This APC Smart-UPS is designed for IT managers or network administrators to maintain business uptime, data transfer and continuity during prolonged power outages. The 2880VA line interactive 2U rack/tower UPS provides pure sine wave power to support critical electronics during power disruptions. The SMX comes with NEMA L5-30P input, 3x NEMA 5-15R, 3x NEMA 5-20R and 1x NEMA L5-30R outlets. The UPS has a preinstalled Network Management Card for UPS network-based monitoring and management. The Smart-UPS comes with PowerChute Network Shutdown that provides graceful shutdown of physical servers, virtual machines, and HCI clusters. This uninterrupted power supply can connect to EcoStruxure IT or third-party centralized management platforms. The SMX UPS has a 3-year warranty, and the built-in lead-acid battery has a 2-year warranty. This is compatible with dedicated user-replaceable battery, and the APC replacement battery cartridge helps restore UPS performance to the original specifications. The Smart-UPS comes with a pair of tower-mounting stabilizing feet and rack-mounting brackets. It comes with APC temperature sensor AP9335T for monitoring temperature. The 3 switchable outlet groups allow more granular management of the power supplied to your devices. The Emergency Power Off feature enables the UPS to remotely shutdown during emergencies.

Features

  • StruxureWare Data Center Expert compatible — Enables centralized management via StruxureWare Data Center Expert.
  • Predictive failure notification. — Provides early-warning fault analysis ensuring proactive component replacement.
  • Wide input voltage range — Designed for harsh electrical environments to save battery life.
  • LED Indicators — Provide easy-to-read status of the unit and utility power conditions.
  • Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
  • Provides proactive notifications of changing power or unit conditions and provides the user the ability to remotely control PMU functions.
  • Boost and Trim Automatic Voltage Regulation (AVR) — Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
  • Serial connectivity — Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
  • Reduces utility costs, generates less heat.
  • Green mode — Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
  • Energy meter — Provides actual kilowatt hours of usage for energy conscious users.
  • Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
  • Intuitive LCD interface — Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
  • UPS recognizes when external battery packs are attached and automatically adjusts runtime.
  • Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non — critical load shedding.-Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
  • Pure sine wave output on battery — Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
  • Disconnected battery notification — Warns when a battery is not available to provide backup power.
  • Load shedding — Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).
  • Sequenced network shutdown and reboot — Customize network shutdown and reboot sequence of connected servers and UPSs.
  • Outlet group control — Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
  • Scalable runtime — Allows additional run time to be quickly added as needed.
  • Adjustable voltage sensitivity — Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Adjustable voltage — transfer points-Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Audible alarms — Provides notification of changing utility power and UPS power conditions
  • Automatic restart of loads after UPS shutdown — Automatically starts up the connected equipment upon the return of utility power.
  • Automatic self — test-Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Cold — start capable-Provides temporary battery power when the utility power is out.
  • Hot — swappable batteries-Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Network manageable — Provides remote power management of the UPS over the network.
  • Power conditioning — Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Battery failure notification — Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Rack/Tower convertible — Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Safety — agency approved-Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Serial connectivity — Provides management of the UPS via a serial port.
  • SmartSlot — Customize UPS capabilities with management cards.
  • Temperature — compensated battery charging-Prolongs battery life by regulating the charge voltage according to battery temperature.
  • USB connectivity — Provides management of the UPS via a USB port (not available on all models).
  • User — replaceable batteries-Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Boost and Trim Automatic Voltage Regulation (AVR) — Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
  • Intelligent battery management — Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Frequency and voltage regulation — Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • 2880VA/2700W line interactive pure sine wave 2U rack/tower UPS (rail kit included)
  • User-selectable low voltage setting of 100V-127V
  • Add up to 10 external battery packs (SMX120RMBP2U)
  • Preinstalled NMC for network-based UPS monitoring & management
  • 1-Year Secure Network Management Card subscription included
  • Automatic Voltage Regulation keeps output voltage within acceptable user selectable levels
  • Ideal for servers, storage, networking & commercial applications
  • Graceful shutdown of physical servers, virtual machines and HCI clusters

Documentation & Downloads

Specifications

Additional

Capacity2880 VA
Input Voltage120 V
Maximum Input Current15 A
Input Connection TypeNEMA L5-30P
Waveform TypeSine wave
Rack Height2U
Weight84.77 lb (38.45 kg)
Battery TypeLead-Acid battery
ColorBlack
Storage Temperature5-113 F (-15-45 C)
Storage Altitude0-50000 ft (0-15240 m)
CertificationsBSMI, CSA, NOM, T V, VCCI Class A
Mercury FreeYes
Power Rating2700 W
Output Voltage120 V
TopologyLine Interactive
Output Connection Type3 NEMA 5-15R, 3 NEMA 5-20R, 1 NEMA L5-30R
Typical Recharge Time3 h
Dimensions (HxWxD)3.35 in x 17.01 in x 26.26 in
Cord Length8 ft (2.44 m)
Surge Energy Rating540 J
Operating Temperature32-104 F (0-40 C)
Operating Altitude0-10000 ft
Relative Humidity0-95 %
RoHSCompliant with Exemptions
Country of OriginPhilippines
Smart-UPS X, 3000VA, 2U Rack/Tower Convertible, 120V, Pure Sine Wave Output