Tripp Lite SUINT3000XLCD SmartOnline 230V 3000VA 2700W On-Line Double-Conversion UPS, Tower, 11.2 min Runtime





Tripp Lite SUINT3000XLCD SmartOnline 230V 3000VA 2700W On-Line Double-Conversion UPS, Tower, 11.2 min Runtime
- MPN: SUINT3000XLCD
- UPC: 037332194916
- PPN: TRP-SUINT3000XLCD
Spec sheet
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
CAD$3759.41/ EA
Description
Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise. Recommended for small/medium servers, networking equipment and telecom systems.
Features
- Zero transfer time suitable for advanced network applications
- 2% output voltage regulation in online, double-conversion mode
- Expandable runtime with optional external battery packs
- Interactive LED/LCD status display
- 11.2 min. runtime at half load; 4.4 min. at full load
- 2-year limited warranty
Specifications
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 425
- EMI / RFI AC Noise Suppression
- Yes
UPS AC Suppression Response TimeInstantaneous
Battery
- Full Load Runtime (min.)
- 4.4 min. (2700w)
- Expandable Battery Runtime
- Extended runtime supported via optional external battery packs
- Expandable Runtime Description
- External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
- Battery Recharge Rate (Included Batteries)
- Less than 6 hours from 10% to 90% (typical, full load discharge)
Half Load Runtime (min.)11.2 min. (1350w)
External Battery Pack CompatibilityBP72V15-2U (limit 1); BP72V18 -2US (multi-pack compatible); BP72V28RT-3U (multi-pack compatible)
DC System Voltage (VDC)72
Expandable RuntimeYes
Certifications
- UPS Certifications
- CE
UPS Certification DetailsEN62040-2:2006; IEC 62040-1:2008+A1:2013; ESD:IEC61000-4-2:LEVEL 4, RS:IEC61000-4-3:LEVEL 3, EFT:IEC61000-4-4:LEVEL 2, SURGE: IEC61000-4-5:LEVEL 2, CS:IEC61000-4-6:LEVEL 3, CONDUCTED MAGNETIC FIELD: IEC61000-4-8:LEVEL 4
Physical
- Cooling Method
- Fan
- Primary UPS Depth (mm)
- 361
- Primary UPS Width (mm)
- 191
- Shipping Weight (lbs.)
- 53.62
- UPS Power Module Dimensions (hwd, in.)
- 12.8 x 7.5 x 14.2
- UPS Power Module Weight (lbs.)
- 54.8
Primary Form FactorTower
Primary UPS Height (mm)325
Shipping Dimensions (hwd / in.)17.20 x 11.80 x 19.30
UPS Housing MaterialSteel
UPS Power Module Weight (kg)24.86
User Interface, Alerts & Controls
- Front Panel LCD Display
- Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional information
- Alarm Cancel Operation
- Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
SwitchesON switch supports inverter-on, battery-test, alarm-off and enter functions; OFF switch supports inverter-off and fault-clear functions; SETUP switch enables scroll-down and enter setup-mode functions
Audible AlarmAudible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Voltage Regulation
- Voltage Regulation Description
- Online, double-conversion power conditioning
- Undervoltage Correction
- 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)
Overvoltage Correction2% output voltage regulation during overvoltages to 280
Input
- Rated input current (Maximum Load)
- 14.6A 220V; 14.0A 230V; 13.4A 240V
- Nominal Input Voltage Description
- 230V factory default
- Input Circuit Breakers
- 20A
- Recommended Electrical Service
- 230V
Nominal Input Voltage(s) Supported220V AC; 230V AC; 240V AC
UPS Input Connection TypeC20 inlet
UPS Input Cord Length (ft.)10
Input PhaseSingle-Phase
Output
- Output Volt Amp Capacity (VA)
- 3000
- Output Watt Capacity (Watts)
- 2700
- Power Factor
- 0.9
- Nominal Voltage Details
- 230V default
- Frequency Compatibility Details
- ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.
- Output Voltage Regulation (Economy Line Mode)
- +/- 10%
- Included Output Power Cables
- Includes three C13 to C14 power cables
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Nominal Output Voltage(s) Supported
- 220V; 230V; 240V
- Individually Controllable Load Banks
- No
Output kVA Capacity (kVA)3
Output kW Capacity (kW)2.7
Crest Factor3:1
Frequency Compatibility50 / 60 Hz
Output Voltage Regulation (Line Mode)+/- 2%
Output Voltage Regulation (Battery Mode)+/- 3%
Output AC Waveform (AC Mode)Pure Sine wave
Output Capacity DetailsOVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits)
Output Receptacles(6) C13; (1) C19
Communications
- Network Management Cards
- SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Interface
- DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled)
Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions
Communications CableUSB and DB9 cabling included
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- AC Economy Mode BTU / Hr. (Full Load)
- 188
- AC Mode Efficiency Rating (100% Load)
- 92%
- Operating Elevation (ft.)
- 0-3000ft
- Operating Elevation (m)
- 0-1000m
Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
AC Mode BTU / Hr. (Full Load)818
Battery Mode BTU / Hr. (Full Load)1538
AC Economy Mode Efficiency Rating (100% Load)98%
Audible Noise< 52 dB at front side 1m
Overview
- UPC Code
- 037332194916
UPS TypeOn-Line
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- Green Energy-Saving Features
- High efficiency economy mode operation
High Availability UPS FeaturesAutomatic inverter bypass; Hot swappable batteries
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
Line / Battery Transfer
- Transfer Time
- Zero transfer time (0 ms.)
- High Voltage Transfer to Battery Power (Setpoint)
- 280
Low Voltage Transfer to Battery Power (Setpoint)80V (<50% load), 175V (100% load)