Schneider Electric LC1D50ASD TeSys Deca Contactor 3P 50A 72V DC Coil, IP20 Protection
- MPN: LC1D50ASD
- PPN: SCH-LC1D50ASD
- UNSPSC: 39121529
CAD
$533.46
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Description
Features
- New modern look & feel of all machines
- Designed to meet the requirements of industrial and HVAC applications
- Easier to install and operate with multi-standard screws
- With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries
- Digital customer experience for technical documents
- Maintenance guide via EcoStruxureTM Facility Expect
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, France |
|---|---|
| Depth | 120 mm |
| Weight | 930 g |
|---|
Complementary Attributes
| Maximum Horse Power Rating | 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors3 hp at 115 V AC 50/60 Hz for 1 phase motors7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
|---|---|
| Ui Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1 |
| Control Circuit Voltage Limits | 0.1...0.3 Uc (-40-70 °C):drop-out DC0.75...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC |
| Maximum Motor Phase Current | 50 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
| Uc Control Circuit Voltage | 72 V72 V DC |
| Uimp Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Ie Rated Operational Current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
|---|---|
| Control Circuit Type | DC standard |
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1900 A at 440 V for power circuit conforming to IEC 60947 |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Icw Rated Short Time Withstand Current | 400 A 40 °C - 10 s for power circuit810 A 40 °C - 1 s for power circuit84 A 40 °C - 10 min for power circuit208 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| Ue Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit |
| Electrical Durability | 1.45 Mcycles 50 A AC-3 <= 440 V, 0.5 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 50 A AC-3e <= 440 V |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms) |
| Mounting Support | plate, rail |
| Range | TeSys, TeSys Deca |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| Control Circuit Voltage | 72 V |
| Non Overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 1.30645609471181, 1 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 5 kg CO2 eq., 4.598086506743781 |
| Local Data Status | Publishable |
| Return Indicator | N |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1503009EN |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 1926 |
| China Rohs In Scope | No |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Inrush Power In W | 19-19 W 20 °C) |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Non-Stock - Not normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Returnability | No |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Total Lifecycle Carbon Footprint | 87 kg CO2 eq. |
| Inf Motor Phase Current | 50 A |
| Data Source | extrapolated product |
| Width Nominal | 55 mm |
| Customs Code | 8536490065 |
| Hold In Power Consumption In W | 7.4-7.4 W 20 °C |
| Functional Unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional Unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 891.33 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Contactor Application | resistive load, motor control |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 22 kW at 380/400 V AC 50/60 Hz (AC-3e), 25 kW at 415 V AC 50/60 Hz (AC-3e), 30 kW at 440 V AC 50/60 Hz (AC-3e), 30 kW at 500 V AC 50/60 Hz (AC-3e), 33 kW at 660/690 V AC 50/60 Hz (AC-3e), 15 kW at 220/230 V AC 50/60 Hz (AC-3)22 kW at 380/400 V AC 50/60 Hz (AC-3)25 kW at 415 V AC 50/60 Hz (AC-3)30 kW at 440 V AC 50/60 Hz (AC-3), 30 kW at 500 V AC 50/60 Hz (AC-3)33 kW at 660/690 V AC 50/60 Hz (AC-3), 15 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 3.7 W AC-39.6 W AC-1, 3.7 W AC-3e |
| Tightening Torque | control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm, control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2, power circuit 2.5 N.m EverLink BTR screw connectors pozidriv No 2 |
| Connections Terminals | control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: 2 1-25 mm² - cable stiffness: solid without cable endEverLink BTR screw connectorscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable endpower circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible without cable end, EverLink BTR screw connectors |
| Certificate Agency | CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC |
| Carbon Footprint Of The Distribution Phase A4 | 0.43105045489028165, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 | 0.1 kg CO2 eq., 0.05614798644146796 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 80 kg CO2 eq., 80.1695225555932 |
| Local Publishable Date | 2026-06-27 |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Coil Technology | built-in bidirectional peak limiting diode suppressor |
| Contact Compatibility | M4 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Mechanical Durability | 10 Mcycles |
| Operating Time | 50 ±15 % ms closing16...24 ms opening |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.2.4 |
| Time Constant | 34 ms |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Database Version | 2024-01 |
| Height Nominal | 122 mm |
| Nbr. Of Units In Pkg. | 1 |
| Ith Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit |
| Warranty In Months | 18 |
| Functional Unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Recyclability Potential In % | 62 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope) |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1503009EN |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Free Of Svhc | Yes |
| Pep Code | ENVPEP1503009EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Reach Free Shvc | Yes |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 86.56126359838053 |
| Environmental Disclosure | ENVPEP1503009EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|---|
| ETIM 10 | EC000066 |
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty | 18 months |
|---|

Accessories
Loading carousel layout...
Loading carousel layout...
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$533.46
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
CAD$533.46/ EA
Loading add to cart quantity...