70 °C
Environmental Disclosure
ENVPEP1406001EN
Nema Degree Of Protection
NEMA 12
Packaging Without Single Use Plastic
No
Relative Humidity
5-95 % without condensation IEC 60068-2-3
Permitted Relative Humidity During Storage
class 1K5 according to EN 60721-3
Pep Verification Date
2021-11-01
Type Of Verification For The Pep
Independent external review
Ambient Air Transport Temperature-40-70 °C, -40-70 °C
Operating Altitude<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 1000...4800 m with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
Take BackNo
China Rohs RegulationX
Carbon Footprint18351.2795016313
Circularity ProfileENVEOLI1406001EN
Eu Rohs DirectiveCompliant By Exemption
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Permitted Relative Humidity During Operationclass 3K5 according to EN 60721-3
Pep CodeENVPEP1406001EN
Pcr VersionPCR-ed3-EN-2015 04 02
General Attributes
Phase
3 phase
Range Of Product
Altivar Process ATV600
Product Or Component Typevariable speed drive
ETIM
ETIM 8
EC001857
ETIM 9EC001857
Output Attributes
Analogue Output Type
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
Discrete Output Type
relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mA, relay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA
Analogue Output Number
2
Maximum Output Frequency
500 kHz
Nominal Output Current
39.2 A
Output Voltage
<= power supply voltage
Speed Drive Output Frequency
0.1-500 Hz
Continuous Output Current31.7 A 4 kHz heavy duty, 39.2 A 4 kHz normal duty
integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Input Attributes
Analogue Input Type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits