Schneider Electric

Schneider Electric LC1K09008E7 TeSys K Contactor 4P (2NO+2NC) 20A 440V 48V AC Coil

  • MPN: LC1K09008E7
  • PPN: SCH-LC1K09008E7
  • UNSPSC: 39121529

CAD

$74.78

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 48V 50/60Hz AC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Features

  • TeSys K is a compact contactor range with a wide variety of coil voltage and terminal connection options
  • The offer features specific versions for railway (TeSys S207) and electrodomestic (TeSys S335) applications
  • One of the smallest contactor offerings in the market
  • The range delivers strong performance for its compact size and promises seamless integration in all applications.
  • Widely used for industry, infrastructure and building applications
  • Designed for simple control systems

Documentation & Downloads

Specifications

Key Specifications

Country of OriginIndonesia
Depth57 mm
Weight179 g

Complementary Attributes

Rated Breaking Capacity110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Ue Rated Operational Voltagepower circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
Control Circuit TypeAC 50/60 Hz
Irms Rated Making Capacity110 A AC for power circuit conforming to IEC 60947
Icw Rated Short Time Withstand Current90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit
Uimp Rated Impulse Withstand Voltage8 kV
Uc Control Circuit VoltageAC 50/60 Hz, 48 V
Ui Rated Insulation Voltagepower circuit 600 V UL 508power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA C22.2 No 14
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C)
Maximum Operating Rate3600 cyc/h
Ie Rated Operational Current20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Associated Fuse Rating25 A gG at <= 440 V for power circuit, 25 A aM for power circuit
Mechanical Robustnessshocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Operating Time10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing15...25 ms coil de-energisation and NC closing5...15 ms coil energisation and NC opening
Signalling Circuit Frequency<= 400 Hz, <= 400 Hz
Connections Terminals2 0.75-4 mm²flexible without cable end, 2 0.34-1.5 mm²flexible with cable endscrew clamp terminalsscrew clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable endscrew clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid
Ith Conventional Free Air Thermal Current20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
Carbon Footprint Of The End Of Life Phase C1 To C40.25761189519253946, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A30.9 kg CO2 eq., 0.9191500378989131
Local Data StatusPublishable
Return IndicatorN
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1503003
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2448
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologywithout built-in suppressor module
Contactor Applicationresistive load
Device Short NameLC1K
Heat Dissipation1.3-1.3 W
Mechanical Durability10 Mcycles
Overvoltage CategoryIII
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
RangeTeSys
ReturnabilityNo
Software Versionv6.2.4
Total Lifecycle Carbon Footprint58 kg CO2 eq.
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Data Sourceextrapolated product
Width Nominal45 mm
Customs Code8536490065
Rated Thermal Current Ith20 A
Functional Unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional Unit Unitunit
Recyclability Potential In %63
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Flame RetardanceV1 conforming to UL 94requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Mounting Supportrail, plate
Protective TreatmentTC IEC 60068, TC DIN 50016
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Certificate AgencyCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Carbon Footprint Of The Distribution Phase A40.35474462234016035, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50 kg CO2 eq., 0.02438721956318318
Carbon Footprint Of The Use Phase B2 B3 B4 B657 kg CO2 eq., 56.65241524409137
Local Publishable Date2026-06-27
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Compatibility CodeLC1K
Device Applicationcontrol
Electrical Durability0.16 Mcycles 20 A AC-1 <= 690 V
Inrush Power In Va30-30 VA (at 20 °C)
Number Of Poles4P
Pole Contact Composition2 NO + 2 NC
Product Or Component Typecontactor
Range Of ProductTeSys K
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Sustainable PackagingYes
Utilisation CategoryAC-1
Database Version2024-01
Height Nominal58 mm
Nbr. Of Units In Pkg.1
Hold In Power Consumption In Va4.5-4.5 VA (at 20 °C)
Warranty In Months18
Functional Unit Quantity1
Reference Lifetime In Y20

Environment Attributes Main

Ambient Air Temperature For Storage-50-80 °C, -50-80 °C
Reach Free ShvcYes
China Rohs RegulationX
Mercury FreeYes
Circularity ProfileENVEOLI1503003
Eu Rohs DirectiveCompliant
Operating Altitude6561.68 ft (2000 m) without derating
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-23
Psr VersionPSR-0005-ed3-2023 06 06
Take BackNo
Recycled Metal Content At Cr Level0 %
Toxic Heavy Metal FreeYes
Carbon Footprint58.208309019086165
Environmental DisclosureENVPEP1503003EN
Ip Degree Of ProtectionIP2X VDE 0106
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1503003EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Typecontactor
Range Of ProductTeSys K

ETIM

ETIM 8EC000066
ETIM 10EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty18 months
TeSys K Contactor 4P (2NO+2NC) 20A 440V 48V AC Coil
Loading video…

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$74.78/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!