Documentation & Downloads

Schneider Electric LC1DT20E7 TeSys D Contactor 4P 20A 440V 48V AC Coil
- MPN: LC1DT20E7
- PPN: SCH-LC1DT20E7
CAD
$198.92
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Looking to buy a large quantity?
To view product inventory
Spec sheet
Description
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Indonesia
Complementary Attributes
- Control Circuit Type
- AC 50/60 Hz, AC 50/60 Hz
- Irms Rated Making Capacity
- 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A at 440 V for power circuit conforming to IEC 60947
- Minimum Switching Current
- 5 mA for signalling circuit
- Rated Breaking Capacity
- 250 A at 440 V for power circuit conforming to IEC 60947
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Associated Fuse Rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at <= 690 V coordination type 1 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit
- Insulation Resistance
- > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Mounting Support
- rail, plate
- Range
- TeSys, TeSys Deca
- Tightening Torque
- power circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals pozidriv No 2control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
- [Icw] Rated Short-time Withstand Current
- 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
- [Uc] Control Circuit Voltage
- 48 V, 48 V AC 50/60 Hz
- [Ui] Rated Insulation Voltage
- signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1
- Hold-in Power Consumption In Va
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
- Carbon Footprint Of The Distribution Phase [A4]
- 0.16917571616661592, 0.2 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase [A1 To A3]
- 2 kg CO2 eq., 1.5136785647517297
- Local Data Status
- Publishable
- Return Indicator
- N
- Stock Policy
- 2
- Serviceability
- No
- Field Service Division
- PPIBS
- Weee Scope
- In
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI1501004
- Reach Full Compliance Status Id
- NOT_CONTAINING_SVHC
- Rohs Eur In Scope
- Yes
- Rohs Eur Conformity Date
- 2538
- China Rohs In Scope
- No
- With Recycled Cardboard
- Yes
- Product Contributes To Saved And Avoided Emissions
- No
- Tier
- 1
- Function Option
- Standard
- Average Impedance
- 2.5 mOhm - Ith 20 A 50 Hz for power circuit
- Compatibility Code
- LC1D
- Contactor Application
- resistive load
- Fire Resistance
- 850 °C IEC 60695-2-1
- Heat Dissipation
- 2-3 W at 50/60 Hz
- Number Of Poles
- 4P
- Pole Contact Composition
- 4 NO
- Product Availability
- Non-Stock - Not normally stocked in distribution facility
- Protective Treatment
- THIEC 60068-2-30
- Returnability
- No
- Software Version
- v6.2.4
- Total Lifecycle Carbon Footprint
- 34 kg CO2 eq.
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Control Circuit Voltage
- 48 V
- Pep Code
- ENVPEP1501004EN
- Pep Verification Date
- 2026-03-17
- Psr Version
- PSR-0005-ed3-2023 06 06
- Data Source
- extrapolated product
- Functional-unit Quantity
- 1
- Reference Lifetime, In Y
- 20
- Energy Model - Installation [A5]
- No energy used
- Energy Model - End Of Life [C1-c4]
- Global, European and French datasets are used.
- Height Nominal
- 85 mm
- [Ie] Rated Operational Current
- 20 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
- Rated Thermal Current (Ith)
- 20 A
- Package Weight(Lbs)
- 389.000 g
- Warranty (In Months)
- 18
Environment Attributes Main
- China Rohs Regulation
- Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
- Permissible Ambient Air Temperature Around The Device
- -40-60 °C-40-60 °C, 60-70 °C with derating
- Reach Free Shvc
- Yes
- Toxic Heavy Metal Free
- Yes
- Carbon Footprint
- 33.73149062542807
- Environmental Disclosure
- ENVPEP1501004EN
- Ip Degree Of Protection
- IP20 front face IEC 60529
- Packaging Made With Recycled Cardboard
- Yes
- Reach Free Of Svhc
- Yes
- Pep Code
- ENVPEP1501004EN
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$198.92
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$198.92/ EA
Loading add to cart quantity...