Documentation & Downloads

Schneider Electric LUCC32FU TeSys Ultra Advanced Control Unit, 1-Phase, 8-32A, IP20, 110-240V AC/DC
- MPN: LUCC32FU
- PPN: SCH-LUCC32FU
CAD
$284.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
Description
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Brazil, France
Complementary Attributes
- Control Circuit Voltage Limits
- 55 V DC 110...220 V drop-out88...264 V AC 110...240 V in operation, 88...242 V DC 110...220 V in operation, 55 V AC 110...240 V drop-out
Important Information Attributes
- Device Application
- motor control, motor protection
- Function Available
- protection against overload and short-circuit, protection against phase failure and phase imbalance, manual reset, earth fault protection
- Operating Time
- 50 ms closing with LUB38 control circuit35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 50 ms closing with LUB32 control circuit
- Resistance To Fast Transients
- 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
- Shock Resistance
- 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
- Typical Current Consumption
- 280 mA 110...220 V DC I maximum while closing with LUB38, 25 mA 110...240 V AC I rms sealed with LUB38, 25 mA 110...220 V DC I rms sealed with LUB32, 25 mA 110...220 V DC I rms sealed with LUB38, 280 mA 110...240 V AC I maximum while closing with LUB32, 280 mA 110...240 V AC I maximum while closing with LUB38, 280 mA 110...220 V DC I maximum while closing with LUB32, 25 mA 110...240 V AC I rms sealed with LUB32
- Vibration Resistance
- 2 gn 5-300 Hz power poles open IEC 60068-2-6, 4 gn 5-300 Hz power poles closed IEC 60068-2-6
- [Uc] Control Circuit Voltage
- 110...240 V AC, 110...220 V DC
- Non-dissipating Shock Wave
- 1 kV serial mode IEC 60947-6-2, 2 kV common mode IEC 60947-6-2
- Carbon Footprint Of The End-of-life Phase [C1 To C4]
- 0.3105239177860554, 0.3 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase [A1 To A3]
- 1 kg CO2 eq., 1.18537983562319
- Local Data Status
- Publishable
- Return Indicator
- Y
- Stock Policy
- 2
- Serviceability
- No
- Field Service Division
- PPIBS
- Weee Applicability
- Finished product
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Reference contains Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Reference contains Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant By Exemption
- Rohs Eur Full Compliance Status
- Compliant By Exemption
- China Rohs Label
- 7
- Without Single Use Plastic
- Yes
- Product Kit Identifier
- N
- Device Short Name
- LUCC
- Fixing Mode
- plug-in (front face)
- Immunity To Radioelectric Fields
- 10 V IEC 61000-4-6
- Load Type
- single-phase motor
- Network Frequency
- 40...60 Hz
- Product Name
- TeSys Ultra
- Product Specific Application
- basic protection and advanced functions, communication
- Range
- TeSys
- Reset
- manual reset
- Returnability
- Yes
- Sustainable Packaging
- Yes
- Total Lifecycle Carbon Footprint
- 20 kg CO2 eq.
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Control Circuit Voltage 3 Control Circuit Voltage
- 110...220 V
- Load Type 6 Load Type
- single-phase motor
- Database Version
- 2023-02
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
- Functional-unit Description
- Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime, In Kwh
- 273.75
- Energy Model - Installation [A5]
- Electricity Mix; Low voltage; 2018; France, FR
- Energy Model - End Of Life [C1-c4]
- Electricity Mix; Low voltage; 2018; France, FR
- Height Nominal
- 66 mm
- [Ue] Rated Operational Voltage
- 690 V AC
- Halogen-free Status
- Halogen free plastic parts product
- Package Weight(Lbs)
- 127.0 g
- Warranty (In Months)
- 18
Environment Attributes Main
- Ambient Air Temperature For Storage
- -40-85 °C, -40-85 °C
- Product Compatibility
- power base LUB32, power base LUB38, power base LUB320, power base LUB380, reversing contactor breaker LU2B32FU, reversing contactor breaker LU2B38FU
- Halogene Performance
- Halogen free plastic parts product
- China Rohs Regulation
- X
- Carbon Footprint
- 19.86366113089625
- Circularity Profile
- ENVEOLI2406038EN
- Eu Rohs Directive
- Compliant By Exemption
- Operating Altitude
- 6561.68 ft (2000 m)
- Packaging Without Single Use Plastic
- Yes
- Pep Code
- ENVPEP2406038EN
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
General Attributes
- Product Or Component Type
- advanced control unit
ETIM
- ETIM 8
- EC000617
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$284.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$284.98/ EA
Loading add to cart quantity...