Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching
Schneider Electric

Schneider Electric SSP1A450M7 Harmony Solid State Relay 50A Panel Mount, 90-280V AC Input, Zero Voltage Switching

  • MPN: SSP1A450M7
  • PPN: SCH-SSP1A450M7
  • If you can't find the product or are unsure which one you need, please use the Product Selector tool below
  • CAD

    $91.11

    / EA

    Available to Order

    Lead times may vary. For an accurate estimate please contact us.

    Available To Ship Immediately:0

    Loading dialog...

    Looking to buy a large quantity?

    To View Branch Inventory And Your Custom Pricing

    Spec sheet

    Description

    This panel mount static relay accepts wiring with either bare cable, crimped cable ends, fork lugs or ring lugs Its rated current is 50 A, is controlled with a 90 to 280 V DC circuit, has a rated load voltage of 48 to 660 V DC output. It also has a test button for easy debugging, testing and commissioning It mounts on metallic panel surface, with an excellent thermal dissipation capability thanks to its factory-installed thermal pad, or on DIN rails with an accessory heatsink It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events

    Documentation & Downloads

    Specifications

    Key Specifications

    Country of Origin
    Brazil

    Complementary Attributes

    Maximum Voltage Drop
    <1.15 V on-state, <1.15 V on-state<1.15 V on-state, <1.15 V on-state
    Line Rated Current
    50 A
    Maximum Leakage Current
    1 mA off-state
    Minimum Switching Voltage
    90 V AC turn-on
    Absolute Maximum Voltage1200 V
    Maximum Horse Power Rating0.75 hp 120 V AC2 hp 240 V AC5 hp 480 V AC
    Maximum Switching Voltage10 V AC turn-off
    Rated Current50 A

    Important Information Attributes

    Persona Type Ids
    BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    Market Segmentation Id
    COMMERCIAL, INDUSTRIAL
    Control Type
    without test button, without test button
    Marking
    EAC, CE, UL, CSA
    Control Circuit Voltage
    90...280 V
    [Uc] Control Circuit Voltage
    AC, 90...280 V
    Connections - Terminals
    ring lugs 11.7 x 4.5 mm outputscrew terminals 0.2...3.3 mm², 24 AWG...12 AWG) with cable end input, screw terminals 0.5...5.26 mm², 20 AWG...10 AWG) with cable end output, screw terminals 0.2...3.3 mm², 24 AWG...12 AWG) without cable end inputscrew terminals 0.5...8.26 mm², 20 AWG...8 AWG) without cable end outputforked type tag connectors 9.2 x 4 mm input, ring lugs 9.2 x 4 mm input, forked type tag connectors 11.7 x 4.5 mm output, screw connectors
    Carbon Footprint Of The Distribution Phase [A4]
    0.0127730412, 0 kg CO2 eq.
    Carbon Footprint Of The Installation Phase [A5]
    0.0005551553, 0 kg CO2 eq.
    Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
    5 428 kg CO2 eq., 5427.8000067051
    Local Publishable Date
    2026-01-12
    Stocking Flag
    N
    Weee Scope
    Out
    Scope Perimeter
    At least in Europe
    End Of Life Doc Ref
    ENVEOLI1505006EN
    Reach Full Compliance Status Id
    CONTAINS_SVHC
    Rohs Eur In Scope
    No
    Rohs Eur Conformity Date
    1930
    China Rohs In Scope
    Yes
    With Recycled Cardboard
    Yes
    Product Contributes To Saved And Avoided Emissions
    No
    Tier
    1
    Function Option
    Standard
    Cos Phi
    0.5-0.5 (with maximum load)
    Insulation Resistance
    1000 MOhm at 500 V DC
    Local Signalling
    LED, green input
    Overvoltage Category
    III
    Product Availability
    Stock - Normally stocked in distribution facility
    Protection Device Type
    type 1 - 40 A miniature circuit breaker (MCB) Btype 2 - 32 A miniature circuit breaker (MCB) B
    Response Time
    30 ms (turn-off)25 ms (turn-on)
    Software Version
    EIME v5.8.1
    Thermal Resistance
    0.45 °C/W junction to case
    Total Lifecycle Carbon Footprint
    5 429 kg CO2 eq.
    Database Version
    2016-11
    Pcr Version
    PCR-ed3-EN-2015 04 02
    Type Of Verification For The Pep
    Independent internal review
    Functional-unit Description
    To switch ON/OFF electronic contact during 10 years at a 50% use rate.
    Functional-unit Unit
    unité (unit)
    Energy Consumption On Product Lifetime In Kwh
    9193.164
    Energy Model - Installation [A5]
    Electricity Mix; AC; &lt;lt/&gt; 1kV; EU-27
    Energy Model - End Of Life [C1-c4]
    Electricity Mix; AC; &lt;lt/&gt; 1kV; EU-27
    Dv/Dt
    500 V/µs off-state at maximum voltage
    Package Weight(Lbs)
    99.0 g
    Warranty (In Months)
    18
    Persona Type NamesCharge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    Market SegmentationCommercial, Industrial
    Dielectric Strength4 kV AC for input/output, 4 kV AC for input or output to case
    Safety Reliability DataB10d = 1731395, MTTFd = 1875.9 years
    Certificate AgencyEAC, CE, CSA, UL
    [Uimp] Rated Impulse Withstand Voltage6 kV output to case, 6 kV input to output
    Maximum I²T For Fusing1770 A².s for 10 ms at 50 Hz, 1629 A².s for 8.33 ms at 60 Hz
    Carbon Footprint Of The End-of-life Phase [C1 To C4]0 kg CO2 eq., 0.0234374845
    Carbon Footprint Of The Manufacturing Phase [A1 To A3]1 kg CO2 eq., 1.0987979381
    Local Data StatusPublishable
    Return IndicatorY
    Stock Policy2
    Weee Product Category5
    Eoli Availability DisplayYes
    Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
    Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
    Rohs Eur StatusCompliant By Exemption
    Rohs Eur Full Compliance StatusCompliant By Exemption
    China Rohs Label5
    Without Single Use PlasticYes
    Tier Id1
    Function Option IdSTANDARD
    Product Kit IdentifierN
    Device Short NameSSP1
    Load Current0.15-50 A
    Mounting Supportpanel
    Phase1 phase
    Product Or Component Typepanel mount relay
    Range Of ProductHarmony Solid State Relays
    ReturnabilityYes
    Sustainable PackagingYes
    Tightening Torque1.5...1.7 N.m for input2...2.2 N.m for output
    Pep CodeENVPEP1505006EN
    Pep Verification Date2019-05-01
    Psr VersionPSR-0005-ed2-EN-2016 03 29
    Data Sourceextrapolated product
    Functional-unit Quantity1
    Reference Lifetime In Y10
    Energy Model - Manufacturing [A1-a3]Energy model used: Mexico
    Energy Model - Use [B6]Electricity Mix; AC; &lt;lt/&gt; 1kV; EU-27
    Recyclability Potential In %56
    Nbr. Of Units In Pkg.1
    Take-backNo
    Customs Code8536490080

