Documentation & Downloads

Schneider Electric LUCD12B TeSys Ultra Control Unit, 3-Phase, 3-12A, 690V AC, Class 20
- MPN: LUCD12B
- PPN: SCH-LUCD12B
CAD
$284.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Looking to buy a large quantity?
To view product inventory
Spec sheet
Description
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Brazil, France
Complementary Attributes
- Control Circuit Voltage Limits
- 20...26.5 V AC 24 V in operation, 14.5 V AC 24 V drop-out
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Device Application
- motor control, motor protection
- Function Available
- earth fault protection, protection against phase failure and phase imbalance, protection against overload and short-circuit, manual reset
- Motor Power Kw
- 5.5 kW 400...440 V AC 50/60 Hz, 5.5 kW 500 V AC 50/60 Hz, 9 kW 690 V AC 50/60 Hz
- Resistance To Electrostatic Discharge
- 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
- Safe Separation Of Circuit
- 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Thermal Overload Class
- class 20 40-60 Hz -25-70 °C IEC 60947-6-2, class 20 40-60 Hz -25-70 °C UL 508
- Utilisation Category
- AC-44, AC-43, AC-41
- Certificate Agency
- CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
- Non-dissipating Shock Wave
- 1 kV serial mode IEC 60947-6-2, 2 kV common mode IEC 60947-6-2
- Carbon Footprint Of The End-of-life Phase [C1 To C4]
- 0.3007436369109041, 0.3 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase [A1 To A3]
- 1 kg CO2 eq., 1.148045037650806
- Local Data Status
- Publishable
- Return Indicator
- N
- Stock Policy
- 2
- Serviceability
- No
- Field Service Division
- PPIBS
- Weee Applicability
- Finished product
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Reference contains Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Reference contains Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant By Exemption
- Rohs Eur Full Compliance Status
- Compliant By Exemption
- China Rohs Label
- 7
- Without Single Use Plastic
- Yes
- Tier Id
- 2
- Function Option Id
- STANDARD
- Product Kit Identifier
- N
- Device Short Name
- LUCD
- Fixing Mode
- plug-in (front face)
- Immunity To Radioelectric Fields
- 10 V IEC 61000-4-6
- Load Type
- 3-phase motor self-cooled
- Phase Failure Sensitivity
- yes
- Product Name
- TeSys Ultra
- Product Specific Application
- basic protection and advanced functions, communication
- Range
- TeSys
- Reset
- manual reset
- Returnability
- No
- Sustainable Packaging
- Yes
- Total Lifecycle Carbon Footprint
- 12 kg CO2 eq.
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Control Circuit Voltage 3 Control Circuit Voltage
- 24 V
- Database Version
- 2023-02
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
- Functional-unit Description
- Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime, In Kwh
- 153.3
- Energy Model - Installation [A5]
- Electricity Mix; Low voltage; 2018; France, FR
- Energy Model - End Of Life [C1-c4]
- Electricity Mix; Low voltage; 2018; France, FR
- Height Nominal
- 66 mm
- [Uc] Control Circuit Voltage
- 24 V AC
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947-6-2
- Nbr. Of Units In Pkg.
- 1
- Take-back
- No
Environment Attributes Main
- Ambient Air Temperature For Storage
- -40-85 °C, -40-85 °C
- Product Compatibility
- power base LUB12, power base LUB32, power base LUB38, power base LUB120, power base LUB320, power base LUB380, reversing contactor breaker LU2B12B, reversing contactor breaker LU2B32B
- Halogene Performance
- Halogen free plastic parts product
- China Rohs Regulation
- X
- Carbon Footprint
- 11.766384378497436
- Circularity Profile
- ENVEOLI2406038EN
- Eu Rohs Directive
- Compliant By Exemption
- Operating Altitude
- 6561.68 ft (2000 m)
- Packaging Without Single Use Plastic
- Yes
- Pep Code
- ENVPEP2406038EN
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
General Attributes
- Product Or Component Type
- advanced control unit
ETIM
- ETIM 8
- EC000617
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$284.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$284.98/ EA
Loading add to cart quantity...