APC SMT3000RMT2U Smart-UPS Line Interactive 3000VA 2U Rackmount 208V Sine Wave, 2x NEMA L6-20R Outlets




APC SMT3000RMT2U Smart-UPS Line Interactive 3000VA 2U Rackmount 208V Sine Wave, 2x NEMA L6-20R Outlets
- MPN: SMT3000RMT2U
- UPC: 731304279556
- PPN: APC-SMT3000RMT2U
Spec sheet
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
CAD$4537.31/ EA
Features
- StruxureWare Data Center Expert compatible — Enables centralized management via StruxureWare Data Center Expert.
- Predictive failure notification. — Provides early-warning fault analysis ensuring proactive component replacement.
- Wide input voltage range — Designed for harsh electrical environments to save battery life.
- LED Indicators — Provide easy-to-read status of the unit and utility power conditions.
- Provides proactive notifications of changing power or unit conditions and provides the user the ability to remotely control PMU functions. — Provides proactive notifications of changing power or unit conditions and provides the user the ability to remotely control PMU functions.
- Boost and Trim Automatic Voltage Regulation (AVR) — Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
- Serial connectivity — Provides management of the UPS via a serial port.
- Reduces utility costs, generates less heat. — Reduces utility costs, generates less heat.
- Green mode — Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Energy meter — Provides actual kilowatt hours of usage for energy conscious users.
- Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. — Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
- Intuitive LCD interface — Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
- Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. — Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- Pure sine wave output on battery — Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Disconnected battery notification — Warns when a battery is not available to provide backup power.
- Sequenced network shutdown and reboot — Customize network shutdown and reboot sequence of connected servers and UPSs.
- Outlet group control — Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
- Adjustable voltage sensitivity — Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Adjustable voltage-transfer points — Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Audible alarms — Provides notification of changing utility power and UPS power conditions
- Automatic restart of loads after UPS shutdown — Automatically starts up the connected equipment upon the return of utility power.
- Automatic self-test — Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Cold-start capable — Provides temporary battery power when the utility power is out.
- Hot-swappable batteries — Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Network manageable — Provides remote power management of the UPS over the network.
- Battery failure notification — Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Safety-agency approved — Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Temperature-compensated battery charging — Prolongs battery life by regulating the charge voltage according to battery temperature.
- USB connectivity — Provides management of the UPS via a USB port (not available on all models).
- User-replaceable batteries — Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Intelligent battery management — Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Frequency and voltage regulation — Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Specifications
- Output Power Capacity
- 3000 VA
- Input Voltage
- 208 V
- Waveform Type
- Sine wave
- Height
- 3.39 in (86 mm)
- Depth
- 26.89 in (683 mm)
- Rack Height
- 2U
- Output Connections
- 2 NEMA L6-20R
- Typical Recharge Time
- 3 h
- Warranty
- 3 years repair or replace (excluding battery), 2 years battery
- Mercury Free
- Yes
- Mount Position
- front
Downloads