
Schneider Electric LC1D18BD TeSys Deca 3P Contactor, 18A, 24V DC Coil, Compact Design
- MPN: LC1D18BD
- PPN: SCH-LC1D18BD
CAD
$282.23
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Features
- Specifically designed for the global TeSys D ecosystem, this 18A 3-pole contactor features a standard 45mm width for effortless DIN rail or plate mounting. Using a Schneider Electric OEM contactor ensures seamless mechanical and electrical integration with LR-D thermal overload relays and GV2 manual motor starters, reducing installation time and guaranteeing full system coordination.
- Equipped with a high-efficiency 24V DC coil that consumes only 2.4W, this contactor can be driven directly by the digital outputs of a Programmable Logic Controller (PLC) without the need for an interposing relay. This streamlined control architecture lowers your total hardware costs, reduces cabinet heat dissipation, and simplifies the wiring complexity of your industrial automation panel.
- Rated for 18A (AC-3) and up to 32A (AC-1), this contactor is built to withstand millions of electrical cycles even under the high-stress conditions of 10HP at 480V. The robust silver-alloy contacts resist welding and pitting, providing exceptional reliability for demanding applications such as conveyor systems, pumping stations, and industrial fans.
- This unit comes standard with 1 NO (Normally Open) and 1 NC (Normally Closed) built-in auxiliary contacts, providing immediate status feedback to your control system or safety interlocks. These high-reliability contacts eliminate the need for costly "add-on" blocks for basic signaling, ensuring your control logic always has accurate real-time data on the motor's operational state.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, France, Indonesia, Singapore, United States |
|---|
| Depth | 95 mm |
|---|
Complementary Attributes
| Maximum Horse Power Rating | 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors1 hp at 115 V AC 50/60 Hz for 1 phase motors3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors10 hp at 460/480 V AC 50/60 Hz for 3 phase motors15 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
|---|---|
| Control Circuit Voltage Limits | 0.1...0.25 Uc (-40-70 °C):drop-out DC0.7...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC |
| Maximum Motor Phase Current | 18 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 300 A at 440 V for power circuit conforming to IEC 60947 |
| Control Circuit Type | DC standard |
|---|---|
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1300 A at 440 V for power circuit conforming to IEC 60947 |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Contactor Application | motor control, resistive load |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 7.5 kW at 380/400 V AC 50/60 Hz (AC-3e), 9 kW at 415/440 V AC 50/60 Hz (AC-3e), 10 kW at 500 V AC 50/60 Hz (AC-3e), 10 kW at 660/690 V AC 50/60 Hz (AC-3e), 4 kW at 220/230 V AC 50/60 Hz (AC-3)7.5 kW at 380/400 V AC 50/60 Hz (AC-3)9 kW at 415/440 V AC 50/60 Hz (AC-3)10 kW at 500 V AC 50/60 Hz (AC-3), 10 kW at 660/690 V AC 50/60 Hz (AC-3), 4 kW at 220/230 V AC 50/60 Hz (AC-3e)4 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 2.5 W AC-10.8 W AC-3, 0.8 W AC-3e |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| Certificate Agency | UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1 |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End-of-life Phase [C1 To C4] | 1.3125800413083537, 1 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 3 kg CO2 eq., 2.7103153960992956 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1102030EN |
| Reach Full Compliance Status Id | CONTAINS_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 2538 |
| China Rohs In Scope | No |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Average Impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Durability | 30 Mcycles |
| Operating Time | 63 ±15 % ms closing20 ±20 % ms opening |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v5.9.4 |
| Time Constant | 28 ms |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Inf Motor Phase Current | 18 A |
| Database Version | 2022-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent external review |
| Functional-unit Description | Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A. |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 525.6 |
| Energy Model - Installation [A5] | Electricity Mix; Production mix; Low voltage; FR |
| Energy Model - End Of Life [C1-c4] | Electricity Mix; Production mix; Low voltage; FR |
| Height Nominal | 77 mm |
| [Icw] Rated Short-time Withstand Current | 145 A 40 °C - 10 s for power circuit240 A 40 °C - 1 s for power circuit40 A 40 °C - 10 min for power circuit84 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| [Uc] Control Circuit Voltage | 24 V24 V DC |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536410045 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Electrical Durability | 1.65 Mcycles 18 A AC-3 <= 440 V, 1 Mcycles 32 A AC-1 <= 440 V, 1.65 Mcycles 18 A AC-3e <= 440 V |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms) |
| Mounting Support | plate, rail |
| Tightening Torque | control circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2 |
| Control Circuit Voltage | 24 V |
| [Ie] Rated Operational Current | 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Connections - Terminals | control circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: 2 1.5-6 mm² - cable stiffness: flexible without cable endpower circuit: 1 1-6 mm² - cable stiffness: flexible with cable endpower circuit: 2 1-4 mm² - cable stiffness: flexible with cable endpower circuit: 1 1.5-6 mm² - cable stiffness: solid without cable endpower circuit: 2 1.5-6 mm² - cable stiffness: solid without cable endscrew clamp terminalscontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: flexible without cable end |
| Carbon Footprint Of The Distribution Phase [A4] | 0.1497941374842545, 0.1 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase [A5] | 0 kg CO2 eq., 0.041480539446657784 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 35 kg CO2 eq., 35.11783783783784 |
| Local Publishable Date | 2026-07-07 |
| Stocking Flag | N |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Reference contains Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant By Exemption |
| Rohs Eur Full Compliance Status | Compliant By Exemption |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-150 A gG at <= 690 V coordination type 1 for power circuit35 A gG at <= 690 V coordination type 2 for power circuit |
| Coil Technology | with integral suppression device |
| Contact Compatibility | M4 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Inrush Power In W | 5.4-5.4 W 20 °C) |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Total Lifecycle Carbon Footprint | 39 kg CO2 eq. |
| Connections Terminals | screw clamp terminals |
| Pep Code | ENVPEP110230EN |
| Pep Verification Date | 2025-08-05 |
| Psr Version | PSR-0005-ed2-2016 03 29 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Production mix; Low voltage; FR |
| Energy Model - Use [B6] | Electricity Mix; Production mix; Low voltage; FR |
| Recyclability Potential In % | 75 |
| Width Nominal | 45 mm |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit32 A (at 60 °C) for power circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
| Hold-in Power Consumption In W | 5.4-5.4 W 20 °C |
| Package Weight(Lbs) | 522.500 g |
| Warranty (In Months) | 18 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information. |
|---|---|
| Take Back | No |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1102030EN |
| Eu Rohs Directive | Compliant By Exemption |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Pep Verification Date | 2025-08-05 |
| Psr Version | PSR-0005-ed2-2016 03 29 |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Recycled Metal Content At Cr Level | 0 % |
| Carbon Footprint | 39.3320079521764 |
| Environmental Disclosure | ENVPEP110230EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Pep Code | ENVPEP110230EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent external review |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|




Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$282.23
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$282.23/ EA
Loading add to cart quantity...












