
Schneider Electric LC2D09G7 Reversing Contactor 3P(3NO), 9A, 120V AC Coil, 90 mm Width
- MPN: LC2D09G7
- PPN: SCH-LC2D09G7
CAD
$482.45
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Features
- This 3-pole reversing contactor features a factory-installed mechanical interlock that physically prevents both contactors from closing at the same time. This critical safety mechanism eliminates the risk of phase-to-phase short circuits when reversing 3-phase motors up to 5 HP at 480V, ensuring smooth, fail-safe operation for conveyor systems, hoists, and automated machinery.
- Equipped with a standard 120V AC 50/60Hz coil (G7 voltage code), this TeSys Deca contactor is optimized for seamless integration with most North American industrial PLC outputs and control transformers. The high-efficiency coil design reduces heat dissipation within your enclosure, extending the lifespan of surrounding sensitive electronic components and lowering overall energy consumption.
- Featuring Schneider Electric s patented EverLink power terminal technology, this unit maintains constant pressure on the copper cables even as the wire "creeps" over time. This prevents loose connections the leading cause of electrical fires and localized overheating significantly reducing the need for periodic re-torqueing and lowering long-term maintenance costs in high-vibration industrial environments.
- Each contactor comes standard with one normally open (NO) and one normally closed (NC) integrated auxiliary contact, providing immediate feedback for status signaling or safety interlocking. These contacts allow your control system to verify motor direction and state without the need for expensive add-on blocks, simplifying your panel wiring and reducing the total footprint on the DIN rail.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, France, Indonesia, Mexico, Singapore, United States, ZZ |
|---|
| Depth | 86 mm |
|---|
Complementary Attributes
| Control Circuit Type | AC 50/60 Hz, AC 50/60 Hz |
|---|---|
| Irms Rated Making Capacity | 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Maximum Motor Phase Current | 9 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| Control Circuit Voltage Limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
|---|---|
| Maximum Horse Power Rating | 2 hp at 230/240 V AC 60 Hz for 3 phase motors0.5 hp at 115 V AC 60 Hz for 1 phase motors1 hp at 230/240 V AC 60 Hz for 1 phase motors, 2 hp at 200/208 V AC 60 Hz for 3 phase motors5 hp at 460/480 V AC 60 Hz for 3 phase motors7.5 hp at 575/600 V AC 60 Hz for 3 phase motors |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 25 A gG at <= 690 V coordination type 1 for power circuit20 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
| Electrical Durability | 0.6 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 2.2 kW at 220...230 V AC 50 Hz4 kW at 380...400 V AC 50 Hz, 4 kW at 415...440 V AC 50 Hz5.5 kW at 500 V AC 50 Hz, 5.5 kW at 660...690 V AC 50 Hz |
| Product Name | TeSys D, TeSys Deca |
| Range Of Product | TeSys D, TeSys Deca |
| Utilisation Category | AC-1, AC-3 |
| Certificate Agency | DNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1 |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The Installation Phase [A5] | 0.1 kg CO2 eq., 0.11221252432803858 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 42 kg CO2 eq., 41.75906334591097 |
| Local Publishable Date | 2026-06-27 |
| Stocking Flag | N |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Coil Technology | without built-in suppressor module |
| Contact Compatibility | M2 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Heat Dissipation | 2-3 W 50/60 Hz |
| Mechanical Durability | 15 Mcycles |
| Operating Time | 12...22 ms closing4...19 ms opening |
| Pole Contact Composition | 3 NO |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | TH IEC 60068-2-30 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.2.4 |
| Total Lifecycle Carbon Footprint | 45 kg CO2 eq. |
| Inf Motor Phase Current | 9 A |
| Database Version | 2024-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Functional-unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 464.28 |
| Energy Model - Installation [A5] | No energy used |
| Energy Model - End Of Life [C1-c4] | Global, European and French datasets are used. |
| Height Nominal | 77 mm |
| [Icw] Rated Short-time Withstand Current | 30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit25 A (at 60 °C) for power circuit |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Rated Thermal Current (Ith) | 25 A |
| Package Weight(Lbs) | 798.000 g |
| Warranty (In Months) | 18 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Contactor Application | resistive load, motor control |
| Inrush Power In Va | 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Mechanical Robustness | vibrations contactor open2 Gn, 5...300 Hzvibrations contactor closed4 Gn, 5...300 Hzshocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms |
| Mounting Support | plate, rail |
| Range | TeSys, TeSys Deca |
| Tightening Torque | control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2 |
| Control Circuit Voltage | 120 V |
| [Uc] Control Circuit Voltage | 120 V, 120 V AC 50/60 Hz |
| Connections - Terminals | power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable endpower circuit screw clamp terminals 2 1-4 mm²solidcontrol circuit screw clamp terminals 2 1-4 mm²flexible without cable endcontrol circuit screw clamp terminals 1 1-4 mm²flexible with cable endcontrol circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end |
| Carbon Footprint Of The Distribution Phase [A4] | 0.31842114248346615, 0.3 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 3 kg CO2 eq., 2.8490333533820227 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1501004 |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 2538 |
| China Rohs In Scope | No |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Compatibility Code | LC2D |
| Device Short Name | LC2D |
| Flame Retardance | V1 conforming to UL 94 |
| Interlocking Type | mechanical |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Power Dissipation Per Pole | 0.2 W AC-31.56 W AC-1 |
| Product Or Component Type | reversing contactor |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Pep Code | ENVPEP1501004EN |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Low voltage; 2020; France, FR |
| Energy Model - Use [B6] | Electricity Mix; Low voltage; 2020; France, FR |
| Recyclability Potential In % | 66 |
| Width Nominal | 90 mm |
| [Ie] Rated Operational Current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
| Hold-in Power Consumption In Va | 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536490065 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope) |
|---|---|
| Climatic Withstand | IACS E10, IEC 60947-1 Annex Q category D |
| Reach Free Shvc | Yes |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 45.038730366104495 |
| Circularity Profile | ENVEOLI1501004 |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Ambient Air Temperature For Storage | -60-80 °C, -60-80 °C |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Ambient Air Temperature For Operation | -40-60 °C-40-60 °C60-70 °C with derating |
| Environmental Disclosure | ENVPEP1501004EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Reach Free Of Svhc | Yes |
| Pep Code | ENVPEP1501004EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
General Attributes
| Range Of Product | TeSys D, TeSys Deca |
|---|
| Product Or Component Type | reversing contactor |
|---|
ETIM
| ETIM 8 | EC000010 |
|---|
| ETIM 9 | EC000010 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|
Overview Attributes
| Device Presentation | preassembled with reversing power busbar |
|---|

Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$482.45
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$482.45/ EA
Loading add to cart quantity...











