Schneider Electric REL52920 Arc Protection Relay, PowerLogic A3 F6P 6 point sensors 4 control arc device
- MPN: REL52920
- PPN: SCH-REL52920
- UNSPSC: 39121637
CAD
$1913.17
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Description
Features
- Arc flash mitigation protection
- Multi-zone detection to isolate correspondant circuit
- Extendable solution by bus connection to A3 devices
- Multiple mechanical mounting to adapt to cubicle
- Multiple configuration with rotary switches
- High speed outputs for faster tripping
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Latvia |
|---|
| Weight | 1140 g |
|---|
Complementary Attributes
| Us Rated Supply Voltage | 24...240 V AC/DC |
|---|
Important Information Attributes
| Electromagnetic Compatibility | emission tests IEC/EN 60255-26 ed. 3emission tests class A EN 55022, emission tests CISPR 22, emission tests class A EN 55011, emission tests IEC 60255-25, emission tests CISPR 11EMC immunity A IEC/EN 60255-26 ed. 3damped oscillatory wave EN/IEC 61000-4-18, electrostatic discharge level 4 EN/IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3electrical fast transient level 4 EN/IEC 61000-4-4surge immunity test level 3 EN/IEC 61000-4-5immunity to conducted interference caused by radio-electrical fields level 3 EN/IEC 61000-4-6immunity to magnetic fields EN/IEC 61000-4-8immunity to magnetic fields level 5 EN/IEC 61000-4-9, immunity to voltage dips power lines (DC) EN/IEC 61000-4-29, immunity to voltage dips EN/IEC 61000-4-11immunity to ripple EN/IEC 61000-4-17 |
|---|---|
| Protection Type | 50ARC, arc suppression |
| Carbon Footprint Of The Distribution Phase A4 | 0.321963748211385, 0.3 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 | 0.31397050040511143, 0.3 kg CO2 eq. |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 420 kg CO2 eq., 419.83 |
| Local Publishable Date | 2026-08-25 |
| Return Indicator | Y |
| Serviceability | Yes |
| Field Service Division | DPIBS |
| Weee Scope | Out |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Reference contains Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant By Exemption |
| Rohs Eur Full Compliance Status | Compliant By Exemption |
| China Rohs Label | 5 |
| Without Single Use Plastic | No |
| Product Kit Identifier | N |
| Device Short Name | A3-F6P |
| Energy Efficiency Optimized | False |
| Output Current Limits | 20 mA 24 V DC |
| Product Name | PowerLogic Arc |
| Protective Treatment | conformal coating |
| Relay Application | arc flash |
| Software Version | v5.9.4 |
| Sustainable Packaging | No |
| Type Of Measurement | arc |
| Database Version | 2022-01 |
| Height Nominal | total: 135 mm |
| Nbr. Of Units In Pkg. | 1 |
| Warranty In Months | 18 |
| Functional Unit Quantity | 1 |
| Reference Lifetime In Y | 10 |
| Environmental Characteristic | exposure to dry heat Bd EN/IEC 60068-2-2, exposure to cold Ad EN/IEC 60068-2-1, exposure to damp heat in service Db EN/IEC 60068-2-30exposure to damp heat in service Cab EN/IEC 60068-2-78, temperature variation Nb IEC 60068-2-14 |
|---|---|
| Certificate Agency | EN/IEC 60255-1, EN 60255-27 |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 2 kg CO2 eq., 2.190713214074208 |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 76 kg CO2 eq., 76.28452681603325 |
| Local Data Status | Publishable |
| Pre Comm Date | 2023-03-27 |
| Device Type | Relay, Control & Measurement - Protection relay |
| Traceability | Yes |
| Use Carbon Footprint | 419.83 |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI2303035_V3 |
| Reach Full Compliance Status Id | CONTAINS_SVHC |
| Rohs Eur In Scope | No |
| Rohs Eur Conformity Date | 2320 |
| China Rohs In Scope | Yes |
| With Recycled Cardboard | No |
| Product Contributes To Saved And Avoided Emissions | No |
| Control And Monitoring Type | switchgear internal arc detection |
| Display Type | LED 12 |
| Mechanical Robustness | vibrations class 2) IEC 60255-21-1shocks class 2) IEC 60255-21-2earthquakes criteria A) level 2 IEC 60255-21-3vibrations Fc) IEC 60068-2-6shocks Ea) IEC 60068-2-27 |
| Product Availability | Stock - Normally stocked in distribution facility |
| Product Or Component Type | arc fault detection device |
| Range | PowerLogic |
| Returnability | Yes |
| Supply | Power over Ethernet (PoE) |
| Total Lifecycle Carbon Footprint | 79 kg CO2 eq. |
| Connections Terminals | removable screw terminal block |
| Data Source | extrapolated product |
| Width Nominal | total: 70 mm |
| Customs Code | 8536490080 |
| Functional Unit Description | To reduce the Arc flash ignition inside medium voltage or low voltage cubicles, the device detect the light with the help of light sensors and should act very fast on the appropriate switching device during 10 years. The device can get the light detection also from other devices through fast bus.& 10Uaux = 24-240Vac/dc& 10Maximum withstand voltage = 264 V ac/dc& 10Passive Power over Ethernet (PoE) = 24 V dc& 10Normal operating power consumption = 6 W; (Max. 9 W)& 10Typical operation time = 2 ms& 10The product is in accordance with the IEC 62271-200 standard and IP20 in accordance with the standard IEC 60529. |
| Functional Unit Unit | Unit |
| Recyclability Potential In % | 60 |
Environment Attributes Main
| Ambient Air Temperature For Operation | -40-65 °C, -40-65 °C |
|---|---|
| Operating Altitude | <= 6561.68 ft (2000 m), <= 6561.68 ft (2000 m) |
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI2303035_V3 |
| Eu Rohs Directive | Compliant By Exemption |
| Packaging Made With Recycled Cardboard | No |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Pep Code | ENVPEP2303035EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent external review |
| Ambient Air Temperature For Storage | -40-80 °C, -40-80 °C |
|---|---|
| Take Back | No |
| China Rohs Regulation | X |
| Carbon Footprint | 79.11117427872395 |
| Environmental Disclosure | ENVPEP2303035EN |
| Ip Degree Of Protection | IP20 conforming to IEC 60529 |
| Packaging Without Single Use Plastic | No |
| Relative Humidity | 0-95 % without condensation |
| Pep Verification Date | 2023-07-01 |
| Psr Version | PSR-0005-ed2-2016 03 29 |
General Attributes
| Product Or Component Type | arc fault detection device |
|---|
ETIM
| ETIM 8 | EC002911 |
|---|---|
| ETIM 10 | EC002911 |
| ETIM 9 | EC002911 |
|---|
Output Attributes
| Number Of Outputs | 4 digital3 control relay |
|---|
Input Attributes
| Discrete Input Voltage | 24...240 V AC/DC 250 V) |
|---|
| Number Of Inputs | 6 arc sensor |
|---|



Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$1913.17
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
CAD$1913.17/ EA
Loading add to cart quantity...