Key Specifications
- Country of Origin
- Brazil, France
Complementary Attributes
- Control Circuit Voltage Limits
- 29 V DC 48...72 V drop-out38.5...72 V AC 48 V in operation, 38.5...93 V DC 48...72 V in operation, 29 V AC 48 V drop-out
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Device Application
- motor control, motor protection
- Function Available
- earth fault protection, protection against overload and short-circuit, manual reset, protection against phase failure and phase imbalance
- Motor Power Kw
- 7.5 kW 400...440 V AC 50/60 Hz, 9 kW 500 V AC 50/60 Hz, 15 kW 690 V AC 50/60 Hz
- Resistance To Electrostatic Discharge
- 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
- Safe Separation Of Circuit
- 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Thermal Overload Class
- class 10 40-60 Hz -25-70 °C IEC 60947-6-2, class 10 40-60 Hz -25-70 °C UL 508
- Utilisation Category
- AC-41, AC-44, AC-43
- Certificate Agency
- CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
- [Ui] Rated Insulation Voltage
- 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
- Carbon Footprint Of The Distribution Phase [A4]
- 0.06731507313389022, 0.1 kg CO2 eq.
- Carbon Footprint Of The Installation Phase [A5]
- 0 kg CO2 eq., 0.009556517853358096
- Carbon Footprint Of The Use Phase [B2, B3, B4, B6]
- 21 kg CO2 eq., 21.07039760007298
- Local Publishable Date
- 2025-08-13
- Stocking Flag
- Y
- Device Type
- Relay, Control & Measurement - measuring, monitoring device
- Traceability
- Yes
- Average Life Duration
- 15 year(s)
- Weee Scope
- In
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI2406038EN
- Reach Full Compliance Status Id
- CONTAINS_SVHC
- Rohs Eur In Scope
- Yes
- Rohs Eur Conformity Date
- 1927
- China Rohs In Scope
- Yes
- With Recycled Cardboard
- Yes
- Product Contributes To Saved And Avoided Emissions
- No
- Tier
- 2
- Function Option
- Standard
- Compatibility Code
- LUCA
- Energy Efficiency Optimized
- False
- Immunity To Microbreaks
- 3 ms
- Immunity To Voltage Dips
- 70 % / 500 ms IEC 61000-4-11
- Network Frequency
- 40...60 Hz
- Product Availability
- Non-Stock - Not normally stocked in distribution facility
- Product Or Component Type
- standard control unit
- Protective Treatment
- TH IEC 60068
- Range Of Product
- TeSys Ultra
- Returnability
- No
- Sustainable Packaging
- Yes
- Total Lifecycle Carbon Footprint
- 23 kg CO2 eq.
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Control Circuit Voltage 3 Control Circuit Voltage
- 48...72 V
- Load Type 6 Load Type
- 3-phase motor
- Database Version
- 2023-02
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
- Functional-unit Description
- Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime, In Kwh
- 315.36
- Energy Model - Installation [A5]
- Electricity Mix; Low voltage; 2018; France, FR
- Energy Model - End Of Life [C1-c4]
- Electricity Mix; Low voltage; 2018; France, FR
- Height Nominal
- 66 mm
- [Ue] Rated Operational Voltage
- 690 V AC
- Halogen-free Status
- Halogen free plastic parts product
- Package Weight(Lbs)
- 126.000 g
- Warranty (In Months)
- 18
Environment Attributes Main
- Ambient Air Temperature For Storage
- -40-85 °C, -40-85 °C
- Product Compatibility
- power base LUB32, power base LUB38, power base LUB320, power base LUB380, reversing contactor breaker LU2B32ES
- Halogene Performance
- Halogen free plastic parts product
- China Rohs Regulation
- X
- Carbon Footprint
- 22.631394174757588
- Circularity Profile
- ENVEOLI2406038EN
- Eu Rohs Directive
- Compliant By Exemption
- Operating Altitude
- 6561.68 ft (2000 m)
- Packaging Without Single Use Plastic
- Yes
- Pep Code
- ENVPEP2406038EN
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
General Attributes
- Product Or Component Type
- standard control unit
ETIM
- ETIM 8
- EC000617
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$227.22
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$227.22/ EA
Loading add to cart quantity...