Schneider Electric

Schneider Electric LC1D128BL TeSys Deca Contactor 25A Resistive 4 Pole 24V DC Low Consumption

TeSys Deca Contactor 25A Resistive 4 Pole 24V DC Low Consumption
TeSys Deca Contactor 25A Resistive 4 Pole 24V DC Low Consumption
TeSys Deca Contactor 25A Resistive 4 Pole 24V DC Low Consumption
  • MPN: LC1D128BL
  • PPN: SCH-LC1D128BL
  • UNSPSC: 39121529

Spec sheet

Loading compare button...

In Stock

Company Stock:

00

Lead times may vary. For an accurate estimate please contact us.

Loading dialog...

Looking to buy a large quantity?

To view product inventory

CAD$257.71/ EA

Description

TeSys Deca contactor, 4 poles (2NO+2NC), for non-inductive load applications up to 25A/690V AC-1. They can be used to create motor starters for almost any type of application. It provides a low consumption 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Power contacts have a 25A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 1.16 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Features

  • New modern look & feel of all machines
  • Designed to meet the requirements of industrial and HVAC applications
  • Easier to install and operate with multi-standard screws
  • With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries
  • Digital customer experience for technical documents
  • Maintenance guide via EcoStruxureTM Facility Expect

Specifications

Conformance Attributes

Product Certifications
UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, CSA C22.2 No 60947-4-1

Complementary Attributes

Control Circuit Voltage Limits
0.1...0.3 Uc (-40-70 °C):drop-out DC, 0.8...1.25 Uc (-40-60 °C):operational DC, 1...1.25 Uc (60-70 °C):operational DC
Control Circuit Type
DC low consumption
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
IRMS Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
Non Overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Icw Rated Short Time Withstand Current2
105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Uc Control Circuit Voltage2
24 V, 24 V DC
Ui Rated Insulation Voltage2
power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1
Carbon Footprint Of The End Of Life Phase C1 To C4
1.3003129381185559, 1 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A3
3 kg CO2 eq., 2.6849853456684607
Connections Terminals
screw clamp terminals, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
Icw Rated Short Time Withstand Current5
105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Ue Rated Operational Voltage5
power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
Local Data Status
Publishable
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1102030EN
Reach Full Compliance Status Id
CONTAINS_SVHC
ROHS EUR In Scope
Yes
ROHS EUR Full Compliance Status
Compliant with Exemptions
China ROHS In Scope
No
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Function Option Id
STANDARD
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Compatibility Code
LC1D
Contactor Application
resistive load
Electrical Durability
0.8 Mcycles 25 A AC-1 <= 440 V
Flame Retardance
V1 conforming to UL 94
Inrush Power In W
2.4-2.4 W 20 °C)
Overvoltage Category
III
Pole Contact Composition
2 NO + 2 NC
Power Dissipation Per Pole
1.56 W AC-1
Product Or Component Type
contactor
Range Of Product
TeSys Deca
Signalling Circuit Frequency
25...400 Hz
Time Constant
40 ms
Utilisation Category
AC-1
Ie Rated Operational Current2
25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Medium Desc
IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 2 NO and 2 NC, low consumption 24VDC coil, open style
Product Kit Identifier
N
Rated Thermal Current Ith3
25 A
Database Version
2022-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent external review
Functional Unit Description
Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A.
Energy Model Manufacturing A1 A3 2
Electricity Mix; Production mix; Low voltage; FR
Energy Model Use B6 2
Electricity Mix; Production mix; Low voltage; FR
Global Commercial Status
Commercialised
Uc Control Circuit Voltage5
24 V DC
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Mounting Supportrail, plate
Operating Time77 ±15 % ms closing, 25 ±20 % ms opening
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Ith Conventional Free Air Thermal Current225 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
Ue Rated Operational Voltage2power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
Carbon Footprint Of The Distribution Phase A40.14839419227412126, 0.1 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50 kg CO2 eq., 0.04109287085369836
Carbon Footprint Of The Use Phase B2 B3 B4 B623 kg CO2 eq., 23.17777297297298
Connections Terminals3power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
Ith Conventional Free Air Thermal Current525 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
Ui Rated Insulation Voltage5power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL
Local Publishable Date2025-05-31
ServiceabilityNo
Field Service DivisionPPIBS
Legacy WEEE ScopeIn
EOLI Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
ROHS EUR StatusCompliant with Exemptions
ROHS EUR Full Compliance Status IdCOMPLIANT_WITH_EXEMPTIONS
Green Premium Status For ReportingGreen Premium product
Without Single Use PlasticYes
Return IndicatorN
Function OptionStandard
Coil Technologybuilt-in bidirectional peak limiting diode suppressor
Contact CompatibilityM5
Device Short NameLC1D
Fire Resistance850 °C IEC 60695-2-1
Hold In Power Consumption In W2.4-2.4 W 20 °C
Mechanical Durability30 Mcycles
Package Weight Lbs558.000 g
Poles Description4P
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
ReturnabilityNo
Sustainable PackagingYes
Total Lifecycle Carbon Footprint27 kg CO2 eq.
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Uimp Rated Impulse Withstand Voltage26 kV IEC 60947
Stocking FlagY
Rated Thermal Current Ith225 A
Pep CodeENVPEP110230EN
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29
Data Sourceextrapolated product
Functional Unit Unitunit
Energy Model Installation A5 2Electricity Mix; Production mix; Low voltage; FR
Energy Model End Of Life C1 C4 2Electricity Mix; Production mix; Low voltage; FR
Ie Rated Operational Current525 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Uimp Rated Impulse Withstand Voltage56 kV IEC 60947

