Schneider Electric M8650A0C0H6E1C4A PowerLogic ION8650 Meter, 128MB, 57-277 VAC, Ethernet, 7 kg
- MPN: M8650A0C0H6E1C4A
- PPN: SCH-M8650A0C0H6E1C4A
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Description
Documentation & Downloads
Specifications
Key Specifications
| Product Or Component Type | revenue and power quality meter |
|---|---|
| Device Short Name | ION8650A |
| Range | PowerLogic |
|---|
Complementary
| Network Frequency | 60 Hz |
|---|---|
| Power Quality Analysis | IEC 61000-4-15 flicker || magnitude harmonic up to the 50th || transient capture || EN 50160 ed. 4 compliance report || harmonic distortion || voltage sag and swell detection || waveform capture || programmablity (logic and math functions) || up to the 63rd harmonic || IEC 61000-4-30 class A power quality measurement |
| Sampling Rate | 1024 samples/cycle |
| Number Of Outputs | 2 pulse || 4 form C relay output || 1 form A triac output |
| Communication Port Protocol | DNP3 300...115200 bauds || ION 300...115200 bauds || Ansi C12.18 <= 19200 bauds || IEC 61850 ed. 2 10/100 Mbit/s || TCP/IP 10/100 Mbit/s || DLMS 300...115200 bauds || Modbus 57600 bauds || DNP3 10/100 Mbit/s || ION 10/100 Mbit/s || Modbus RTU, master/slave 300...115200 bauds || Modbus TCP, master/slave 10/100 Mbit/s || EtherGate |
| Number Of Inputs | 1 digital 0.001...100 mA 30 V DC |
| Measurement Current | 0.001-24 A |
| Time Synchronisation Protocol | IRIG-B || GPS: Truetime/Datum |
| Ethernet Service | SNMP-Traps and SYSLOG || enable/disable serial ports || enable/disable Ethernet protocols |
| Compatibility Code | ION8650A |
| [Us] Rated Supply Voltage | 120...277 V AC 47...63 Hz || 65...120 V AC 47...63 Hz || 80...160 V DC |
| Outlet Standard | American |
| Web Services | port addressing user designed || robust security logs || alarm notification by e-mail || web server |
| Transmission Rate | 300...115200 bauds || 10/100 Mbit/s || <= 19200 bauds || 57600 bauds |
| Accuracy Class | class 0.2S energy IEC 62053-23 || class 0.2 energy ANSI C12.20 || class 0.2S energy IEC 62053-22 |
| Communication Port Support | RJ45 ETHERNET || SUB-D 9 RS485/RS232 || terminal block RS485 || infrared |
|---|---|
| Measurement Voltage | 57-277 V AC phase to neutral || 100-480 V AC phase to phase |
| Memory Capacity | 128 MB |
| Type Of Measurement | current || voltage || frequency || apparent power total || power factor total || apparent power per phase || power factor per phase || active power total || active power per phase || reactive power total || reactive power per phase |
| Power Consumption In Va | 24 VA |
| Tamperproof Of Settings | RMICAN protected || protected by sealable cover |
| Form Designation | 9S 3-element 4 || 36S 2 1/2-element 4 || 29S 2 1/2-element 4 |
| Measurement Accuracy | current 0.1 % || voltage 0.1 % || power 0.1 % || power factor 0.1 % || frequency 0.001 Hz || energy 0.1 % |
| Poles Description | 1P + N || 3P + N || 3P |
| Data Recording | data logs || alarms || historical logs || transient logs || event logs || time stamping || GPS synchronisation || revenue logs || harmonics logs || sag and swell logs |
| [In] Rated Current | 2 A || 1 A || 5 A |
| Analogue Input Type | current 0.01...20 A (impedance 0.05 Ohm) |
| Display Type | FSTN transflective LCD |
| Device Application | instrument transformer correction || energy pulsing and totalisation || demand and power factor control || co-generation and IPP monitoring || equipment monitoring and control || load curtailment || tariff metering |
| Maximum Power Consumption In Va | 33 VA |
Offer Sustainability
| Environmental Disclosure | ENVPEP110723EN |
|---|---|
| Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Circularity Profile | ENVEOLI110703EN |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
|---|---|
| China Rohs Regulation | X |
| Eu Rohs Directive | Compliant with Exemptions |
Environment
| Ambient Air Temperature For Operation | -40-85 °C |
|---|---|
| Standards | ANSI C12.1 || IEC 62052-11 |
| Net Weight | 7 kg |
| Pollution Degree | 2 |
| Ambient Air Temperature For Storage | -40-85 °C |
| Mounting Support | enclosure door |
| Width | 178 mm |
| Depth | 237 mm |
| Height | 178 mm |
|---|---|
| Electromagnetic Compatibility | electrostatic discharge immunity test conforming to IEC 61000-4-2 || conducted RF disturbances conforming to IEC 61000-4-6 || immunity to impulse waves conforming to IEC 61000-4-12 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || susceptibility to electromagnetic fields conforming to IEC 61000-4-3 || 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 || conducted and radiated emissions B conforming to CISPR 22 |
| Type Of Installation | indoor installation |
| Mounting Mode | socket-mounted |
| Relative Humidity | 5-95 % |
| Ip Degree Of Protection | front face IP65 || back IP51 |
| Overvoltage Category | III |
| Operating Altitude | 0...3000 m |