Schneider Electric

Schneider Electric LC2D18G7 TeSys Deca Reversing Contactor 3P 18A 120V AC Coil 690V

  • MPN: LC2D18G7
  • PPN: SCH-LC2D18G7

CAD

$602.57

/ EA

Available to Order

Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 18A/690V AC-3 (7.5kW@400V). They can be used to create motor starters for almost any type of application. It provides 120V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Documentation & Downloads

Specifications

Key Specifications

Country of OriginFrance, Indonesia, Singapore, United States
Depth86 mm

Complementary Attributes

Control Circuit TypeAC 50/60 Hz, AC 50/60 Hz
Maximum Horse Power Rating5 hp at 230/240 V AC 60 Hz for 3 phase motors1 hp at 115 V AC 60 Hz for 1 phase motors3 hp at 230/240 V AC 60 Hz for 1 phase motors, 5 hp at 200/208 V AC 60 Hz for 3 phase motors10 hp at 460/480 V AC 60 Hz for 3 phase motors15 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Motor Phase Current18 A
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity300 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1300 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate3600 cyc/h 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Contactor Applicationresistive load, motor control
Inrush Power In Va70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustnessvibrations contactor open2 Gn, 5...300 Hzvibrations contactor closed4 Gn, 5...300 Hzshocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
Mounting Supportplate, rail
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2
Control Circuit Voltage120 V
[Uc] Control Circuit Voltage120 V, 120 V AC 50/60 Hz
Connections - Terminalscontrol circuit screw clamp terminals 2 1-2.5 mm²flexible with cable endcontrol circuit screw clamp terminals 2 1-4 mm²solidpower circuit screw clamp terminals 2 1.5-6 mm²flexible without cable endpower circuit screw clamp terminals 1 1-6 mm²flexible with cable endpower circuit screw clamp terminals 2 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1.5-6 mm²solid, power circuit screw clamp terminals 2 1.5-6 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solidpower circuit screw clamp terminals 1 1.5-6 mm²flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.32769104473917116, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]3 kg CO2 eq., 2.931974644601296
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1501004
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2538
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-150 A gG at <= 690 V coordination type 1 for power circuit35 A gG at <= 690 V coordination type 2 for power circuit
Coil Technologywithout built-in suppressor module
Contact CompatibilityM2
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation2-3 W 50/60 Hz
Mechanical Durability15 Mcycles
Operating Time12...22 ms closing4...19 ms opening
Pole Contact Composition3 NO
Product AvailabilityStock - Normally stocked in distribution facility
Product Or Component Typereversing contactor
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.2.4
Total Lifecycle Carbon Footprint52 kg CO2 eq.
Inf Motor Phase Current18 A
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh543.12
Energy Model - Installation [A5]No energy used
Energy Model - End Of Life [C1-c4]Global, European and French datasets are used.
Height Nominal77 mm
[Icw] Rated Short-time Withstand Current40 A 40 °C - 10 min for power circuit84 A 40 °C - 1 min for power circuit145 A 40 °C - 10 s for power circuit240 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit32 A (at 60 °C) for power circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Rated Thermal Current (Ith)32 A
Package Weight(Lbs)812.000 g
Warranty (In Months)18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Electrical Durability1.65 Mcycles 18 A AC-3 <= 440 V, 1 Mcycles 32 A AC-1 <= 440 V
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw4 kW at 220...230 V AC 50 Hz7.5 kW at 380...400 V AC 50 Hz9 kW at 415...440 V AC 50 Hz10 kW at 500 V AC 50 Hz, 10 kW at 660...690 V AC 50 Hz
RangeTeSys, TeSys Deca
Utilisation CategoryAC-3, AC-1
Certificate AgencyDNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA
[Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.11547926448314888
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]49 kg CO2 eq., 48.85022504616
Local Publishable Date2026-06-27
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Average Impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
Compatibility CodeLC2D
Device Short NameLC2D
Flame RetardanceV1 conforming to UL 94
Interlocking Typemechanical
Number Of Poles3P
Overvoltage CategoryIII
Power Dissipation Per Pole0.8 W AC-32.5 W AC-1
Product NameTeSys Deca
Protective TreatmentTH IEC 60068-2-30
ReturnabilityYes
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep CodeENVPEP1501004EN
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %66
Width Nominal90 mm
[Ie] Rated Operational Current18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In Va7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Climatic WithstandIACS E10, IEC 60947-1 Annex Q category D
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint52.22536999998361
Circularity ProfileENVEOLI1501004
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Ambient Air Temperature For Storage-60-80 °C, -60-80 °C
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Temperature For Operation-40-60 °C-40-60 °C60-70 °C with derating
Environmental DisclosureENVPEP1501004EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1501004EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Typereversing contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8EC000010
ETIM 9EC000010

Contractual Warranty Attributes

Warranty Period18 months
Warranty18 months

Overview Attributes

Device Presentationpreassembled with reversing power busbar
TeSys Deca Reversing Contactor 3P 18A 120V AC Coil 690V

Similar Products

Loading carousel layout...

CAD$602.57/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!