Documentation & Downloads

Schneider Electric LC1K0910E7 TeSys K Contactor 3P 9A 48V AC Coil, 440V, 1NO Aux. Contact
- MPN: LC1K0910E7
- PPN: SCH-LC1K0910E7
CAD
$67.75
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Brazil, France, Indonesia
Complementary Attributes
- Irms Rated Making Capacity
- 110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
- Control Circuit Type
- AC 50/60 Hz
- Maximum Motor Phase Current
- 9 A
- Minimum Switching Current
- 5 mA for signalling circuit
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Associated Fuse Rating
- 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
- Electrical Durability
- 1.3 Mcycles 9 A AC-3 <= 440 V, 1.3 Mcycles 9 A AC-3e <= 440 V0.16 Mcycles 20 A AC-1 <= 690 V, 0.02 Mcycles 54 A AC-4 <= 440 V
- Insulation Resistance
- > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Motor Power Kw
- 4 kW 380...415 V AC 50/60 Hz AC-3e, 4 kW 440/690 V AC 50/60 Hz AC-3e4 kW 380...415 V AC 50/60 Hz AC-4, 4 kW 440/690 V AC 50/60 Hz AC-42.2 kW 220...230 V AC 50/60 Hz AC-34 kW 380...415 V AC 50/60 Hz AC-3, 4 kW 440/690 V AC 50/60 Hz AC-3, 2.2 kW 220...230 V AC 50/60 Hz AC-3e, 2.2 kW 220...230 V AC 50/60 Hz AC-4
- Protective Treatment
- TC IEC 60068, TC DIN 50016
- Utilisation Category
- AC-3, AC-3e, AC-1, AC-4
- [Icw] Rated Short-time Withstand Current
- 90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
- [Ith] Conventional Free Air Thermal Current
- 20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
- [Ue] Rated Operational Voltage
- power circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
- Carbon Footprint Of The Distribution Phase [A4]
- 0.35474462234016035, 0.4 kg CO2 eq.
- Carbon Footprint Of The Installation Phase [A5]
- 0 kg CO2 eq., 0.02438721956318318
- Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
- 57 kg CO2 eq., 56.65241524409137
- Local Publishable Date
- 2026-06-27
- Stocking Flag
- N
- Device Type
- LV equipment - LV contactor
- Traceability
- No
- Average Life Duration
- 20 year(s)
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Free of Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Free of Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant
- Rohs Eur Full Compliance Status
- Compliant
- With Recycled Cardboard
- Yes
- Product Contributes To Saved And Avoided Emissions
- No
- Tier
- 1
- Function Option
- Standard
- Average Impedance
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Compatibility Code
- LC1K
- Device Short Name
- LC1K
- Inrush Power In Va
- 30-30 VA (at 20 °C)
- Non Overlap Distance
- 0.5 mm
- Overvoltage Category
- III
- Product Availability
- Stock - Normally stocked in distribution facility
- Range
- TeSys
- Returnability
- Yes
- Software Version
- v6.2.4
- Total Lifecycle Carbon Footprint
- 58 kg CO2 eq.
- Pep Code
- ENVPEP1503003EN
- Pep Verification Date
- 2026-03-23
- Psr Version
- PSR-0005-ed3-2023 06 06
- Data Source
- extrapolated product
- Functional-unit Quantity
- 1
- Reference Lifetime In Y
- 20
- Energy Model - Installation [A5]
- No energy used
- Energy Model - End Of Life [C1-c4]
- Global, European and French datasets are used.
- Height Nominal
- 58 mm
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Nbr. Of Units In Pkg.
- 1
- Take-back
- No
- Customs Code
- 8536410045
Environment Attributes Main
- Take Back
- No
- Recycled Metal Content At Cr Level
- 0 %
- Toxic Heavy Metal Free
- Yes
- Carbon Footprint
- 58.208309019086165
- Environmental Disclosure
- ENVPEP1503003EN
- Operating Altitude
- 6561.68 ft (2000 m) without derating
- Packaging Without Single Use Plastic
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Pep Verification Date
- 2026-03-23
- Psr Version
- PSR-0005-ed3-2023 06 06
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$67.75
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$67.75/ EA
Loading add to cart quantity...