Key Specifications
- Country of Origin
- Brazil, France, Indonesia
Complementary Attributes
- Control Circuit Voltage Limits
- operational: 0.8...1.15 Uc (at <50 °C), drop-out: >= 0.20 Uc (at <50 °C)
- Rated Breaking Capacity
- 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
- Maximum Motor Phase Current
- 9 A
- Minimum Switching Current
- 5 mA for signalling circuit
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Associated Fuse Rating
- 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
- Electrical Durability
- 1.3 Mcycles 9 A AC-3 <= 440 V, 1.3 Mcycles 9 A AC-3e <= 440 V, 0.16 Mcycles 20 A AC-1 <= 690 V, 0.02 Mcycles 54 A AC-4 <= 440 V
- Insulation Resistance
- > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Motor Power Kw
- 4 kW 380...415 V AC 50/60 Hz AC-3e, 4 kW 440/690 V AC 50/60 Hz AC-3e, 4 kW 380...415 V AC 50/60 Hz AC-4, 4 kW 440/690 V AC 50/60 Hz AC-42.2 kW 220...230 V AC 50/60 Hz AC-3, 4 kW 380...415 V AC 50/60 Hz AC-3, 4 kW 440/690 V AC 50/60 Hz AC-3, 2.2 kW 220...230 V AC 50/60 Hz AC-3e, 2.2 kW 220...230 V AC 50/60 Hz AC-4
- Protective Treatment
- TC IEC 60068, TC DIN 50016
- Signalling Circuit Frequency
- <= 400 Hz, <= 400 Hz
- Certificate Agency
- CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
- [Ie] Rated Operational Current
- 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
- [Uc] Control Circuit Voltage
- 48 V AC 50/60 Hz, 48 V
- Connections - Terminals
- screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 2 0.34-1.5 mm²flexible with cable end, screw clamp terminals, screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid
- Carbon Footprint Of The End-of-life Phase [C1 To C4]
- 0.25761189519253946, 0.3 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase [A1 To A3]
- 0.9 kg CO2 eq., 0.9191500378989131
- Local Data Status
- Publishable
- Return Indicator
- Y
- Stock Policy
- 2
- Serviceability
- No
- Field Service Division
- PPIBS
- Weee Scope
- In
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI1503003
- Reach Full Compliance Status Id
- NOT_CONTAINING_SVHC
- Rohs Eur In Scope
- Yes
- Rohs Eur Conformity Date
- 2448
- China Rohs Label
- 1
- Without Single Use Plastic
- Yes
- Tier Id
- 1
- Function Option Id
- STANDARD
- Product Kit Identifier
- N
- Coil Technology
- without built-in suppressor module
- Device Application
- control
- Heat Dissipation
- 1.3-1.3 W
- Mechanical Durability
- 10 Mcycles
- Number Of Poles
- 3P
- Pole Contact Composition
- 3 NO
- Product Or Component Type
- contactor
- Range Of Product
- TeSys K
- Software Version
- v6.2.4
- Total Lifecycle Carbon Footprint
- 58 kg CO2 eq.
- Pep Code
- ENVPEP1503003EN
- Pep Verification Date
- 2026-03-23
- Psr Version
- PSR-0005-ed3-2023 06 06
- Data Source
- extrapolated product
- Functional-unit Quantity
- 1
- Reference Lifetime, In Y
- 20
- Energy Model - Installation [A5]
- No energy used
- Energy Model - End Of Life [C1-c4]
- Global, European and French datasets are used.
- Height Nominal
- 58 mm
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Nbr. Of Units In Pkg.
- 1
- Take-back
- No
Environment Attributes Main
- Take Back
- No
- Recycled Metal Content At Cr Level
- 0 %
- Toxic Heavy Metal Free
- Yes
- Carbon Footprint
- 58.208309019086165
- Environmental Disclosure
- ENVPEP1503003EN
- Operating Altitude
- 6561.68 ft (2000 m) without derating
- Packaging Without Single Use Plastic
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Pep Verification Date
- 2026-03-23
- Psr Version
- PSR-0005-ed3-2023 06 06
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$67.75
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$67.75/ EA
Loading add to cart quantity...