Discontinued Product. Occupancy Sensor with Photocell , Provolt™ Lighting Control 2 Pole, Line Voltage, 8'-12' Ceiling Mounted, Ultrasonic, 2000 sq ft, Daylighting, Auto-Calibration, 120-277V AC/CA 50/60HZ. UL/CE, RoHS & CEC Title 20/24 compliant. Color: White

Features

  • Utilizes sensors which emit non-audible sound waves and sense movement. Any movement within the sensor’s field-of-view causes a shift in the original emitted frequency. The sensor identifies the change as movement and controls light accordingly. U/S models are immune to external ultrasonic signals from other sources such as white-boards delivering uninterrupted performance.
  • Auto-Adapting: Time delay and sensitivity are continually adjusted to occupancy pattern of use
  • Vacancy Sensing Time Outs: (Delayed OFF Timer, Exclusive Walk-through Feature, Time delay and saved settings are protected during power outages and will return to the last known state)
  • Output short circuit protection
  • Industry-exclusive self-configuring local manual switch input: Momentary or maintained switches are supported
  • Presentation Mode allows user to turn lights OFF and keep them OFF while the room is occupied
  • Adjustable Time Delay: 30s, 5min, 10min, 20min, 30min
  • Test Mode for simplified commissioning
  • Manual Switch and Emergency Override are Class 1 or Class 2 circuits. Class 2 circuits provided for flexibility
  • Industry-exclusive “fail-safe” circuitry: In the event of product failure, Return-to-Closed feature causes the relay to default ON which eliminates life safety concerns
  • Industry-exclusive H.I.S. (High Inrush Stability) technology designed to handle today’s high inrush electronic ballast loads and offer unmatched durability and service
  • Robust and reliable mechanically held 10A latching relay provides dependability and robust performance for all load types and provides energy savings over electronically held relays
  • Field of View: Units from 500 to 2000 square feet available
  • Visual LED indicators for all states: (Green - Blinks during U/S detection and is solid during auto-calibration, Yellow - Blinks during test mode; solid with emergency/BMS input, Blue - Blinks when knob settings are changed and during photocell override
  • The Leviton Provolt ™ Dual Relay Occupancy Sensors combine line voltage occupancy sensors and photocells into a self-contained unit. The integrated design alleviates the need for separate power pack and occupancy sensor wiring making it a low-cost, efficient energy solution for new construction and retrofits. Do you have a question about an occupancy sensor or vacancy sensor?

Documentation & Downloads

Specifications

Key Specifications

Country of OriginChina
RoHS CompliantFalse

Standards and Certifications

ListingsCA Title 20/24 Compliant, UL 773A (Occupancy Standard), UL 924 (Emergency Equipment), cUL Listed, CE Compliant, NOM Certified, RoHS Compliant, NY LLC48 Compliant
Title 24 CompliantYes

Performance Specifications

Coverage (Sq.Ft.)2000

Mechanical Specifications

Mounting TypeCeiling Mount
SizeWidth 4.80" (121.92mm), Depth 2.27" (57.79mm)
Relay TypeDual Relay

Product Features

ApplicationDaylight Harvesting|Code Compliance|Auto ON/Auto OFF|Manual ON/Auto OFF|Fan Control|Auto ON/Manual ON|Stairwell Control|Step Dimming
FeatureUltrasonic Line Voltage Dual Relay
MountingCeiling Mount
Sensor TechnologyUltrasonic (US)
Time Delay30s-30m
ColorWhite
GradeCommercial
Product LineProvolt
Sensor TypeOccupancy, Photocell

Warranty

Warranty5-Year Limited

Environmental Specifications

Operating Temperature32° to 104°F (0° to 40°C)
Storage Temperature Range-15° to 160°F (-26° to 71°C)
Relative Humidity0% to 90% non-condensing

Electrical Specifications

Current Consumption60-30mA
Load Rating120V, 50/60Hz: 8A, Electronic Ballast, 800W, Tungsten, 800VA Ballast, 1/4 HP Motor - 230V, 50Hz: 6A/6AX, Electronic Ballast, Magnetic Ballast, Tungsten, 1/3 HP Motor - 277V, 50/60Hz: 5A, Electronic Ballast, 1200VA Ballast, 1/3 HP Motor
Voltage120/230/277 VAC
Frequency50/60Hz
Neutral Wire ConnectionRequired

Type

Product TypeOccupancy Sensor and Photocell
Ultrasonic Occupancy Sensor & Photocell, Ceiling Mount, 2000 Sq Ft, Dual Relay, 120-277V
Ultrasonic Occupancy Sensor & Photocell, Ceiling Mount, 2000 Sq Ft, Dual Relay, 120-277V
Ultrasonic Occupancy Sensor & Photocell, Ceiling Mount, 2000 Sq Ft, Dual Relay, 120-277V
Ultrasonic Occupancy Sensor & Photocell, Ceiling Mount, 2000 Sq Ft, Dual Relay, 120-277V
Ultrasonic Occupancy Sensor & Photocell, Ceiling Mount, 2000 Sq Ft, Dual Relay, 120-277V
Loading video…

Similar Products

Loading carousel layout...

CAD$398.87/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!