Schneider Electric ATV650D15N4U Altivar Process Variable Speed Drive, 15kW, 400-480V, IP55


Schneider Electric ATV650D15N4U Altivar Process Variable Speed Drive, 15kW, 400-480V, IP55
- MPN: ATV650D15N4U
- PPN: SCH-ATV650D15N4U
- UNSPSC: 39122001
Spec sheet
Loading compare button...
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
CAD$4245.68/ EA
Description
Designed for robust performance in demanding environments, the Altivar Process ATV600 variable speed drive from Schneider Electric is engineered to optimize control of asynchronous and synchronous motors. With a power rating of 15 kW and a voltage range of 400 to 480V, this drive ensures precise motor control while accommodating a variety of applications in process and utilities. Its IP55 rating signifies a high level of protection against dust and water, making it suitable for industrial settings.
The ATV600 features advanced safety functions, including Safe Torque Off (STO), ensuring operational safety while maintaining efficiency. With a maximum output frequency of 500 Hz and adjustable acceleration and deceleration ramps, it allows for smooth transitions and precise speed control. Furthermore, its integrated communication capabilities via Modbus TCP and Ethernet enhance connectivity, making it an ideal choice for modern automation systems. The drive also complies with multiple industry standards, ensuring reliability and performance in various applications.
Specifications
Communications & Management Attributes
- Communication Port Protocol
- Modbus serial, Ethernet
Conformance Attributes
- Product Certifications
- Bureau Veritas, UL, ATEX INERIS, CSA, ABS, DNV-GL
StandardsIEC 61800-3 environment 1 category C2, EN/IEC 61800-3 environment 2 category C3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, environment 1 category C2 IEC 61800-3, environment 2 category C3 IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, UL 508C
Complementary Attributes
- Maximum Horse Power Rating
- 15 hp heavy duty, 20 hp normal duty
- Maximum Thdi
- <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
- Brake Chopper Integrated
- false
- Maximum Input Current Per Phase
- 27.0 A
- Maximum Output Voltage
- 480.0 V
Maximum Switching Currentrelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC, relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC, relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Maximum Transient Current35.3 A 60 s heavy duty), 34.9 A 60 s normal duty)
Maximum Associated Fuse Rating50.0 A
Maximum Output Frequency500 kHz
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Important Information Attributes
- Product Contributes To Saved And Avoided Emissions
- YES_SSI2, Yes
- Persona Type Names
- End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
- Asynchronous Motor Control Profile
- constant torque standard, optimized torque mode, variable torque standard
- Electrical Connection
- line side screw terminal 10...16 mm², motor screw terminal 10...16 mm², control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
- EMC Filter
- integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
- Insulation Resistance
- > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
- Linearity Error
- AO1, AO2 +/- 0.2 % analog output, AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
- Motor Power KW
- 11 kW heavy duty), 15 kW normal duty)
- Noise Level
- 53.7 dB 86/188/EEC, 53.7 dB
- Permissible Temporary Current Boost
- 1.5 x In 60 s heavy duty), 1.1 x In 60 s normal duty)
- Protection Type
- safe torque off drive, motor phase break drive, thermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
- Supply
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection, external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
- Synchronous Motor Control Profile
- synchronous reluctance motor, permanent magnet motor
- Vibration Resistance
- 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
- Us Rated Supply Voltage2
- 380...480 V, 380...480 V - 15...10 %
- Environmental Class During Storage2
- class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
- Carbon Footprint Of The Distribution Phase A4
- 4.1028674925, 4 kg CO2 eq.
