TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides a 230-240V 50/60Hz AC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Documentation & Downloads

Specifications

Key Specifications

Contactor Application
resistive load
Range
TeSys
Device Short Name
LC1K
Product Or Component Typecontactor
Device Applicationcontrol

Complementary

Mechanical Robustness
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
[Ue] Rated Operational Voltage
power circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current
20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Control Circuit Type
AC 50/60 Hz
Rated Breaking Capacity
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Associated Fuse Rating
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
[Uimp] Rated Impulse Withstand Voltage
8 kV
Connections - Terminals
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Utilisation Category
AC-1
Maximum Operating Rate
3600 cyc/h
Electrical Durability
0.16 Mcycles 20 A AC-1 <= 690 V
Poles Description
4P
Operating Time
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Tightening Torque
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Depth
57 mm
[Icw] Rated Short-Time Withstand Current
90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit
[Uc] Control Circuit Voltage230...240 V AC 50/60 Hz
Height58 mm
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.20 Uc (at <50 °C)
Mounting Supportrail || plate
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms Rated Making Capacity110 A AC for power circuit conforming to IEC 60947
Net Weight0.18 kg
Inrush Power In Va30-30 VA (at 20 °C)
Pole Contact Composition4 NO
[Ie] Rated Operational Current20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Signalling Circuit Frequency<= 400 Hz
Mechanical Durability10 Mcycles
Hold-In Power Consumption In Va4.5-4.5 VA (at 20 °C)
Width45 mm
Overvoltage CategoryIII
[Ui] Rated Insulation Voltagepower circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Heat Dissipation1.3-1.3 W

Environment

Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Flame Retardance
V1 UL 94 || requirement 2 NF F 16-101 || requirement 2 NF F 16-102
Protective Treatment
TC IEC 60068 || TC DIN 50016
Operating Altitude
2000 m without derating
StandardsEN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Ambient Air Temperature For Storage-50-80 °C
Ip Degree Of ProtectionIP2X VDE 0106

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1503003EN
Toxic Heavy Metal Free
Yes
Reach Free Of Svhc
Yes
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive
Compliant
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationFree of Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins