Tripp Lite SMART1500SLT SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, Network Card Options, USB, DB9, 8 Outlets



Tripp Lite SMART1500SLT SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, Network Card Options, USB, DB9, 8 Outlets
- MPN: SMART1500SLT
- UPC: 037332119896
- PPN: TRP-SMART1500SLT
Spec sheet
Available to Order
Company Stock:
0
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
CAD$1565.20/ EA
Description
Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise. Ideal solution for VoIP systems, point-of-sale applications and network closets.
Features
- Corrects under- and overvoltages from 95V to 145V
- 8 NEMA 5-15R outlets
- Front-panel LEDs indicate load, power and battery statuses
- Monitoring of power conditions via PowerAlert®
- 20 min. runtime at half load; 8 min. at full load
- 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
- $250,000 Ultimate Lifetime Insurance
Specifications
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 690
- UPS Dataline Suppression
- 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
UPS AC Suppression Response TimeInstantaneous
EMI / RFI AC Noise SuppressionYes
Battery
- Full Load Runtime (min.)
- 8 min. (900w)
- DC System Voltage (VDC)
- 36
- Internal UPS Replacement Battery Cartridge
- RBC36-SLT
- Battery Replacement Description
- Hot-swappable, user replaceable batteries
Half Load Runtime (min.)20 min. (450w)
Battery Recharge Rate (Included Batteries)Less than 8 hours from 10% to 90% (typical, full load discharge)
Battery AccessBattery access door
Expandable RuntimeNo
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
Physical
- Cooling Method
- Fan
- Primary UPS Depth (mm)
- 335
- Primary UPS Width (mm)
- 173
- Shipping Weight (lbs.)
- 49.50
- UPS Power Module Dimensions (hwd, in.)
- 10.2 x 6.8 x 13.2
- UPS Power Module Weight (lbs.)
- 45
Primary Form FactorTower
Primary UPS Height (mm)259
Shipping Dimensions (hwd / in.)13.90 x 9.70 x 17.60
UPS Housing MaterialSteel
UPS Power Module Weight (kg)20.41
User Interface, Alerts & Controls
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
- Audible Alarm
- Audible alarm indicates power failure and overload conditions
- Site Wiring Fault Indication
- Rear panel site wiring fault LED
Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch
LED IndicatorsStatus LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level
Voltage Regulation
- Voltage Regulation Description
- Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 95 to 145 (120v), 87 to 133 (110v), 83 to 121 (100v)
- Undervoltage Correction
- Voltage boost of 14% applies when input is 95 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v)
Overvoltage CorrectionVoltage reduction of 12% applies when input is 127 to 145 (120v), 116 to 133 (110v), 111 to 121 (100v)
Input
- Rated input current (Maximum Load)
- 10.1A (100V), 9.3A (110V), 8.6A (120V)
- UPS Input Connection Type
- 5-15P
- Recommended Electrical Service
- 15A 120V
Nominal Input Voltage(s) Supported100V AC; 110V AC; 120V AC
UPS Input Cord Length (ft.)6
Input PhaseSingle-Phase
Output
- Output Volt Amp Capacity (VA)
- 1500
- Output Watt Capacity (Watts)
- 900
- Frequency Compatibility
- 50 / 60 Hz
- Output Voltage Regulation (Line Mode)
- -13%, + 15%
- Output AC Waveform (AC Mode)
- Sine wave
- Nominal Output Voltage(s) Supported
- 100V; 110V; 120V
- Individually Controllable Load Banks
- No
Output kVA Capacity (kVA)1.5
Nominal Voltage Details120V default (voltage selection via back panel switches)
Frequency Compatibility DetailsAutomatic frequency selection
Output Voltage Regulation (Battery Mode)+/- 5%
Output AC Waveform (Battery Mode)Pure Sine wave
Output Receptacles(8) 5-15R
Communications
- Network Management Cards
- SNMPWEBCARD ; WEBCARDLX ; RELAYIOCARD
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions
Communications CableUSB and DB9 cabling included
Communications InterfaceUSB; DB9 Serial; Slot for SNMP/Web interface
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Relative Humidity
- 0 to 95%, non-condensing
- Battery Mode BTU / Hr. (Full Load)
- 500
- Audible Noise
- Audible Noise < 50 dBA at Front Side 1 Meter
Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
AC Mode BTU / Hr. (Full Load)148
AC Mode Efficiency Rating (100% Load)95%
Overview
- UPC Code
- 037332119896
UPS TypeLine-Interactive
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- Green Energy-Saving Features
- Greater than 95% efficiency - GREEN UPS
High Availability UPS FeaturesHot swappable batteries
Warranty
- Product Warranty Period (Worldwide)
- 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
Connected Equipment Insurance (U.S., Canada & Puerto Rico)$250,000 Ultimate Lifetime Insurance
Line / Battery Transfer
- Transfer Time
- 4-6 milliseconds
- High Voltage Transfer to Battery Power (Setpoint)
- 145V (120V), 133V (110V), 121V (100V)
Low Voltage Transfer to Battery Power (Setpoint)95V (120V), 87V (110V), 83V (100V)