Tripp Lite SU12KRT4UHW 12kVA 10.8kW Online Double-Conversion UPS, 8U Rackmount, Expandable Runtime




Tripp Lite SU12KRT4UHW 12kVA 10.8kW Online Double-Conversion UPS, 8U Rackmount, Expandable Runtime
- MPN: SU12KRT4UHW
- UPC: 037332157119
- PPN: TRP-SU12KRT4UHW
Spec sheet
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
Features
- 12kVA / 12,000VA / 10,800 watt on-line double-conversion 8U rack/tower UPS
- 200/208/220/230/240V +/-2% 50/60Hz output
- Hot-swap power & battery modules, N+1 fault tolerance at loads up to 6kVA
- USB, RS232, EPO ports, Slot for Network Management Card options
- Front panel LEDs, Detailed LCD monitoring and control screen
- Expandable runtime with optional external battery packs
- 2-year limited warranty
Specifications
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 2595
- EMI / RFI AC Noise Suppression
- Yes
UPS AC Suppression Response TimeInstantaneous
Battery
- Full Load Runtime (min.)
- 2 minutes (10,800 watts)
- Expandable Battery Runtime
- Runtime is expandable with external battery packs
- Expandable Runtime Description
- For best results, add external batteries in multiples of two so that both included 6kVA power modules have an equal number and type of connected battery packs
- Battery Recharge Rate (Included Batteries)
- Less than 6 hours from 10% to 90% (typical, full load discharge)
- Battery Access
- Front panel battery access door
- Expandable Runtime
- Yes
Half Load Runtime (min.)8.5 minutes (5400 watts)
External Battery Pack CompatibilityBP192V12-3U ; BP192V787C-1PH
DC System Voltage (VDC)192
Internal UPS Replacement Battery CartridgeEach of the two included 6kVA power modules contain one RBC5-192 internal replacement battery cartridge
Battery Replacement DescriptionHot-swappable, user replaceable internal battery cartridges and external battery packs
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
UPS Certification DetailsIEC 61000-4-5 1995 B Surge Immunity
Physical
- Cooling Method
- Fans
- Installation Form Factors Supported with Included Accessories
- 4 post 19 inch rackmount
- Maximum Device Depth (in.)
- 24
- Optional Mounting Accessory Notes
- Qty 2 2POSTRMKITHD required for 2 post rackmount installation of all included components
- Primary UPS Depth (mm)
- 526
- Primary UPS Width (mm)
- 445
- Shipping Dimensions (hwd / in.)
- 41.00 x 24.00 x 34.00
- UPS Dimensions Details
- Includes two 4U UPS/power modules plus SUPDMB12HW detachable parallel bypass PDU; UPS Power Module Dimensions are for one of the two included UPS/power modules; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
- UPS Power Module Dimensions (hwd, in.)
- 6.85 x 17.5 x 20.7
- UPS Power Module Weight (lbs.)
- 108
Included Mounting Accessory DescriptionIncludes 4 post mounting accessories for each included component
Installation Form Factors Supported with Optional Accessories2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )
Minimum Required Rack Depth (inches)35.2
Primary Form FactorRackmount
Primary UPS Height (mm)174
Rack Height8U
Shipping Weight (lbs.)342.00
UPS Housing MaterialSteel
UPS Power Module Weight (kg)48.99
User Interface, Alerts & Controls
- Front Panel LCD Display
- Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
- Alarm Cancel Operation
- Alarm cancel switch
- LED Indicators
- 6 LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
SwitchesIncludes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
Audible AlarmUnique audible alarms for all major UPS, environmental and power conditions (see manual)
Voltage Regulation
- Voltage Regulation Description
- +/-2% output voltage regulation in standard online, double-conversion mode
- Undervoltage Correction
- Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
Overvoltage CorrectionCorrects overvoltages as high as 300V (<90% load) and 280V (full load)
Input
- Rated input current (Maximum Load)
- 63.8A (200V), 61.2A (208V), 58A (220V), 55.4A (230V), 53.2A (240V)
- UPS Input Connection Type
- Hardwire
- Recommended Electrical Service
- 70A
Nominal Input Voltage(s) Supported200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection DescriptionSupports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
Input PhaseSingle-Phase
Output
- Output Volt Amp Capacity (VA)
- 12000
- Output Watt Capacity (Watts)
- 10800
- Power Factor
- 0,9
- Nominal Voltage Details
- Voltage selection via front panel LCD interface
- Frequency Compatibility Details
- Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output Capacity Details
- Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
- Output Receptacles
- Hardwire
Output kVA Capacity (kVA)12
Output kW Capacity (kW)10.8
Crest Factor3:1
Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Output Voltage Regulation (Line Mode)+/- 2%
Output Receptacle DetailsSupports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
Output AC Waveform (Battery Mode)Pure Sine wave
Nominal Output Voltage(s) Supported200V; 208V; 220V; 230V; 240V
Individually Controllable Load BanksNo
Communications
- Network Management Cards
- SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- WatchDog Compatibility
- Yes
Network Monitoring Port DescriptionApplications utilizing any supported network management card option, require the use of two network cards of the same-model (install one card per included UPS power module); RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module
Communications CableUSB, DB9 serial and EPO cables included
Communications InterfaceUSB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
- Relative Humidity
- 0 to 95%, non-condensing
- Battery Mode BTU / Hr. (Full Load)
- 4558
- Operating Elevation (ft.)
- 0-3000m (0 to 10,000 ft.)
- Operating Elevation (m)
- 0-3000 m
Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
AC Mode BTU / Hr. (Full Load)3534
AC Mode Efficiency Rating (100% Load)90%
Audible Noise60 dBA at front side 1 meter
Overview
- UPC Code
- 037332157119
UPS TypeOn-Line
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- Green Energy-Saving Features
- Support for daily startup and shutoff
High Availability UPS FeaturesAutomatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
Line / Battery Transfer
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode
- High Voltage Transfer to Battery Power (Setpoint)
- 280V (full load) / 300V (90% load or less)
Low Voltage Transfer to Battery Power (Setpoint)156V (full load) / 100V (50% load or less, derates linearly)