Schneider Electric LC1K0610G7 TeSys K Contactor 3P 6A 120V AC Coil, 45mm Width
- MPN: LC1K0610G7
- PPN: SCH-LC1K0610G7
CAD
$53.68
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Features
- Measuring just 45mm in width and 58mm in height, this ultra-compact TeSys K series motor contactor features one of the smallest physical footprints on the industrial market. It integrates seamlessly into tightly packed automation enclosures and distribution panels, maximizing your remaining DIN rail space and preventing the need to specify a larger, more costly cabinet footprint.
- Engineered with a 3-pole Normally Open (3 NO) power contact configuration, this device reliably switches inductive operational currents up to 6A under AC-3 and AC-3e utilization categories. It delivers optimized motor management capacity up to 2.2 kW at 380-415V or 3 kW at 440V, allowing industrial electricians to establish dependable Direct-On-Line (DOL) starters for small asynchronous pumps, conveyors, and automated fans.
- Equipped with a standard 120V AC control coil optimized for both 50 Hz and 60 Hz frequencies, this device integrates directly into common North American plant control loops and transformer circuits. The robust coil design features a secure drop-out threshold of 0.2 and holds in at a highly efficient 4.5 VA, preventing excessive localized heat generation while safely absorbing momentary line drops to avoid nuisance machinery downtime.
- Built with a factory-integrated, instantaneous Normally Open (1 NO) auxiliary contact block, this controller eliminates the cost and space of installing add-on signaling contacts. Operating down to a minimum switching threshold of 17V at 5mA, it guarantees precise, low-energy state feedback to your primary programmable logic controllers or status pilot lights for reliable plant-floor safety monitoring.
- Boasting an exceptional mechanical durability rating of up to 10 million cycles alongside 1.3 million electrical cycles at full AC-3 load, this industrial-grade component drastically lowers future replacement intervals.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, Costa Rica, France, Indonesia, United States |
|---|
| Depth | 57 mm |
|---|
Complementary Attributes
| Irms Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
|---|---|
| Control Circuit Type | AC 50/60 Hz |
| Maximum Motor Phase Current | 6 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
|---|---|
| Control Circuit Voltage Limits | operational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C) |
| Maximum Operating Rate | 3600 cyc/h |
| Minimum Switching Voltage | 17 V for signalling circuit |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
| Flame Retardance | V1 conforming to UL 94requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102 |
| Mechanical Robustness | shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 |
| Mounting Support | plate, rail |
| Protective Treatment | TC IEC 60068, TC DIN 50016 |
| Tightening Torque | 0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2 |
| Certificate Agency | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
| [Ie] Rated Operational Current | 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| [Uc] Control Circuit Voltage | AC 50/60 Hz, 120 V |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V UL 508signalling circuit 600 V CSA C22.2 No 14power circuit 600 V UL 508power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-5-1, power circuit 600 V CSA C22.2 No 14 |
| Carbon Footprint Of The Distribution Phase [A4] | 0.35672643587278696, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase [A5] | 0 kg CO2 eq., 0.024523461013256826 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 57 kg CO2 eq., 56.65241524409139 |
| Local Publishable Date | 2026-06-27 |
| Stocking Flag | N |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Compatibility Code | LC1K |
| Device Application | control |
| Heat Dissipation | 1.3-1.3 W |
| Mechanical Durability | 10 Mcycles |
| Number Of Poles | 3P |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys K |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Database Version | 2024-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Functional-unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 140.16 |
| Energy Model - Installation [A5] | No energy used |
| Energy Model - End Of Life [C1-c4] | Global, European and French datasets are used. |
| Height Nominal | 58 mm |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536490065 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Electrical Durability | 1.3 Mcycles 6 A AC-3 <= 440 V, 1.3 Mcycles 6 A AC-3e <= 440 V, 0.05 Mcycles 36 A AC-4 <= 440 V |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 2.2 kW 380...415 V AC 50/60 Hz AC-3e, 3 kW 440/690 V AC 50/60 Hz AC-3e2.2 kW 380...415 V AC 50/60 Hz AC-4, 3 kW 440/690 V AC 50/60 Hz AC-41.5 kW 220...230 V AC 50/60 Hz AC-32.2 kW 380...415 V AC 50/60 Hz AC-33 kW 440/690 V AC 50/60 Hz AC-3, 1.5 kW 220...230 V AC 50/60 Hz AC-3e, 1.5 kW 220...230 V AC 50/60 Hz AC-4 |
| Operating Time | 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing |
| Signalling Circuit Frequency | <= 400 Hz, <= 400 Hz |
| Utilisation Category | AC-3, AC-3e, AC-4 |
| [Icw] Rated Short-time Withstand Current | 90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit |
| [Ith] Conventional Free Air Thermal Current | 20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz |
| Connections - Terminals | 2 0.75-4 mm²flexible without cable end, 2 0.34-1.5 mm²flexible with cable endscrew clamp terminalsscrew clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable endscrew clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid |
| Carbon Footprint Of The End-of-life Phase [C1 To C4] | 0.25905106779138043, 0.3 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 0.9 kg CO2 eq., 0.9242849543117562 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1503003 |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 2448 |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Coil Technology | without built-in suppressor module |
| Contactor Application | motor control |
| Device Short Name | LC1K |
| Inrush Power In Va | 30-30 VA (at 20 °C) |
| Non Overlap Distance | 0.5 mm |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Range | TeSys |
| Returnability | Yes |
| Software Version | v6.2.4 |
| Total Lifecycle Carbon Footprint | 58 kg CO2 eq. |
| Pep Code | ENVPEP1503003EN |
| Pep Verification Date | 2026-03-23 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Low voltage; 2020; France, FR |
| Energy Model - Use [B6] | Electricity Mix; Low voltage; 2020; Europe, EU-27 |
| Recyclability Potential In % | 63 |
| Width Nominal | 45 mm |
| Hold-in Power Consumption In Va | 4.5-4.5 VA (at 20 °C) |
| Package Weight(Lbs) | 180.000 g |
| Warranty (In Months) | 18 |
Environment Attributes Main
| Ambient Air Temperature For Storage | -50-80 °C, -50-80 °C |
|---|---|
| Reach Free Shvc | Yes |
| China Rohs Regulation | X |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1503003 |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 6561.68 ft (2000 m) without derating |
| Packaging Without Single Use Plastic | Yes |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-23 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Take Back | No |
|---|---|
| Recycled Metal Content At Cr Level | 0 % |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 58.21700116308057 |
| Environmental Disclosure | ENVPEP1503003EN |
| Ip Degree Of Protection | IP2X VDE 0106 |
| Packaging Made With Recycled Cardboard | Yes |
| Reach Free Of Svhc | Yes |
| Pep Code | ENVPEP1503003EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys K |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|



Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$53.68
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$53.68/ EA