Schneider Electric

Schneider Electric LC2D09G7V TeSys D Reversing Contactor, 9A, 120V AC Coil, 3P, Screw Clamp Terminals

  • MPN: LC2D09G7V
  • PPN: SCH-LC2D09G7V

CAD

$482.45

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys Deca contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A reversing inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 1HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Pressure wire connectors are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 3.54 inches wide and 3.39 inches deep. It weighs 1.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Documentation & Downloads

Specifications

Key Specifications

Country of OriginFrance, United States
Depth86 mm

Complementary Attributes

Control Circuit TypeAC 50/60 Hz, AC 50/60 Hz
Irms Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Motor Phase Current9 A
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity250 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Maximum Horse Power Rating2 hp at 230/240 V AC 60 Hz for 3 phase motors0.5 hp at 115 V AC 60 Hz for 1 phase motors1 hp at 230/240 V AC 60 Hz for 1 phase motors, 2 hp at 200/208 V AC 60 Hz for 3 phase motors5 hp at 460/480 V AC 60 Hz for 3 phase motors7.5 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Operating Rate3600 cyc/h 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Associated Fuse Rating25 A gG at <= 690 V coordination type 1 for power circuit20 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1
Electrical Durability0.6 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw2.2 kW at 220...230 V AC 50 Hz4 kW at 380...400 V AC 50 Hz, 4 kW at 415...440 V AC 50 Hz5.5 kW at 500 V AC 50 Hz, 5.5 kW at 660...690 V AC 50 Hz
Product NameTeSys D, TeSys Deca
Range Of ProductTeSys D, TeSys Deca
Utilisation CategoryAC-3, AC-1
Certificate AgencyDNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA
[Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.11221252432803858
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]42 kg CO2 eq., 41.75906334591097
Local Publishable Date2026-06-27
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologywithout built-in suppressor module
Contact CompatibilityM2
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation2-3 W 50/60 Hz
Mechanical Durability15 Mcycles
Operating Time12...22 ms closing4...19 ms opening
Pole Contact Composition3 NO
Product AvailabilityStock - Normally stocked in distribution facility
Protective TreatmentTH IEC 60068-2-30
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.2.4
Total Lifecycle Carbon Footprint45 kg CO2 eq.
Inf Motor Phase Current9 A
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh464.28
Energy Model - Installation [A5]No energy used
Energy Model - End Of Life [C1-c4]Global, European and French datasets are used.
Height Nominal77 mm
[Icw] Rated Short-time Withstand Current30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit25 A (at 60 °C) for power circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Rated Thermal Current (Ith)25 A
Package Weight(Lbs)730.0 g
Warranty (In Months)18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationresistive load, motor control
Inrush Power In Va70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustnessvibrations contactor open2 Gn, 5...300 Hzvibrations contactor closed4 Gn, 5...300 Hzshocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
Mounting Supportrail, plate
RangeTeSys, TeSys Deca
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2
Control Circuit Voltage120 V
[Uc] Control Circuit Voltage120 V, 120 V AC 50/60 Hz
Connections - Terminalspower circuit screw clamp terminals 2 1-2.5 mm²flexible with cable endpower circuit screw clamp terminals 2 1-4 mm²solidcontrol circuit screw clamp terminals 2 1-4 mm²flexible without cable endcontrol circuit screw clamp terminals 1 1-4 mm²flexible with cable endcontrol circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.31842114248346615, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]3 kg CO2 eq., 2.8490333533820227
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1501004
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2538
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Compatibility CodeLC2D
Device Short NameLC2D
Flame RetardanceV1 conforming to UL 94
Interlocking Typeelectrical and mechanical
Number Of Poles3P
Overvoltage CategoryIII
Power Dissipation Per Pole0.2 W AC-31.56 W AC-1
Product Or Component Typereversing contactor
ReturnabilityYes
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep CodeENVPEP1501004EN
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %66
Width Nominal90 mm
[Ie] Rated Operational Current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In Va7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Climatic WithstandIACS E10, IEC 60947-1 Annex Q category D
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint45.038730366104495
Circularity ProfileENVEOLI1501004
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Ambient Air Temperature For Storage-60-80 °C, -60-80 °C
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Temperature For Operation-40-60 °C-40-60 °C60-70 °C with derating
Environmental DisclosureENVPEP1501004EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1501004EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Range Of ProductTeSys D, TeSys Deca
Product Or Component Typereversing contactor

ETIM

ETIM 8EC000010
ETIM 9EC000010

Contractual Warranty Attributes

Warranty Period18 months
Warranty18 months

Overview Attributes

Device Presentationpreassembled with reversing power busbar
TeSys D Reversing Contactor, 9A, 120V AC Coil, 3P, Screw Clamp Terminals

Similar Products

Loading carousel layout...

CAD$482.45/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!