- Carbon Footprint Of The Installation Phase A5
- 7 kg CO2 eq., 7.3992929914
- Carbon Footprint Of The Use Phase B2 B3 B4 B6
- 14 801 kg CO2 eq., 14801.3780407012
- Environmental Class During Storage3
- class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
- Ue Rated Operational Voltage5
- 380...480 V 15 kW 20 hp normal duty, 380...480 V 11 kW 15 hp heavy duty
- Local Publishable Date
- 2026-01-12
- Serviceability
- Yes
- Field Service Division
- IDIBS
- Legacy WEEE Scope
- In
- EOLI Availability Display
- Yes
- Reach Full Compliance Status
- Reference contains Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Reference contains Substances of Very High Concern above the threshold
- ROHS EUR Status
- Compliant with Exemptions
- ROHS EUR Full Compliance Status Id
- PRO_ACTIVE_COMPLIANCE
- Green Premium Status For Reporting
- Green Premium product
- Without Single Use Plastic
- No
- Dangerous Goods Code
- LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
- Function Option
- Advanced
- Market Segmentation
- Industrial
- 4 Quadrant Operation Possible
- false
- Base Load Current At High Overload
- 23.5 A
- Braking To Standstill
- by DC injection
- Computer Port
- true
- Design Of Frequency Changer
- U converter
- Enclosure Mounting
- wall mounted
- Housing Material
- plastic
- Marking
- CE
- Maximum Input Current Per Phase
- 27.0 A
- Mounting Mode
- wall mount
- Nominal Switching Frequency
- 4 kHz
- Operating Element Present
- true
- Optical Interface Present
- false
- Package Weight Lbs
- 25.0 kg
- Power Loss Per Device Current Dependent
- 500.0 W
- Product Availability
- Non-Stock - Not normally stocked in distribution facility
- Product Specific Application
- process and utilities
- Range Of Product
- Altivar Process ATV600
- Regulation Loop
- adjustable PID regulator
- Relative Symmetric Network Frequency Tolerance
- 5 %
- Safety Function
- STO (safe torque off) SIL 3
- Supply Frequency
- 50...60 Hz - 5...5 %
- Supporting Protocol For Asi
- false
- Supporting Protocol For Can
- true
- Supporting Protocol For Devicenet
- false
- Supporting Protocol For Ethernet Ip
- true
- Supporting Protocol For Interbus
- false
- Supporting Protocol For Lon
- false
- Supporting Protocol For Other Bus Systems
- false
- Supporting Protocol For Profinet Cba
- true
- Supporting Protocol For Profisafe
- false
- Supporting Protocol For Sercos
- false
- Supporting Protocol For TCP IP
- true
- Total Lifecycle Carbon Footprint
- 15 041 kg CO2 eq.
- Type Of Cooling
- forced convection
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Emc Limit Value Complied2
- true
- Maximum Acceleration Under Shock Load During Storage2
- 150 m/s² at 11 ms
- Maximum Acceleration Under Vibrational Stress During Operation2
- 10 m/s² at 13...200 Hz
- Maximum Acceleration Under Vibratory Load During Transport2
- 10 m/s² at 13...200 Hz
- Maximum Deflection Under Vibratory Load During Storage2
- 1.5 mm at 2...13 Hz
- Permitted Relative Humidity During Operation2
- class 3K5 according to EN 60721-3
- Permitted Relative Humidity During Transport2
- class 2K5 according to EN 60721-3
- With Safety Function Safe Direction Sdi2
- false
- With Safety Function Safe Position Sp2
- false
- With Safety Function Safe Stop 1 SS1
- false
- With Safety Function Safely Limited Position Slp2
- false
- With Sft Fct Safe Stop 2 Ss
- false
- Supporting Protocol For Interbus Safety
- false
- Stocking Flag
- Y
- Emc Limit Value Complied3
- true
- Maximum Acceleration Under Shock Load During Storage3
- 150 m/s² at 11 ms
- Maximum Acceleration Under Vibrational Stress During Operation3
- 10 m/s² at 13...200 Hz
- Maximum Acceleration Under Vibratory Load During Transport3
- 10 m/s² at 13...200 Hz
- Maximum Deflection Under Vibratory Load During Storage3
- 1.5 mm at 2...13 Hz
- Permitted Relative Humidity During Operation3
- class 3K5 according to EN 60721-3
- Permitted Relative Humidity During Transport3
- class 2K5 according to EN 60721-3
- With Safety Function Safe Direction Sdi3
- false
- With Safety Function Safe Position Sp3
- false
- With Safety Function Safe Torque Off Sto3
- true
- With Safety Function Safely Limited Speed Sls3
- false
- Pep Code
- ENVPEP1406001EN
- Pep Verification Date
- 2021-11-01
- Type Of Verification For The Pep
- Independent external review
- Functional Unit Description
- To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 22 kW electric motors for fluid management and industrial applications in IP55/UL type 1 conditions, at 380V to 480V rated 3-phase voltage supply, with disconnect switch. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
