
Schneider Electric CA2KN40F7 TeSys K Control Relay 4P (4NO), 10A, 110V AC, Compact 45mm
- MPN: CA2KN40F7
- PPN: SCH-CA2KN40F7
- UNSPSC: 39122331
CAD
$128.12
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Description
Features
- This Schneider Electric industrial relay features a 4 NO (4 Normally Open) pole configuration, allowing you to control up to four independent electromagnetic loads or signaling circuits simultaneously. It eliminates the need for separate stacked modules, saving you valuable layout space inside overcrowded control automation panels.
- Engineered specifically for heavy-duty industrial environments, the integrated 110V AC 50/60Hz coil delivers swift, repeatable switching execution. This tailored control voltage prevents drops and functional anomalies in common facility panels, drops right into existing industrial control loops, and handles power fluctuations seamlessly.
- Designed with a highly compact 45mm width, this TeSys K model features dual-purpose mounting support for simple clipping onto a 35mm DIN rail or secure direct fixing by screw onto a panel backplate. It minimizes your physical installation footprint without forcing you to re-drill or restructure your existing sub-panels.
- With a rated mechanical durability of 10 million cycles and an outstanding operational rate of up to 10,000 cycles per hour, this control relay is optimized for demanding AC-15 and DC-13 utilization categories. This industrial-grade endurance minimizes system downtime and reduces maintenance overhead in continuous-duty manufacturing processes.
- Fully certified under CSA C22.2 No 60947-5-1, UL, CE, and UKCA standards, this Schneider Electric device meets the stringent safety and regulatory requirements of Canadian industrial electrical codes. It offers peace of mind during commercial safety inspections and ensures absolute electrical containment with an integrated IP2X touch-safe terminal rating.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Indonesia, United States |
|---|---|
| Depth | 57 mm |
| Weight | 179 g |
|---|
Complementary Attributes
| Ue Rated Operational Voltage | <= 690 V <= 400 Hz, <= 690 V <= 400 Hz<= 690 V <= 400 Hz, <= 690 V <= 400 Hz, <= 690 V <= 400 Hz, <= 690 V <= 400 Hz<= 690 V <= 400 Hz, <= 690 V <= 400 Hz |
|---|---|
| Control Circuit Type | AC 50/60 Hz |
| Irms Rated Making Capacity | 110 A IEC 60947 |
| Minimum Switching Current | 5 mA |
| Uc Control Circuit Voltage | 110 V AC 50/60 Hz |
| Ui Rated Insulation Voltage | 690 V IEC 60947750 V VDE 0110 group C, 690 V BS 5424600 V CSA C22.2 No 14 |
|---|---|
| Control Circuit Voltage Limits | drop-out: 0.2...0.75 Uc (at <50 °C)operational: 0.8...1.15 Uc (at <50 °C) |
| Maximum Operating Rate | 10000 cyc/h |
| Minimum Switching Voltage | 17 V |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 10 A gG conforming to IEC 60947, 10 A gG conforming to VDE 0660 |
| Insulation Resistance | > 10 MOhm> 10 MOhm, > 10 MOhm> 10 MOhm |
| Mounting Support | rail, plate |
| Tightening Torque | 1.3 N.m screw clamp terminals flat Ø 6 mm1.3 N.m screw clamp terminals Philips No 2 6 mm, 1.3 N.m screw clamp terminals pozidriv No 2 |
| Connections Terminals | screw clamp terminals 2 0.34-1.5 mm²flexible without cable end, screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 2 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible with cable end, screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-1.5 mm²flexible with cable end |
| Carbon Footprint Of The Distribution Phase A4 | 0.35474462234016035, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 | 0 kg CO2 eq., 0.02438721956318318 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 58 kg CO2 eq., 57.502201472752766 |
| Local Publishable Date | 2026-06-27 |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Compatibility Code | CA2K |
| Device Short Name | CA2K |
| Immunity To Microbreaks | 2 ms |
| Mechanical Durability | 10 Mcycles |
| Pole Contact Composition | 4 NO |
| Product Name | TeSys CAK |
| Protective Treatment | TC IEC 60068 |
| Range Of Product | TeSys K control relay |
| Software Version | v6.2.4 |
| Total Lifecycle Carbon Footprint | 59 kg CO2 eq. |
| Pole Contact Comp | 4 NO |
| Control Circuit Voltage 21 Control Circuit Voltage | 110 V |
| Database Version | 2024-01 |
| Height Nominal | 58 mm |
| Nbr. Of Units In Pkg. | 1 |
| Ith Conventional Free Air Thermal Current | 10 A (at 50 °C) |
| Warranty In Months | 18 |
| Functional Unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Recyclability Potential In % | 63 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Flame Retardance | V1 conforming to UL 94requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102 |
| Mechanical Robustness | vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, shocks contactor open10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed15 Gn for 11 ms IEC 60068-2-27 |
| Operating Time | 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing |
| Utilisation Category | DC-13, AC-15 |
| Certificate Agency | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 0.25761189519253946, 0.3 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 0.9 kg CO2 eq., 0.9191500378989131 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Serviceability | No |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1503003 |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 2448 |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Contactor Application | control circuit |
| Heat Dissipation | 1.3-1.3 W |
| Inrush Power In Va | 30-30 VA (at 20 °C) |
| Non Overlap Distance | 0.5 mm |
| Product Availability | Stock - Normally stocked in distribution facility |
| Product Or Component Type | control relay |
| Range | TeSys |
| Returnability | Yes |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Control Circuit Voltage 21 | 110 V |
| Connections Terminals 55 Connections Terminals | screw clamp terminals |
| Data Source | extrapolated product |
| Width Nominal | 45 mm |
| Customs Code | 8536490075 |
| Hold In Power Consumption In Va | 4.5-4.5 VA (at 20 °C) |
| Functional Unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional Unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 142.2624 |
Environment Attributes Main
| Ambient Air Temperature For Operation | -25-50 °C, -25-50 °C, -25-50 °C, -25-50 °C |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 59.05809524774756 |
| Environmental Disclosure | ENVPEP1503003EN |
| Ip Degree Of Protection | IP2X |
| Packaging Made With Recycled Cardboard | Yes |
| Reach Free Of Svhc | Yes |
| Pep Code | ENVPEP1503003EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Ambient Air Temperature For Storage | -50-80 °C, -50-80 °C, -50-80 °C, -50-80 °C |
|---|---|
| Reach Free Shvc | Yes |
| China Rohs Regulation | X |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1503003 |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 6561.68 ft (2000 m) without derating |
| Packaging Without Single Use Plastic | Yes |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-23 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
General Attributes
| Product Or Component Type | control relay |
|---|
| Range Of Product | TeSys K control relay |
|---|
ETIM
| ETIM 8 | EC000196 |
|---|---|
| ETIM 10 | EC000196 |
| ETIM 9 | EC000196 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|


Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$128.12
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
CAD$128.12/ EA
Loading add to cart quantity...












