Schneider Electric ATV650D15N4EU Altivar Process Variable Speed Drive, 15 kW, 400-480V, IP55


Schneider Electric ATV650D15N4EU Altivar Process Variable Speed Drive, 15 kW, 400-480V, IP55
- MPN: ATV650D15N4EU
- PPN: SCH-ATV650D15N4EU
- UNSPSC: 39122001
Spec sheet
Loading compare button...
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
CAD$4415.91/ EA
Description
Features
- Embedded power measurement and energy dashboard
- Embedded process monitoring and control
- Energy saving
- Asset monitoring and protection
- Drift monitoring
- Easy maintenance via a dynamic QR code
- Proven technical cooling and harmonic solutions
- Modular and compact design
- Easy grid integration
Specifications
Communications & Management Attributes
- Communication Port Protocol
- Ethernet, Modbus TCP
Conformance Attributes
- Product Certifications
- CSA, TÜV, ATEX INERIS, UL, ATEX zone 2/22
Complementary Attributes
- Maximum Horse Power Rating
- 15 hp heavy duty, 20 hp normal duty
- Maximum Thdi
- <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12
- Brake Chopper Integrated
- false
- Maximum Input Current Per Phase
- 27.0 A
- Maximum Output Voltage
- 480.0 V
Important Information Attributes
- Product Contributes To Saved And Avoided Emissions
- YES_SSI2, Yes
- Persona Type Names
- End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator
- Asynchronous Motor Control Profile
- constant torque standard, optimized torque mode, variable torque standard
- Electrical Connection
- line side screw terminal 10...16 mm², motor screw terminal 10...16 mm², control removable screw terminals 0.5...1.5 mm²
- EMC Filter
- integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
- Insulation Resistance
- > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth, > 1 MOhm 500 V DC for 1 minute to earth
- Linearity Error
- AO1, AO2 +/- 0.2 % analog output, AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
- Motor Power KW
- 11 kW heavy duty), 15 kW normal duty)
- Noise Level
- 53.7 dB 86/188/EEC, 53.7 dB
- Permissible Temporary Current Boost
- 1.5 x In 60 s heavy duty), 1.1 x In 60 s normal duty)
- Protection Type
- safe torque off drive, motor phase break drive, thermal protection motor, safe torque off motor, motor phase break motor, thermal protection drive, overheating drive, overcurrent between output phases and earth drive, overload of output voltage drive, short-circuit protection drive, overvoltages on the DC bus drive, line supply overvoltage drive, line supply undervoltage drive, line supply phase loss drive, overspeed drive, break on the control circuit drive
- Supply
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection, internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection, external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection
- Synchronous Motor Control Profile
- synchronous reluctance motor, permanent magnet motor
- Vibration Resistance
- 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6, 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
- Us Rated Supply Voltage2
- 380...480 V, 380...480 V - 15...10 %
- Environmental Class During Storage2
- class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
- Carbon Footprint Of The Distribution Phase A4
- 4.1028674925, 4 kg CO2 eq.
- Carbon Footprint Of The Installation Phase A5
- 7 kg CO2 eq., 7.3992929914
- Carbon Footprint Of The Use Phase B2 B3 B4 B6
- 14 801 kg CO2 eq., 14801.3780407012
- Environmental Class During Storage3
- class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
- Ue Rated Operational Voltage5
- 380...480 V 15 kW 20 hp normal duty, 380...480 V 11 kW 15 hp heavy duty
- Local Publishable Date
- 2026-01-12
- Serviceability
- Yes
- Field Service Division
- IDIBS
- Legacy WEEE Scope
- In
- EOLI Availability Display
- Yes
- Reach Full Compliance Status
- Reference contains Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Reference contains Substances of Very High Concern above the threshold
- ROHS EUR Status
- Compliant with Exemptions
- ROHS EUR Full Compliance Status Id
- PRO_ACTIVE_COMPLIANCE
- Green Premium Status For Reporting
- Green Premium product
- Without Single Use Plastic
- No
- Dangerous Goods Code
- LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
- Function Option
- Advanced
- Market Segmentation
- Industrial
- 4 Quadrant Operation Possible
- false
- Base Load Current At High Overload
- 23.5 A
- Braking To Standstill
- by DC injection
- Computer Port
- true
- Design Of Frequency Changer
- U converter
- Enclosure Mounting
- wall mounted
- Housing Material
- plastic
- Marking
- CE
- Maximum Input Current Per Phase
- 27.0 A
- Mounting Mode
- wall mount
- Nominal Switching Frequency
- 4 kHz
- Operating Element Present
- true
- Optical Interface Present
- false
- Package Weight Lbs
- 25.0 kg
- Power Loss Per Device Current Dependent
- 500.0 W
- Product Availability
- Non-Stock - Not normally stocked in distribution facility
- Product Specific Application
- process and utilities
- Range Of Product
- Altivar Process ATV600
- Regulation Loop
- adjustable PID regulator
- Relative Symmetric Network Frequency Tolerance
- 5 %
- Safety Function
- STO (safe torque off) SIL 3
- Supply Frequency
- 50...60 Hz - 5...5 %
- Supporting Protocol For Asi
- false
- Supporting Protocol For Can
- true
- Supporting Protocol For Devicenet
- false
- Supporting Protocol For Ethernet Ip
- true
- Supporting Protocol For Interbus
- false
- Supporting Protocol For Lon
- false
- Supporting Protocol For Other Bus Systems
- false
- Supporting Protocol For Profinet Cba
- true
- Supporting Protocol For Profisafe
- false
- Supporting Protocol For Sercos
- false
- Supporting Protocol For TCP IP
- true
- Total Lifecycle Carbon Footprint
- 15 041 kg CO2 eq.