- Energy Model Manufacturing A1 A3 2
- Energy model used: China
- Energy Model Use B6 2
- Electricity Mix; AC; < 1kV; EU-27
- Global Commercial Status
- Commercialised
- With Safety Function Safe Stop 1 Ss1 5
- false
Persona Type IdsEU, OM, OM8, SI
Apparent Power15 kVA 480 V heavy duty), 19.4 kVA 480 V normal duty)
Connector TypeRJ45 on the remote graphic terminal)Modbus serial, RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Electromagnetic Compatibilityradiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Frequency Resolutionanalog input 0.012/50 Hz, display unit 0.1 Hz
Line Current23.3 A 480 V normal duty), 20.6 A 380 V heavy duty), 18.1 A 480 V heavy duty), 27 A 380 V normal duty)
Local Signalling3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage, 3 LEDs for local diagnostic
Motor Slip Compensationadjustable, can be suppressed, not available in permanent magnet motor law, automatic whatever the load
Option Cardslot A communication module, PROFINET, slot A communication module, DeviceNet, slot A communication module, Modbus TCP/EtherNet/IP, slot A communication module, CANopen daisy chain RJ45, slot A communication module, CANopen SUB-D 9, slot A communication module, CANopen screw terminals, slot A/slot B digital and analog I/O extension module, slot A/slot B output relay extension module, slot A communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink, slot A communication module, Profibus DP V1
Product Destinationasynchronous motors, synchronous motors
Sampling Duration5 ms +/- 1 ms DI5, DI6) - discrete input, 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input, 10 ms +/- 1 ms AO1) - analog output, 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Switching Frequency4...12 kHz with derating factor, 2...12 kHz adjustable
Transmission Rate10, 100 Mbits, 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Ue Rated Operational Voltage2380...480 V 15 kW 20 hp normal duty, 380...480 V 11 kW 15 hp heavy duty
Environmental Class During Operation2class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
Environmental Class During Transport2class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
Carbon Footprint Of The End Of Life Phase C1 To C45.6238041334, 6 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A3222 kg CO2 eq., 222.3089362528
Environmental Class During Operation3class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
Environmental Class During Transport3class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
Local Data StatusPublishable
Device TypeVariable speed drive - VSD Compacts
TraceabilityYes
Average Life Duration10 year(s)
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1406001EN
Reach Full Compliance Status IdCONTAINS_SVHC
ROHS EUR In ScopeNo
ROHS EUR Full Compliance StatusPro-active compliance (Product out of EU RoHS legal scope)
China ROHS In ScopeYes
With Recycled CardboardYes
Return IndicatorY
Function Option IdADVANCED
Market Segmentation IdINDUSTRIAL
1 Phase Low Current Possiblefalse
Application In Domestic And Commercial Area Permittedfalse
Base Load Current At Low Overload31.7 A
Capacity Of Dc Link1500.0 µF
Data Format8 bits, configurable odd, even or no parity
Device Short NameATV650
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Isolationbetween power and control terminals
Maximum Associated Fuse Rating50.0 A
Method Of Accessslave Modbus TCP
Network Frequency50-60 Hz
Number Of Addresses1-247 Modbus serial
Operating Positionvertical +/- 10 degree
Overvoltage CategoryIII
Phase3 phase
Power Loss Static Current Independent23.0 W
Product Or Component Typevariable speed drive
Prospective Line Isc50 kA
Refresh Timerelay output R1, R2, R3)5 ms +/- 0.5 ms)
Relative Symmetric Mains Voltage Tolerance10 %
ReturnabilityYes
Shock Resistance15 gn 11 ms IEC 60068-2-27
Supporting Protocol For As Interface Safety At Workfalse
Supporting Protocol For Bacnetfalse
Supporting Protocol For Data Highwayfalse
Supporting Protocol For Devicenet Safetyfalse
Supporting Protocol For Foundation Fieldbusfalse
Supporting Protocol For Knxfalse
Supporting Protocol For Modbustrue
Supporting Protocol For Profibustrue
Supporting Protocol For Profinet Iotrue
Supporting Protocol For Safetybus Pfalse
Supporting Protocol For Suconetfalse
Sustainable PackagingNo
Transmission FrameRTU
Type Of Polarizationno impedance
With Safety Function Safe Programmable Logicfalse
Maximum Acceleration Under Shock Impact During Operation2150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport2150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage210 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation21.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport21.5 mm at 2...13 Hz
