TeSys K Control Relay, 2NO+2NC, 120V AC Coil, 10 A, IP2X
TeSys K Control Relay, 2NO+2NC, 120V AC Coil, 10 A, IP2X
Schneider Electric

Schneider Electric CA2KN22G72 TeSys K Control Relay, 2NO+2NC, 120V AC Coil, 10 A, IP2X

  • MPN: CA2KN22G72
  • PPN: SCH-CA2KN22G72

CAD

$149.22

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides up to 120V AC coil with integral suppression device available, connection by spring terminals. For high operating rates until 180 cycles/min and ambient temperature -25/+50°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC), Sustainability compliant.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Indonesia, United States
Depth57 mm

Complementary Attributes

Control Circuit Voltage Limits
drop-out: 0.2...0.75 Uc (at <50 °C), operational: 0.8...1.15 Uc (at <50 °C)
Irms Rated Making Capacity
110 A IEC 60947
Minimum Switching Current
5 mA
Control Circuit TypeAC 50/60 Hz
Maximum Operating Rate10000 cyc/h
Minimum Switching Voltage17 V

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG conforming to IEC 60947, 10 A gG conforming to VDE 0660
Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6, vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, shocks contactor open10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
Operating Time
10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing, 15...25 ms coil de-energisation and NC closing, 5...15 ms coil energisation and NC opening
Utilisation Category
DC-13, AC-15
[Ue] Rated Operational Voltage
<= 690 V <= 400 Hz, <= 690 V <= 400 Hz<= 690 V <= 400 Hz, <= 690 V <= 400 Hz
Connections - Terminals
screw clamp terminals 2 0.34-1.5 mm²flexible without cable endscrew clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 2 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible with cable end, screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-1.5 mm²flexible with cable end
Carbon Footprint Of The End-of-life Phase [C1 To C4]
0.3 kg CO2 eq., 0.26049024039022145
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
0.9 kg CO2 eq., 0.9294198707245992
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
2
Serviceability
No
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1503003
Reach Full Compliance Status Id
NOT_CONTAINING_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
2448
China Rohs Label
1
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Compatibility Code
CA2K
Device Short Name
CA2K
Immunity To Microbreaks
2 ms
Insulation Resistance
> 10 MOhm> 10 MOhm
Non Overlap Distance
0.5 mm
Product Availability
Stock - Normally stocked in distribution facility
Product Or Component Type
control relay
Range
TeSys
Returnability
Yes
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage 21
120 V
Connections Terminals 55 Connections Terminals
screw clamp terminals
Database Version
2024-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unit
unit
Energy Consumption On Product Lifetime, In Kwh
219
Energy Model - Installation [A5]
No energy used
Energy Model - End Of Life [C1-c4]
Global, European and French datasets are used.
Height Nominal
58 mm
[Ith] Conventional Free Air Thermal Current
10 A (at 50 °C)
Hold-in Power Consumption In Va
4.5-4.5 VA (at 20 °C)
Package Weight(Lbs)
181.437 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Flame RetardanceV1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Mounting Supportplate, rail
Tightening Torque1.3 N.m screw clamp terminals flat Ø 6 mm, 1.3 N.m screw clamp terminals Philips No 2 6 mm, 1.3 N.m screw clamp terminals pozidriv No 2
Certificate AgencyCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
[Ui] Rated Insulation Voltage690 V IEC 60947, 750 V VDE 0110 group C, 690 V BS 5424, 600 V CSA C22.2 No 14
Carbon Footprint Of The Distribution Phase [A4]0.35870824940541357, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0.024659702463330477, 0 kg CO2 eq.
Carbon Footprint Of The Use Phase [B2, B3, B4, B6]89 kg CO2 eq., 88.5193988188928
Local Publishable Date2025-07-08
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Coil Technologybuilt-in bidirectional peak limiting diode suppressor
Contactor Applicationcontrol circuit
Heat Dissipation1.3-1.3 W
Inrush Power In Va30-30 VA (at 20 °C)
Mechanical Durability10 Mcycles
Pole Contact Composition2 NO + 2 NC
Product NameTeSys CAK
Protective TreatmentTC IEC 60068
Range Of ProductTeSys K control relay
Software Versionv6.2.4
Total Lifecycle Carbon Footprint90 kg CO2 eq.
Pole Contact Comp2 NO + 2 NC
Control Circuit Voltage 21 Control Circuit Voltage120 V
Pep CodeENVPEP1503003EN
Pep Verification Date2026-03-23
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime, In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; Europe, EU-27
Recyclability Potential, In %63
Width Nominal45 mm
[Uc] Control Circuit Voltage120 V AC 50/60 Hz
Nbr. Of Units In Pkg.1
Take-backNo

Environment Attributes Main

Ambient Air Temperature For Operation
-25-50 °C, -25-50 °C
Take Back
No
Recycled Metal Content At Cr Level
0 %
Toxic Heavy Metal Free
Yes
Carbon Footprint
90.09267688187637
Environmental Disclosure
ENVPEP1503003EN
Ip Degree Of Protection
IP2X
Packaging Made With Recycled Cardboard
Yes
Reach Free Of Svhc
Yes
Pep Code
ENVPEP1503003EN
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Ambient Air Temperature For Storage-50-80 °C, -50-80 °C
Reach Free ShvcYes
China Rohs RegulationX
Mercury FreeYes
Circularity ProfileENVEOLI1503003
Eu Rohs DirectiveCompliant
Operating Altitude6561.68 ft (2000 m) without derating
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-23
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Type
control relay
Range Of ProductTeSys K control relay

ETIM

ETIM 8
EC000196
ETIM 9EC000196

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months
Loading video…

Similar Products

Loading carousel layout...

CAD$149.22/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])