TeSys Deca Contactor, 3P 12A 24V DC Coil, Compact 45mm Width
TeSys Deca Contactor, 3P 12A 24V DC Coil, Compact 45mm Width
TeSys Deca Contactor, 3P 12A 24V DC Coil, Compact 45mm Width
TeSys Deca Contactor, 3P 12A 24V DC Coil, Compact 45mm Width
Schneider Electric

Schneider Electric LC1D12BD TeSys Deca Contactor, 3P 12A 24V DC Coil, Compact 45mm Width

  • MPN: LC1D12BD
  • PPN: SCH-LC1D12BD

CAD

$254.46

/ EA

Available to Order

Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3/3e (5.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.07 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Features

  • The Schneider Electric TeSys LC1D12BD is a high-performance 3-pole, 12-Amp IEC contactor designed for reliable motor control. In standard 600V AC industrial environments common in Canada, it is rated for motors up to 10 HP at 600V or 7.5 HP at 480V, making it a staple for small-to-medium pumps, fans, and conveyors.
  • This specific model features a 24V DC coil. Because it is a "BD" series, it includes an integrated bidirectional peak-limiting diode as standard. This protects your sensitive PLC outputs and solid-state controllers from the electrical back-EMF (voltage spikes) that occur when the coil is de-energized, eliminating the need for external surge suppressors.
  • The DC coil in the LC1D12BD is designed for low power consumption, typically drawing only 5.4W of sealed power. This allows for direct control from many PLC I/O cards without the need for an intermediate "interposing" relay, reducing your total component count, saving DIN-rail space, and lowering the heat load inside your control cabinet.
  • Every TeSys D contactor comes factory-equipped with 1NO (Normally Open) and 1NC (Normally Closed) auxiliary contacts. This allows you to simultaneously run your motor while providing a "run status" signal to a PLC and a "fault/ready" signal to a local indicator light or safety interlock loop without purchasing add-on blocks.
  • Engineered for the rigors of heavy industry, the LC1D12BD is rated for millions of mechanical and electrical operations. Its robust construction and silver-alloy contacts are designed to minimize arcing and wear, ensuring long-term reliability and reduced maintenance costs in high-cycle Canadian manufacturing and HVAC applications.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
France, Indonesia, Singapore
Depth95 mm

Complementary Attributes

Irms Rated Making Capacity
250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Control Circuit Type
DC standard
Maximum Motor Phase Current
12 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating3 hp at 230/240 V AC 50/60 Hz for 3 phase motors0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors10 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Control Circuit Voltage Limits0.1...0.25 Uc (-40-70 °C):drop-out DC0.7...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Contactor Application
resistive load, motor control
Insulation Resistance
> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw
5.5 kW at 380/400 V AC 50/60 Hz (AC-3e), 5.5 kW at 415/440 V AC 50/60 Hz (AC-3e), 7.5 kW at 500 V AC 50/60 Hz (AC-3e), 7.5 kW at 660/690 V AC 50/60 Hz (AC-3e), 3 kW at 220/230 V AC 50/60 Hz (AC-3)5.5 kW at 380/400 V AC 50/60 Hz (AC-3), 5.5 kW at 415/440 V AC 50/60 Hz (AC-3)7.5 kW at 500 V AC 50/60 Hz (AC-3), 7.5 kW at 660/690 V AC 50/60 Hz (AC-3), 3 kW at 220/230 V AC 50/60 Hz (AC-3e), 3.7 kW at 400 V AC 50/60 Hz (AC-4)
Power Dissipation Per Pole
0.36 W AC-31.56 W AC-1, 0.36 W AC-3e
Utilisation Category
AC-3, AC-3e, AC-1, AC-4
Certificate Agency
UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
[Ui] Rated Insulation Voltage
signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
Non-overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]
1.3003129381185559, 1 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
3 kg CO2 eq., 2.6849853456684607
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
1
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1102030EN
Reach Full Compliance Status Id
CONTAINS_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
2538
China Rohs In Scope
No
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Compatibility Code
LC1D
Device Short Name
LC1D
Flame Retardance
V1 conforming to UL 94
Mechanical Durability
30 Mcycles
Operating Time
63 ±15 % ms closing20 ±20 % ms opening
Pole Contact Composition
3 NO
Product Or Component Type
contactor
Range Of Product
TeSys Deca
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Version
v5.9.4
Time Constant
28 ms
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Inf Motor Phase Current
12 A
Database Version
2022-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent external review
Functional-unit Description
Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A.
Functional-unit Unit
unit
Energy Model - Manufacturing [A1-a3]
Electricity Mix; Production mix; Low voltage; FR
Energy Model - Use [B6]
Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential In %
75
Width Nominal
45 mm
[Ith] Conventional Free Air Thermal Current
25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In W
5.4-5.4 W 20 °C
Package Weight(Lbs)
520.300 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Electrical Durability2 Mcycles 12 A AC-3 <= 440 V, 0.8 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 12 A AC-3e <= 440 V
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
Mounting Supportplate, rail
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Control Circuit Voltage24 V
[Ie] Rated Operational Current25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Connections - Terminalspower circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endpower circuit: 2 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: solid without cable endscrew clamp terminalspower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.14839419227412126, 0.1 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0 kg CO2 eq., 0.04109287085369836
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]33 kg CO2 eq., 33.186356756756766
Local Publishable Date2026-07-07
Stocking FlagY
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-140 A gG at <= 690 V coordination type 1 for power circuit25 A gG at <= 690 V coordination type 2 for power circuit
Coil Technologywith integral suppression device
Contact CompatibilityM4
Fire Resistance850 °C IEC 60695-2-1
Inrush Power In W5.4-5.4 W 20 °C)
Number Of Poles3P
Overvoltage CategoryIII
Product AvailabilityStock - Normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
ReturnabilityYes
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Total Lifecycle Carbon Footprint37 kg CO2 eq.
Connections Terminalsscrew clamp terminals
Pep CodeENVPEP110230EN
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Installation [A5]Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]Electricity Mix; Production mix; Low voltage; FR
Height Nominal77 mm
[Icw] Rated Short-time Withstand Current105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Uc] Control Circuit Voltage24 V24 V DC
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Take Back
No
Mercury Free
Yes
Circularity Profile
ENVEOLI1102030EN
Eu Rohs Directive
Compliant By Exemption
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Recycled Metal Content At Cr Level0 %
Carbon Footprint37.361142103671604
Environmental DisclosureENVPEP110230EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
Pep CodeENVPEP110230EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent external review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months
Loading video…

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$254.46/ EA

Loading add to cart quantity...

banner

Need assistance?