TeSys U standard control unit to be inserted in power bases LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V. It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine).

Documentation & Downloads

Specifications

Key Specifications

Country of OriginBrazil, Costa Rica, France, United States
Depth60 mm

Complementary Attributes

Control Circuit Voltage Limits55 V DC 110...220 V drop-out, 88...264 V AC 110...240 V in operation, 88...242 V DC 110...220 V in operation55 V AC 110...240 V drop-out

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Device Applicationmotor control, motor protection
Function Availableearth fault protection, protection against phase failure and phase imbalance, protection against overload and short-circuit, manual reset
Motor Power Kw15 kW 400...440 V AC 50/60 Hz, 15 kW 500 V AC 50/60 Hz18.5 kW 690 V AC 50/60 Hz
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Thermal Overload Classclass 10 40-60 Hz -25-70 °C IEC 60947-6-2, class 10 40-60 Hz -25-70 °C UL 508
Utilisation CategoryAC-43, AC-41, AC-44
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Carbon Footprint Of The End-of-life Phase [C1 To C4]0.31296898800484324, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]1 kg CO2 eq., 1.1947135351162859
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ApplicabilityFinished product
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
China Rohs Label7
Without Single Use PlasticYes
Tier Id2
Function Option IdSTANDARD
Product Kit IdentifierN
Device Short NameLUCA
Fixing Modeplug-in (front face)
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Load Type3-phase motor self-cooled
Phase Failure Sensitivityyes
Product NameTeSys Ultra
Product Specific Applicationbasic protection requirements for motor starters: overload and short-circuit
RangeTeSys
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-28 kV 4 on contact IEC 61000-4-2
ReturnabilityYes
Software Versionv6.1
Thermal Protection Adjustment Range8-32 A
Tripping Threshold14.2 x Ir +/- 20 %
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
R Thermal Protection Adj Range8-32 A
Control Circuit Voltage 3 Control Circuit TypeDC
Pep CodeENVPEP2406038EN
Pep Verification Date2024-06-01
Psr VersionPSR-0005-ed3.1-EN-2023 12 08
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2018; France, FR
Recyclability Potential In %56
Width Nominal45 mm
[Ue] Rated Operational Voltage690 V AC
Non-dissipating Shock Wave1 kV serial mode IEC 60947-6-22 kV common mode IEC 60947-6-2
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536304000
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
Market SegmentationCommercial, Industrial
Fire Resistance960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
Heat Dissipation3-3 W control circuit with LUB32, 3-3 W control circuit with LUB38
Operating Time50 ms closing with LUB38 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit50 ms closing with LUB32 control circuit
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Typical Current Consumption280 mA 110...220 V DC I maximum while closing with LUB3825 mA 110...240 V AC I rms sealed with LUB38, 25 mA 110...220 V DC I rms sealed with LUB32, 25 mA 110...220 V DC I rms sealed with LUB38, 280 mA 110...240 V AC I maximum while closing with LUB32, 280 mA 110...240 V AC I maximum while closing with LUB38280 mA 110...220 V DC I maximum while closing with LUB3225 mA 110...240 V AC I rms sealed with LUB32
Certificate AgencyCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Carbon Footprint Of The Distribution Phase [A4]0.06838356635823767, 0.1 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0 kg CO2 eq., 0.009708208612935209
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]18 kg CO2 eq., 18.290275694507795
Local Publishable Date2026-06-27
Stocking FlagN
Device TypeRelay, Control & Measurement - measuring, monitoring device
TraceabilityYes
Average Life Duration15 year(s)
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI2406038EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1927
China Rohs In ScopeYes
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier2
Function OptionStandard
Compatibility CodeLUCA
Energy Efficiency OptimizedFalse
Immunity To Microbreaks3 ms
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Network Frequency40...60 Hz
Product AvailabilityStock - Normally stocked in distribution facility
Product Or Component Typestandard control unit
Protective TreatmentTH IEC 60068
Range Of ProductTeSys Ultra
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Shock Resistance10 gn power poles open IEC 60068-2-2715 gn power poles closed IEC 60068-2-27
Sustainable PackagingYes
Total Lifecycle Carbon Footprint20 kg CO2 eq.
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-64 gn 5-300 Hz power poles closed IEC 60068-2-6
Pop DirectiveNo POPs
Control Circuit Voltage 3 Control Circuit Voltage110...220 V
Load Type 6 Load Type3-phase motor
Database Version2023-02
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent external review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh273.75
Energy Model - Installation [A5]Electricity Mix; Low voltage; 2018; France, FR
Energy Model - End Of Life [C1-c4]Electricity Mix; Low voltage; 2018; France, FR
Height Nominal66 mm
[Uc] Control Circuit Voltage110...240 V AC110...220 V DC
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Halogen-free StatusHalogen free plastic parts product
Package Weight(Lbs)128.000 g
Warranty (In Months)18

Environment Attributes Main

Ambient Air Temperature For Storage-40-85 °C, -40-85 °C
Product Compatibilitypower base LUB32, power base LUB38, power base LUB320, power base LUB380reversing contactor breaker LU2B32FU, reversing contactor breaker LU2B38FU
Halogene PerformanceHalogen free plastic parts product
China Rohs RegulationX
Carbon Footprint19.876049992600098
Circularity ProfileENVEOLI2406038EN
Eu Rohs DirectiveCompliant By Exemption
Operating Altitude6561.68 ft (2000 m)
Packaging Without Single Use PlasticYes
Pep CodeENVPEP2406038EN
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent external review
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1IP40 front panel outside connection zone IEC 60947-1
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Temperature For Operation-25-70 °C-25-70 °C
Environmental DisclosureENVPEP2406038EN
Halogen Content PerformanceHalogen free plastic parts product
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2024-06-01
Psr VersionPSR-0005-ed3.1-EN-2023 12 08

General Attributes

Product Or Component Typestandard control unit
Range Of ProductTeSys Ultra

ETIM

ETIM 8EC000617
ETIM 9EC000617

Contractual Warranty Attributes

Warranty Period18 months
Warranty18 months
TeSys Ultra Standard Control Unit 8-32A 690VAC 3-Phase with Thermal Protection

Similar Products

Loading carousel layout...

CAD$227.22/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!