Environment Attributes Main

Take Back
Nej, No
Climatic Withstand
IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device
-40-60 °C, -40-60 °C, 60-70 °C with derating
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Circularity Profile
ENVEOLI1102030EN
IP Degree Of Protection
IP20 front face IEC 60529
Packaging Made With Recycled Cardboard
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
China ROHS RegulationProduct out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
EU ROHS DirectiveCompliant By Exemption , Compliant with Exemptions
ROHS Exemption InformationYes
Toxic Heavy Metal FreeYes
Carbon Footprint27.352558319887816
Environmental DisclosureENVPEP110230EN
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Pep CodeENVPEP110230EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent external review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Specifications

Depth
99 mm

Downloads

Similar Products

TeSys Deca Contactor, 4 Pole (2NO+2NC), 25A, 120V AC Coil

Schneider Electric LC1D128G7 TeSys Deca Contactor, 4 Pole (2NO+2NC), 25A, 120V AC Coil

MPN

LC1D128G7

In Stock

Company Stock:

00

CAD$233.34/EA
TeSys Deca 3 Pole Reversing Contactor, 25A, 120V AC Coil, IP20

Schneider Electric LC2D25G7 TeSys Deca 3 Pole Reversing Contactor, 25A, 120V AC Coil, IP20

MPN

LC2D25G7

In Stock

Company Stock:

00

CAD$650.05/EA
TeSys Deca Contactor 3P 25A 24V DC Coil, IP20, 45mm Width

Schneider Electric LC1D25BD TeSys Deca Contactor 3P 25A 24V DC Coil, IP20, 45mm Width

MPN

LC1D25BD

In Stock

Company Stock:

00

CAD$303.40/EA
Reversing Contactor, 3 Poles, 32A, 120V AC, 90mm Width

Schneider Electric LC2D32G7 Reversing Contactor, 3 Poles, 32A, 120V AC, 90mm Width

MPN

LC2D32G7

In Stock

Company Stock:

00

CAD$767.02/EA
TeSys Deca Contactor 3P 25A 24V AC 50/60Hz Coil, Compact Design

Schneider Electric LC1D25B7 TeSys Deca Contactor 3P 25A 24V AC 50/60Hz Coil, Compact Design

MPN

LC1D25B7

In Stock

Company Stock:

00

CAD$259.54/EA
TeSys Deca Contactor 3P 80A 24V DC Coil, Screw Clamp Terminals

Schneider Electric LC1D80BD TeSys Deca Contactor 3P 80A 24V DC Coil, Screw Clamp Terminals

MPN

LC1D80BD

In Stock

Company Stock:

00

CAD$654.92/EA
TeSys Deca 3P Contactor, 18A, 24V DC Coil, Compact Design

Schneider Electric LC1D18BD TeSys Deca 3P Contactor, 18A, 24V DC Coil, Compact Design

MPN

LC1D18BD

In Stock

Company Stock:

00

CAD$266.23/EA
TeSys Deca Contactor 3P 50A 24V DC Coil IP20 55mm Width

Schneider Electric LC1D50ABD TeSys Deca Contactor 3P 50A 24V DC Coil IP20 55mm Width

MPN

LC1D50ABD

In Stock

Company Stock:

00

CAD$503.23/EA
TeSys Deca 3P Contactor, 65A, 24V DC Coil, 55mm Width

Schneider Electric LC1D65ABD TeSys Deca 3P Contactor, 65A, 24V DC Coil, 55mm Width

MPN

LC1D65ABD

In Stock

Company Stock:

00

CAD$579.38/EA
TeSys Deca Contactor, 3P 12A 24V DC Coil, Compact 45mm Width

Schneider Electric LC1D12BD TeSys Deca Contactor, 3P 12A 24V DC Coil, Compact 45mm Width

MPN

LC1D12BD

In Stock

Company Stock:

00

CAD$240.03/EA
TeSys Deca Contactor, 3P, 40A, 24V DC, 55mm Width

Schneider Electric LC1D40ABD TeSys Deca Contactor, 3P, 40A, 24V DC, 55mm Width

MPN

LC1D40ABD

In Stock

Company Stock:

00

CAD$475.82/EA
TeSys Deca 3P Contactor, 40A, 120V AC Coil, IP20, Compact 55mm

Schneider Electric LC1D40AG7 TeSys Deca 3P Contactor, 40A, 120V AC Coil, IP20, Compact 55mm

MPN

LC1D40AG7

In Stock

Company Stock:

00

CAD$390.31/EA

You might also be interested in

Loading carousel layout...

Others Also Viewed

Loading carousel layout...

CAD$257.71/ EA

Loading add to cart quantity...

banner
Need assistance finding the right item?
We can help! Connect with our Sales Team Today!