Schneider Electric LUCB32BL TeSys Ultra Control Unit, 3P, 8-32A, 690VAC, 24V DC, Class 10
- MPN: LUCB32BL
- PPN: SCH-LUCB32BL
CAD
$284.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, France, United States |
|---|
| Depth | 60 mm |
|---|
Complementary Attributes
| Control Circuit Voltage Limits | 20...27 V DC 24 V in operation14.5 V DC 24 V drop-out |
|---|
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Device Application | motor control, motor protection |
| Function Available | manual reset, earth fault protection, protection against phase failure and phase imbalance, protection against overload and short-circuit |
| Motor Power Kw | 15 kW 400...440 V AC 50/60 Hz, 15 kW 500 V AC 50/60 Hz18.5 kW 690 V AC 50/60 Hz |
| Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
| Thermal Overload Class | class 10 40-60 Hz -25-70 °C IEC 60947-6-2, class 10 40-60 Hz -25-70 °C UL 508 |
| Utilisation Category | AC-43, AC-41, AC-44 |
| [Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
| Carbon Footprint Of The End-of-life Phase [C1 To C4] | 0.3007436369109041, 0.3 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 1 kg CO2 eq., 1.148045037650806 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Applicability | Finished product |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Reference contains Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant By Exemption |
| Rohs Eur Full Compliance Status | Compliant By Exemption |
| China Rohs Label | 7 |
| Without Single Use Plastic | Yes |
| Tier Id | 2 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Device Short Name | LUCB |
| Fixing Mode | plug-in (front face) |
| Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
| Load Type | 3-phase motor self-cooled |
| Phase Failure Sensitivity | yes |
| Product Name | TeSys Ultra |
| Product Specific Application | basic protection and advanced functions, communication |
| Range | TeSys |
| Reset | manual reset |
| Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
| Shock Resistance | 10 gn power poles open IEC 60068-2-2715 gn power poles closed IEC 60068-2-27 |
| Sustainable Packaging | Yes |
| Total Lifecycle Carbon Footprint | 17 kg CO2 eq. |
| Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-64 gn 5-300 Hz power poles closed IEC 60068-2-6 |
| Pop Directive | No POPs |
| Control Circuit Voltage 3 Control Circuit Voltage | 24 V |
| Database Version | 2023-02 |
| Pcr Version | PCR-4-ed4-EN-2021 09 06 |
| Type Of Verification For The Pep | Independent external review |
| Functional-unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 229.95 |
| Energy Model - Installation [A5] | Electricity Mix; Low voltage; 2018; France, FR |
| Energy Model - End Of Life [C1-c4] | Electricity Mix; Low voltage; 2018; France, FR |
| Height Nominal | 66 mm |
| [Uc] Control Circuit Voltage | 24 V DC |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8537109170 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Fire Resistance | 960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12 |
| Heat Dissipation | 3-3 W control circuit with LUB32, 3-3 W control circuit with LUB38 |
| Operating Time | 70 ms closing with LUB38 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit70 ms closing with LUB32 control circuit |
| Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
| Typical Current Consumption | 80 mA 24 V DC I rms sealed with LUB38, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB3880 mA 24 V DC I rms sealed with LUB32 |
| Certificate Agency | CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine |
| Carbon Footprint Of The Distribution Phase [A4] | 0.06571233329736902, 0.1 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase [A5] | 0 kg CO2 eq., 0.009328981713992428 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 15 kg CO2 eq., 15.363831583386546 |
| Local Publishable Date | 2026-06-27 |
| Stocking Flag | N |
| Device Type | Relay, Control & Measurement - measuring, monitoring device |
| Traceability | Yes |
| Average Life Duration | 15 year(s) |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI2406038EN |
| Reach Full Compliance Status Id | CONTAINS_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 2423 |
| China Rohs In Scope | Yes |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 2 |
| Function Option | Standard |
| Compatibility Code | LUCB |
| Energy Efficiency Optimized | False |
| Immunity To Microbreaks | 3 ms |
| Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
| Network Frequency | 40...60 Hz |
| Product Availability | Stock - Normally stocked in distribution facility |
| Product Or Component Type | advanced control unit |
| Protective Treatment | TH IEC 60068 |
| Range Of Product | TeSys Ultra |
| Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-28 kV 4 on contact IEC 61000-4-2 |
| Returnability | Yes |
| Software Version | v6.1 |
| Thermal Protection Adjustment Range | 8-32 A |
| Tripping Threshold | 14.2 x Ir +/- 20 % |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| R Thermal Protection Adj Range | 8-32 A |
| Pep Code | ENVPEP2406038EN |
| Pep Verification Date | 2024-06-01 |
| Psr Version | PSR-0005-ed3.1-EN-2023 12 08 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | France, FR |
| Energy Model - Use [B6] | Electricity Mix; Low voltage; 2018; France, FR |
| Recyclability Potential In % | 56 |
| Width Nominal | 45 mm |
| [Ue] Rated Operational Voltage | 690 V AC |
| Halogen-free Status | Halogen free plastic parts product |
| Package Weight(Lbs) | 123.000 g |
| Warranty (In Months) | 18 |
Environment Attributes Main
| Ambient Air Temperature For Storage | -40-85 °C, -40-85 °C |
|---|---|
| Product Compatibility | power base LUB32, power base LUB38, power base LUB320, power base LUB380reversing contactor breaker LU2B32BL, reversing contactor breaker LU2B38BL |
| Halogene Performance | Halogen free plastic parts product |
| China Rohs Regulation | X |
| Carbon Footprint | 16.88766157295962 |
| Circularity Profile | ENVEOLI2406038EN |
| Eu Rohs Directive | Compliant By Exemption |
| Operating Altitude | 6561.68 ft (2000 m) |
| Packaging Without Single Use Plastic | Yes |
| Pep Code | ENVPEP2406038EN |
| Pcr Version | PCR-4-ed4-EN-2021 09 06 |
| Type Of Verification For The Pep | Independent external review |
| Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1IP40 front panel outside connection zone IEC 60947-1 |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Ambient Air Temperature For Operation | -25-70 °C-25-70 °C |
| Environmental Disclosure | ENVPEP2406038EN |
| Halogen Content Performance | Halogen free plastic parts product |
| Packaging Made With Recycled Cardboard | Yes |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Pep Verification Date | 2024-06-01 |
| Psr Version | PSR-0005-ed3.1-EN-2023 12 08 |
General Attributes
| Product Or Component Type | advanced control unit |
|---|
| Range Of Product | TeSys Ultra |
|---|
ETIM
| ETIM 8 | EC000617 |
|---|
| ETIM 9 | EC000617 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|

Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$284.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$284.98/ EA
Loading add to cart quantity...