Tripp Lite

Tripp Lite SMX700HG Medical-Grade 700VA Tower UPS with 6 Outlets, USB, and Full Isolation

  • MPN: SMX700HG
  • UPC: 037332140418
  • PPN: TRP-SMX700HG

CAD

$1685.23

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

SmartPro 230V 700VA 450W Medical-Grade Line-Interactive Tower UPS with 6 Outlets, Full Isolation, USB, DB9

Features

  • USB monitoring cable, 1.8 m (6 ft.)
  • DB9 serial monitoring cable, 1.8 m (6 ft.)
  • Owner's Manual

Documentation & Downloads

Specifications

Additional

Capacity700 VA, 450 W
Runtime Half Load36 minutes at 225 W
Surge Suppression340 joules
Plug TypeIEC320 C14 hospital-grade
Voltage RegulationCorrects brownouts 155 to 274V
Output Volt Amp Capacity700 VA
APS AC Suppression Joule Rating340
Input PhaseSingle-Phase
UPS Input Cord Length0.5 ft.
DC System Voltage36 VDC
AC Mode BTU/hr. (Full Load)208.6
Severe Undervoltage CorrectionInput 155-182 V boosted 21%
Recommended Electrical Service10A 230V
Grounding LugEquipotential connection (back panel grounding lug)
Communications InterfaceUSB; DB9 Serial
Primary UPS Depth229 mm
Shipping Dimensions (H x W x D)18.5 x 12.2 x 13.38 in.
UPS CertificationsUL 60601-1, EN60601-1-2:2015 4th Edition, CE
UPS Power Module Weight42.1 lbs. / 19.1 kg
Storage Temperature Range5 to 122 F / -15 to 50 C
Battery AccessHot swap replacement without power off
Primary UPS Width191 mm
Frequency Compatibility50 / 60 Hz, automatic frequency selection
Nominal Output Voltage Supported220 V, 230 V, 240 V
AC Suppression Response TimeInstantaneous
Rated Input Current (Maximum Load)3.6 A
Undervoltage CorrectionInput 183-199 V boosted 10%
Relative Humidity0 to 95%, non-condensing
Primary Form FactorTower
Installation Form Factors SupportedWallmount (with optional UPSWM kit)
Product Warranty Period2-year limited warranty
Output Voltage230 V nominal
Runtime Full Load14.5 minutes at 450 W
Output Receptacles6 IEC320 C13 hospital-grade
IsolationFull isolation with built-in isolation transformer and Faraday shield
Leakage CurrentLess than 100 microamps
Voltage Compatibility230 V
UPS TypeLine-Interactive
Battery Recharge RateLess than 3.6 hours from 10% to 90% (typical, full load discharge)
Operating Temperature Range32 to 104 F / 0 to 40 C
Switches2 front panel push-button for system enable, self-test, alarm cancel
Cooling MethodRear-exit cooling fan
Internal UPS Replacement Battery CartridgeRBC36SLT
Output AC WaveformPWM sine wave
Low Voltage Transfer to Battery Power155 V
Typical Battery Lifespan3-6 years depending on usage
Primary UPS Height325 mm
Voltage Regulation DescriptionLine interactive UPS with 2 brownout boost levels and 1 overvoltage adjustment across 155-274 V AC
Expandable RuntimeNo
High Voltage Transfer to Battery Power274 V
Transfer Time5 milliseconds
UPS Input Connection TypeC14 inlet
Overvoltage CorrectionInput 206-245 V AC reduced 9%
Output Voltage Regulation (Line Mode)-18% to +8%
Cold StartSupported
Nominal Input Voltage Supported230 V AC
UPS Power Module Dimensions (H x W x D)12.8 x 7.5 x 9 in.
UPS Housing MaterialPVC
EMI / RFI AC Noise SuppressionYes
LED Indicators5 LEDs for power, battery, overload, voltage regulation, battery status
Audible Alarm3-function alarm for power failure, overload, low battery; factory muted
Medical-Grade 700VA Tower UPS with 6 Outlets, USB, and Full Isolation
Medical-Grade 700VA Tower UPS with 6 Outlets, USB, and Full Isolation

Similar Products

Loading carousel layout...

CAD$1685.23/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!