Fluke i30s AC/DC Current Clamp
Fluke

Fluke I30S Fluke i30s AC/DC Current Clamp

  • MPN: I30S
  • UPC: 095969345101
  • PPN: FLU-I30S

CAD

$1128.72

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

Fluke i30s AC/DC Current Clamp is used in conjunction with oscilloscopes for accurate non-intrusive current measurement. Contact us for more information.

Specifications

Electrical specifications

Usable current range
5 mA to 30 A DC, 30 mA to 20 A AC rms
Conductor position sensitivity
±1% relative to center reading
Working voltage (see Safety Standards section)
300 V AC rms or DC
Specified current range
30 mA to 30 A DC, 30 mA to 20 A AC rms
Frequency range
DC to 100 kHz (-0.5 dB)
Accuracy (at +25°C)
±1% of reading ±2 mA
Crest factor
1.4 in
Output sensitivity100 mV/A
Resolution±1 mA
Temperature coefficient±0.01% of reading / °C
Power supply9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Load impedance> 100 kΩ
Phase shift below 1 kHz< 2°

General Specifications

Operating humidity
15% to 85% (non-condensing)
EMC standards
EN 61326: 1998 +A1, A2, and A3
Maximum conductor size
19 mm diameter
Operating temperature range
0°C to +50°C
Safety standards
BS EN 61010-1: 2001
Output connection
Safety BNC connector, supplied with safety 4 mm adapter
Storage temperature range (with battery removed)
-20°C to +85°C
Cable length2 m
Safety standardsBS EN 61010-2-032: 2002
Output zeroManual adjust via thumbwheel
Safety standardsBS EN 61010-031: 2002
Safety standardsUse of the probe on uninsulated conductors is limited to 300 V AC rms or DC and frequencies below 1 kHz
Weight250 g
Safety standards300 Vrms, Category III, Pollution Degree 2