    Environment Attributes Main

    Ambient Air Temperature For Operation
    -40-80 °C, -40-80 °C
    Take Back
    No
    China Rohs Regulation
    X
    Carbon Footprint
    5428.9355703243
    Environmental Disclosure
    ENVPEP1505006EN
    Ip Degree Of Protection
    IP20
    Packaging Without Single Use Plastic
    Yes
    Pep Code
    ENVPEP1505006EN
    Pcr Version
    PCR-ed3-EN-2015 04 02
    Type Of Verification For The Pep
    Independent internal review
    Ambient Air Temperature For Storage-40-125 °C, -40-125 °C
    Recycled Metal Content At Cr Level0 %
    Mercury FreeYes
    Circularity ProfileENVEOLI1505006EN
    Eu Rohs DirectiveCompliant By Exemption
    Packaging Made With Recycled CardboardYes
    Reach RegulationReference contains Substances of Very High Concern above the threshold
    Pep Verification Date2019-05-01
    Psr VersionPSR-0005-ed2-EN-2016 03 29

    General Attributes

    Phase
    1 phase
    Range Of Product
    Harmony Solid State Relays
    Product Or Component Typepanel mount relay

    ETIM

    ETIM 8
    EC002055
    ETIM 9EC002055

    Output Attributes

    Solid State Output Type
    SCR output, zero voltage switching
    Output Voltage
    48...660 V AC
    Output Switching Modezero voltage switching

    Surge Protection And Filtering Attributes

    Surge Current
    625 A 16.6 ms

    Input Attributes

    Cos Phi
    0.5-0.5 (with maximum load)
    Input Current Limits5-10 mA

    Overview Attributes

    Device Presentation
    complete product
    Loading video…

    Accessories

    Loading carousel layout...

    Similar Products

    Loading carousel layout...

    CAD$91.11/ EA

    Loading add to cart quantity...

    banner

    Need assistance?

    We can help! Connect with our Sales Team Today!