Permitted Relative Humidity During Storage2class 1K5 according to EN 60721-3
With Safety Function Safe Brake Management Sbc Sbt2false
With Safety Function Safe Operating Stop Sos2false
With Safety Function Safe Speed Monitor Ssm2false
With Safety Function Safe Torque Off Sto2true
With Safety Function Safely Limited Speed Sls2false
Application In Industrial Area Permittedtrue
Medium Descvariable speed drive, Altivar Process ATV600, ATV650, 15kW, 400...480V, IP55
Product Kit IdentifierN
Maximum Acceleration Under Shock Impact During Operation3150 m/s² at 11 ms
Maximum Acceleration Under Shock Load During Transport3150 m/s² at 11 ms
Maximum Acceleration Under Vibratory Load During Storage310 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load During Operation31.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load During Transport31.5 mm at 2...13 Hz
Permitted Relative Humidity During Storage3class 1K5 according to EN 60721-3
With Safety Function Safe Brake Management Sbc Sbt3false
With Safety Function Safe Operating Stop Sos3false
With Safety Function Safe Speed Monitor Ssm3false
With Safety Function Safely Limited Position Slp3false
With Sft Fct Safe Stop 2 Ss4false
Database Version2016-11
Pcr VersionPCR-ed3-EN-2015 04 02
Data Sourceextrapolated product
Functional Unit UnitUnit
Energy Model Installation A5 2Electricity Mix; AC; < 1kV; EU-27
Energy Model End Of Life C1 C4 2Electricity Mix; AC; < 1kV; EU-27
Us Rated Supply Voltage5380...480 V - 15...10 %
Environment Attributes Main
- Take Back
- Nej, No
- Ambient Air Transport Temperature
- -40-70 °C, -40-70 °C
- IP Degree Of Protection
- IP55, IP55IEC 60529, IP55IEC 61800-5-1
- ROHS Exemption Information
- Yes
- China ROHS Regulation
- X
- Carbon Footprint
- 15040.8129415712
- Circularity Profile
- ENVEOLI1406001EN
- Nema Degree Of Protection
- NEMA 12
- Packaging Without Single Use Plastic
- No
- Relative Humidity
- 5-95 % without condensation IEC 60068-2-3
- Pep Verification Date
- 2021-11-01
- Type Of Verification For The Pep
- Independent external review
Ambient Air Temperature For Operation-15-40 °C (without derating), -15-40 °C (without derating), -15-50 °C, 40-50 °C (with derating factor), -15-40 °C (without derating), -15-40 °C (without derating)
EU ROHS DirectiveCompliant By Exemption , Pro-active compliance (Product out of EU RoHS legal scope)
Operating Altitude<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, 1000...4800 m with current derating 1 % per 100 m, <= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Temperature For Storage-40-70 °C
Environmental DisclosureENVPEP1406001EN
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep CodeENVPEP1406001EN
Pcr VersionPCR-ed3-EN-2015 04 02
General Attributes
- Phase
- 3 phase
- Range Of Product
- Altivar Process ATV600
Product Or Component Typevariable speed drive
Output Attributes
- Analogue Output Type
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
- Discrete Output Type
- relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mA, relay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA
- Analogue Output Number
- 2
- Maximum Output Frequency
- 500 kHz
- Nominal Output Current
- 31.7 A
- Output Voltage
- <= power supply voltage
- Speed Drive Output Frequency
- 0.1-500 Hz
Continuous Output Current23.5 A 4 kHz heavy duty, 31.7 A 4 kHz normal duty
Relay Output Typeconfigurable relay logic R2 sequence relay NO 100000 cycles, configurable relay logic R3 sequence relay NO 100000 cycles, configurable relay logic R1 fault relay NO/NC 100000 cycles
Discrete Output Number0
Maximum Output Voltage480.0 V
Nominal Output Power15.0 kW
Relay Output Number3
Surge Protection And Filtering Attributes
- EMC Filter
- integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Input Attributes
- Analogue Input Type
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
- Input Compatibility
- DI5, DI6 discrete input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2, DI1...DI6 discrete input level 1 PLC IEC 61131-2
- Discrete Input Number
- 8
- Number Of Input Phases
- 3
Discrete Input Logicpositive logic (source) DI1...DI8), < 5 V, > 11 V, negative logic (sink) DI1...DI8), > 16 V, < 10 V, 16 preset speeds
Analogue Input Number3
Discrete Input TypeDI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Specifications
- Depth
- 299 mm
Batteries & Runtime Attributes
- Removable Battery
- Yes
Downloads
Video
Similar Products
CAD$4245.68/ EA
Loading add to cart quantity...
Need assistance finding the right item?