- Type Of Cooling
- forced convection
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Emc Limit Value Complied2
- true
- Maximum Acceleration Under Shock Load During Storage2
- 150 m/s² at 11 ms
- Maximum Acceleration Under Vibrational Stress During Operation2
- 10 m/s² at 13...200 Hz
- Maximum Acceleration Under Vibratory Load During Transport2
- 10 m/s² at 13...200 Hz
- Maximum Deflection Under Vibratory Load During Storage2
- 1.5 mm at 2...13 Hz
- Permitted Relative Humidity During Operation2
- class 3K5 according to EN 60721-3
- Permitted Relative Humidity During Transport2
- class 2K5 according to EN 60721-3
- With Safety Function Safe Direction Sdi2
- false
- With Safety Function Safe Position Sp2
- false
- With Safety Function Safe Stop 1 SS1
- false
- With Safety Function Safely Limited Position Slp2
- false
- With Sft Fct Safe Stop 2 Ss
- false
- Supporting Protocol For Interbus Safety
- false
- Stocking Flag
- Y
- Emc Limit Value Complied3
- true
- Maximum Acceleration Under Shock Load During Storage3
- 150 m/s² at 11 ms
- Maximum Acceleration Under Vibrational Stress During Operation3
- 10 m/s² at 13...200 Hz
- Maximum Acceleration Under Vibratory Load During Transport3
- 10 m/s² at 13...200 Hz
- Maximum Deflection Under Vibratory Load During Storage3
- 1.5 mm at 2...13 Hz
- Permitted Relative Humidity During Operation3
- class 3K5 according to EN 60721-3
- Permitted Relative Humidity During Transport3
- class 2K5 according to EN 60721-3
- With Safety Function Safe Direction Sdi3
- false
- With Safety Function Safe Position Sp3
- false
- With Safety Function Safe Torque Off Sto3
- true
- With Safety Function Safely Limited Speed Sls3
- false
- Pep Code
- ENVPEP1406001EN
- Pep Verification Date
- 2021-11-01
- Type Of Verification For The Pep
- Independent external review
- Functional Unit Description
- To adapt the speed and torque of synchronous, asynchronous or reluctance motor to the machine s operating point for 22 kW electric motors for fluid management and industrial applications in IP55/UL type 1 conditions, at 380V to 480V rated 3-phase voltage supply, with disconnect switch. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 80% uptime in use phase at 75% loading rate and 20% uptime in stand by phase.
- Energy Model Manufacturing A1 A3 2
- Energy model used: China
- Energy Model Use B6 2
- Electricity Mix; AC; < 1kV; EU-27
- Global Commercial Status
- Commercialised
- With Safety Function Safe Stop 1 Ss1 5
- false
Environment Attributes Main
- Take Back
- Nej, No
- Ambient Air Transport Temperature
- -40-70 °C, -40-70 °C
- IP Degree Of Protection
- IP55, IP55IEC 60529, IP55IEC 61800-5-1
- ROHS Exemption Information
- Yes
- China ROHS Regulation
- X
- Carbon Footprint
- 15040.8129415712
- Circularity Profile
- ENVEOLI1406001EN
- Nema Degree Of Protection
- NEMA 12
- Packaging Without Single Use Plastic
- No
- Relative Humidity
- 5-95 % without condensation IEC 60068-2-3
- Pep Verification Date
- 2021-11-01
- Type Of Verification For The Pep
- Independent external review
General Attributes
- Phase
- 3 phase
- Range Of Product
- Altivar Process ATV600
Output Attributes
- Analogue Output Type
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits, software-configurable current AQ1, AQ2 0...20 mA 10 bits, software-configurable current DQ-, DQ+ 30 V DC, software-configurable current DQ-, DQ+ 100 mA
- Discrete Output Type
- relay outputs R2A, R2C 30 V DC 5000 mA, relay outputs R3A, R3C 30 V DC 5000 mA, relay outputs R1A, R1B, R1C 250 V AC 3000 mA, relay outputs R1A, R1B, R1C 30 V DC 3000 mA, relay outputs R2A, R2C 250 V AC 5000 mA, relay outputs R3A, R3C 250 V AC 5000 mA
- Analogue Output Number
- 2
- Maximum Output Frequency
- 500 kHz
- Nominal Output Current
- 31.7 A
- Output Voltage
- <= power supply voltage
- Speed Drive Output Frequency
- 0.1-500 Hz
Surge Protection And Filtering Attributes
- EMC Filter
- integrated 50 m IEC 61800-3 category C2, integrated 150 m IEC 61800-3 category C3
Input Attributes
- Analogue Input Type
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits, AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits, AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
- Input Compatibility
- DI5, DI6 discrete input level 1 PLC IEC 65A-68, STOA, STOB discrete input level 1 PLC IEC 61131-2, DI1...DI6 discrete input level 1 PLC IEC 61131-2
- Discrete Input Number
- 8
- Number Of Input Phases
- 3
Specifications
- Depth
- 330 mm
Batteries & Runtime Attributes
- Removable Battery
- Yes
Downloads
Video
Similar Products
Others Also Viewed
Loading carousel layout...
Loading carousel layout...
CAD$4415.91/ EA
Loading add to cart quantity...